Calibration of phase contrast imaging on HL-2A Tokamak

Phase contrast imaging (PCI) has recently been developed on HL-2A tokamak. In this article we present the calibration of this diagnostic. This system is to diagnose chord integral density fluctuations by measuring the phase shift of a CO2 laser beam with a wavelength of 10.6 μm when the laser beam p...

Full description

Saved in:
Bibliographic Details
Published inJournal of instrumentation Vol. 12; no. 10; p. C10005
Main Authors Yu, Y., Gong, S.B., Xu, M., Xiao, C.J., Jiang, W., Zhong, W.L., Shi, Z.B., Wang, H.J., Wu, Y.F., Yuan, B.D., Lan, T., Ye, M.Y., Duan, X.R.
Format Journal Article
LanguageEnglish
Published Bristol IOP Publishing 16.10.2017
Subjects
Online AccessGet full text

Cover

Loading…
Abstract Phase contrast imaging (PCI) has recently been developed on HL-2A tokamak. In this article we present the calibration of this diagnostic. This system is to diagnose chord integral density fluctuations by measuring the phase shift of a CO2 laser beam with a wavelength of 10.6 μm when the laser beam passes through plasma. Sound waves are used to calibrate PCI diagnostic. The signal series in different PCI channels show a pronounced modulation of incident laser beam by the sound wave. Frequency-wavenumber spectrum is achieved. Calibrations by sound waves with different frequencies exhibit a maximal wavenumber response of 12 cm−1. The conversion relationship between the chord integral plasma density fluctuation and the signal intensity is 2.3×1013 m−2/mV, indicating a high sensitivity.
AbstractList Phase contrast imaging (PCI) has recently been developed on HL-2A tokamak. In this article we present the calibration of this diagnostic. This system is to diagnose chord integral density fluctuations by measuring the phase shift of a CO2 laser beam with a wavelength of 10.6 μm when the laser beam passes through plasma. Sound waves are used to calibrate PCI diagnostic. The signal series in different PCI channels show a pronounced modulation of incident laser beam by the sound wave. Frequency-wavenumber spectrum is achieved. Calibrations by sound waves with different frequencies exhibit a maximal wavenumber response of 12 cm−1. The conversion relationship between the chord integral plasma density fluctuation and the signal intensity is 2.3×1013 m−2/mV, indicating a high sensitivity.
Author Yu, Y.
Wang, H.J.
Lan, T.
Zhong, W.L.
Duan, X.R.
Xiao, C.J.
Wu, Y.F.
Ye, M.Y.
Gong, S.B.
Jiang, W.
Shi, Z.B.
Yuan, B.D.
Xu, M.
Author_xml – sequence: 1
  givenname: Y.
  surname: Yu
  fullname: Yu, Y.
– sequence: 2
  givenname: S.B.
  surname: Gong
  fullname: Gong, S.B.
– sequence: 3
  givenname: M.
  surname: Xu
  fullname: Xu, M.
– sequence: 4
  givenname: C.J.
  surname: Xiao
  fullname: Xiao, C.J.
– sequence: 5
  givenname: W.
  surname: Jiang
  fullname: Jiang, W.
– sequence: 6
  givenname: W.L.
  surname: Zhong
  fullname: Zhong, W.L.
– sequence: 7
  givenname: Z.B.
  surname: Shi
  fullname: Shi, Z.B.
– sequence: 8
  givenname: H.J.
  surname: Wang
  fullname: Wang, H.J.
– sequence: 9
  givenname: Y.F.
  surname: Wu
  fullname: Wu, Y.F.
– sequence: 10
  givenname: B.D.
  surname: Yuan
  fullname: Yuan, B.D.
– sequence: 11
  givenname: T.
  surname: Lan
  fullname: Lan, T.
– sequence: 12
  givenname: M.Y.
  surname: Ye
  fullname: Ye, M.Y.
– sequence: 13
  givenname: X.R.
  surname: Duan
  fullname: Duan, X.R.
BookMark eNpNkE9PwzAMxSM0JLbBV0CVOJfaSdo0x6kChlSJyzhHaZuO7k9Sku7At6dVJ8TJlt9Ptt9bkYV11hDyiPCMkOcJCp7HQCkmSBOEpEAASG_I8k9Y_OvvyCqEwwjIlMOSZIU-dZXXQ-ds5Nqo_9LBRLWzg9dhiLqz3nd2H43itozpJtq5oz7r4z25bfUpmIdrXZPP15ddsY3Lj7f3YlPGNc3ZELMGELCRwoiGNSyTXNC64VBBRZFVTBttUk7TmnLJec4ppFixFhiTrZEC2Jo8zXt7774vJgzq4C7ejicVZVmaSUQhRyqbqdq7ELxpVe_Hz_2PQlBTRmqyryb7Cuk0nDNiv4h_WE8
CitedBy_id crossref_primary_10_1016_j_fusengdes_2018_06_003
crossref_primary_10_1007_s10894_021_00302_8
crossref_primary_10_1016_j_fusengdes_2017_11_022
crossref_primary_10_1088_1748_0221_13_10_P10016
Cites_doi 10.1063/1.4893427
10.1063/1.2222333
10.1109/27.310636
10.1063/1.4745613
10.1088/0741-3335/54/12/124029
10.1063/1.4960761
10.1063/1.2228623
10.1063/1.2968266
10.1063/1.1140193
10.1063/1.859023
10.1063/1.4871392
10.1088/0741-3335/52/12/124025
10.1063/1.870934
10.1063/1.1947447
10.1016/S0031-8914(42)80035-X
10.1063/1.874014
10.1063/1.3065094
10.1063/1.4884903
10.1088/0029-5515/55/9/093004
10.1016/S0031-8914(42)80079-8
ContentType Journal Article
Copyright Copyright IOP Publishing Oct 2017
Copyright_xml – notice: Copyright IOP Publishing Oct 2017
CorporateAuthor HL-2A team
CorporateAuthor_xml – name: HL-2A team
DBID AAYXX
CITATION
7U5
8FD
L7M
DOI 10.1088/1748-0221/12/10/C10005
DatabaseName CrossRef
Solid State and Superconductivity Abstracts
Technology Research Database
Advanced Technologies Database with Aerospace
DatabaseTitle CrossRef
Technology Research Database
Advanced Technologies Database with Aerospace
Solid State and Superconductivity Abstracts
DatabaseTitleList Technology Research Database
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISSN 1748-0221
EndPage C10005
ExternalDocumentID 10_1088_1748_0221_12_10_C10005
GroupedDBID 1JI
5B3
5GY
5PX
5VS
5ZH
7.M
7.Q
AAGCD
AAGID
AAJIO
AAJKP
AALHV
AATNI
AAYXX
ABCXL
ABJNI
ABQJV
ABVAM
ACAFW
ACGFO
ACGFS
ACHIP
ADWVK
AEFHF
AENEX
AFYNE
AKPSB
ALMA_UNASSIGNED_HOLDINGS
AOAED
ASPBG
ATQHT
AVWKF
AZFZN
CBCFC
CEBXE
CITATION
CJUJL
CRLBU
CS3
DU5
EBS
EDWGO
EMSAF
EPQRW
EQZZN
HAK
IJHAN
IOP
IZVLO
KOT
LAP
M45
MV1
N5L
N9A
NT-
NT.
PJBAE
RIN
RNS
ROL
RPA
SY9
VSI
W28
ZMT
7U5
8FD
L7M
ID FETCH-LOGICAL-c283t-3d0101d97e7d3d369472cd40b0b213b3aeae5425c24944842051b3f0339fe9703
ISSN 1748-0221
IngestDate Thu Oct 10 17:48:49 EDT 2024
Fri Aug 23 01:25:38 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 10
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c283t-3d0101d97e7d3d369472cd40b0b213b3aeae5425c24944842051b3f0339fe9703
PQID 2365691179
PQPubID 4562433
ParticipantIDs proquest_journals_2365691179
crossref_primary_10_1088_1748_0221_12_10_C10005
PublicationCentury 2000
PublicationDate 2017-10-16
PublicationDateYYYYMMDD 2017-10-16
PublicationDate_xml – month: 10
  year: 2017
  text: 2017-10-16
  day: 16
PublicationDecade 2010
PublicationPlace Bristol
PublicationPlace_xml – name: Bristol
PublicationTitle Journal of instrumentation
PublicationYear 2017
Publisher IOP Publishing
Publisher_xml – name: IOP Publishing
References T. Ido . (8) 2010; 52
11
22
12
13
14
15
17
18
H.G. Shen . (6) 2015; 55
1
2
S.B. Gong . (19) 2017
3
4
5
7
A. Mazurenko (23) 2001
9
M. Porkolab . (16) 2012; 54
D. Gray ed. (20) 1972
10
21
References_xml – year: 1972
  ident: 20
  publication-title: American Institute of Physics Handbook
  contributor:
    fullname: D. Gray ed.
– issn: 0920-3796
  year: 2017
  ident: 19
  publication-title: Fusion; Eng. Design
  contributor:
    fullname: S.B. Gong .
– ident: 9
  doi: 10.1063/1.4893427
– ident: 17
  doi: 10.1063/1.2222333
– ident: 7
  doi: 10.1109/27.310636
– ident: 22
  doi: 10.1063/1.4745613
– year: 2001
  ident: 23
  contributor:
    fullname: A. Mazurenko
– volume: 54
  start-page: 124029
  year: 2012
  ident: 16
  publication-title: Plasma Phys. Control. F.
  doi: 10.1088/0741-3335/54/12/124029
  contributor:
    fullname: M. Porkolab .
– ident: 10
  doi: 10.1063/1.4960761
– ident: 15
  doi: 10.1063/1.2228623
– ident: 18
  doi: 10.1063/1.2968266
– ident: 13
  doi: 10.1063/1.1140193
– ident: 3
  doi: 10.1063/1.859023
– ident: 21
  doi: 10.1063/1.4871392
– volume: 52
  start-page: 124025
  year: 2010
  ident: 8
  publication-title: Plasma Phys. Control. F.
  doi: 10.1088/0741-3335/52/12/124025
  contributor:
    fullname: T. Ido .
– ident: 1
  doi: 10.1063/1.870934
– ident: 4
  doi: 10.1063/1.1947447
– ident: 11
  doi: 10.1016/S0031-8914(42)80035-X
– ident: 2
  doi: 10.1063/1.874014
– ident: 14
  doi: 10.1063/1.3065094
– ident: 5
  doi: 10.1063/1.4884903
– volume: 55
  start-page: 093004
  issn: 0029-5515
  year: 2015
  ident: 6
  publication-title: Nucl. Fusion
  doi: 10.1088/0029-5515/55/9/093004
  contributor:
    fullname: H.G. Shen .
– ident: 12
  doi: 10.1016/S0031-8914(42)80079-8
SSID ssj0059540
Score 2.2118046
Snippet Phase contrast imaging (PCI) has recently been developed on HL-2A tokamak. In this article we present the calibration of this diagnostic. This system is to...
SourceID proquest
crossref
SourceType Aggregation Database
StartPage C10005
SubjectTerms Calibration
Carbon dioxide
Carbon dioxide lasers
Diagnostic systems
Integrals
Laser beams
Lasers
Microscopes
Phase contrast
Plasma
Plasma density
Sound waves
Tokamak devices
Variations
Wavelengths
Title Calibration of phase contrast imaging on HL-2A Tokamak
URI https://www.proquest.com/docview/2365691179
Volume 12
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LT8MwDI5gXOCAeIrBQD1wm9J1SZ_HMYEG4iWxSeNUJW0qpmkPsXHh1-OkTZfBQMClat3KreKvn53UdhE6BxfoBZwIzMF9YYhvHcx4SjDhfuZlaSA7pshsi3u_03Nv-l5_kRKkqkvm3E7eV9aV_MeqIAO7yirZP1i2VAoC2Af7whYsDNtf2VgWVvHXMuibvjCdfM5m8_pgVPyBaFzv3GLSqncnQzZiw2_i0YHqJTsqapFKzDy_KZa2y0SdIof3yb4oZX11zd3ieMDyFVj7xjaXFcBVySwN32DCwA0xOPjc8GKFTNMnMWHiGGTYlt8OPMO1LgRfiBvITq4h6BvIfaIWFWSbYEOP2S_7kx8rswvVd_UwjKW2WGqLmwQkca5nHW0QICXJhtcPj9pre5Gni2fzJ9DV5GHYKGWNJoGHbeR6lgOZZT-ugpPuDtourGi1cojsojUx3kNbRq_JfeQbYLEmmaXAYmmwWAVYLDipwGIVYDlAvavLbruDi59m4AQixTmmqewamEaBCFKaUj9yA5KkrsMdTpqUUyaY8ICoE5h3w9TcJcDKnGYOpVEmIuD_Q1QZT8biCFmJkzmM8YRyiOtTP-Byrk956LoscSkRVdTQIxBP894o8c9jX0U1PVBx8R7NYkJhThHJ1oTHf1Z4gjYX4K2hCrwn4hSixDk_U-b9AIihVoc
link.rule.ids 315,783,787,27936,27937
linkProvider IOP Publishing
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Calibration+of+phase+contrast+imaging+on+HL-2A+Tokamak&rft.jtitle=Journal+of+instrumentation&rft.au=Yu%2C+Y.&rft.au=Gong%2C+S.B.&rft.au=Xu%2C+M.&rft.au=Xiao%2C+C.J.&rft.date=2017-10-16&rft.issn=1748-0221&rft.eissn=1748-0221&rft.volume=12&rft.issue=10&rft.spage=C10005&rft.epage=C10005&rft_id=info:doi/10.1088%2F1748-0221%2F12%2F10%2FC10005&rft.externalDBID=n%2Fa&rft.externalDocID=10_1088_1748_0221_12_10_C10005
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1748-0221&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1748-0221&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1748-0221&client=summon