New progress on beam availability and reliability of PKU high intensity CW proton ECR ion source
The stability and reliability of an ion source and its beam availability are extremely significant for any accelerator,especially for those high current long term CW operation ones like ADS. Although the first high quality 306-hours continuous wave(CW) operating curve at 50 m A@35 ke V has been succ...
Saved in:
Published in | Chinese physics B Vol. 26; no. 2; pp. 345 - 348 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
01.02.2017
|
Subjects | |
Online Access | Get full text |
ISSN | 1674-1056 2058-3834 |
DOI | 10.1088/1674-1056/26/2/025206 |
Cover
Abstract | The stability and reliability of an ion source and its beam availability are extremely significant for any accelerator,especially for those high current long term CW operation ones like ADS. Although the first high quality 306-hours continuous wave(CW) operating curve at 50 m A@35 ke V has been successfully obtained with a standard compact 2.45 GHz ECR ion source at Peking University(PKU), but the uncertainties that caused beam trips before are unacceptable during an accelerator real operation and should be eliminated. Meanwhile, no permission will be given when the beam power is upgraded from 50 m A@35 ke V to 50 m A@50 ke V. To improve the PKU CW proton source quality, several upgrades were done recently. After those improvements, a new long term CW proton beam experiment at 50 m A@50 ke V was carried out in June 2016. The total running time is 300.5 hours, including near 6 hours ion source preparation and 294 hours non-disturb continuous operation. Within the continuous 13 days operation, no beam-off happened, no spark was observed,no beam drop appeared, no interrupting action was needed, and only a few beam fluctuations caused by the air conditional failure occurred. Beam availability and reliability within the 294 hours is 100%. The root-mean-square(RMS) emittance of this 50 m A@50 ke V CW proton beam is about 0.186 π.mm.mrad. A careful inspection of the ion source was done after this long term operation and no obvious damage was found. The restart experimental results obtained after the ion source inspection prove the high repeatability of PKU PMECRIS. In addition, a 130-m A H+beam was obtained at 50 k V with duty factor of 10%(100 Hz/1 ms) with this source. Details will be presented in this paper. |
---|---|
AbstractList | The stability and reliability of an ion source and its beam availability are extremely significant for any accelerator,especially for those high current long term CW operation ones like ADS. Although the first high quality 306-hours continuous wave(CW) operating curve at 50 m A@35 ke V has been successfully obtained with a standard compact 2.45 GHz ECR ion source at Peking University(PKU), but the uncertainties that caused beam trips before are unacceptable during an accelerator real operation and should be eliminated. Meanwhile, no permission will be given when the beam power is upgraded from 50 m A@35 ke V to 50 m A@50 ke V. To improve the PKU CW proton source quality, several upgrades were done recently. After those improvements, a new long term CW proton beam experiment at 50 m A@50 ke V was carried out in June 2016. The total running time is 300.5 hours, including near 6 hours ion source preparation and 294 hours non-disturb continuous operation. Within the continuous 13 days operation, no beam-off happened, no spark was observed,no beam drop appeared, no interrupting action was needed, and only a few beam fluctuations caused by the air conditional failure occurred. Beam availability and reliability within the 294 hours is 100%. The root-mean-square(RMS) emittance of this 50 m A@50 ke V CW proton beam is about 0.186 π.mm.mrad. A careful inspection of the ion source was done after this long term operation and no obvious damage was found. The restart experimental results obtained after the ion source inspection prove the high repeatability of PKU PMECRIS. In addition, a 130-m A H+beam was obtained at 50 k V with duty factor of 10%(100 Hz/1 ms) with this source. Details will be presented in this paper. |
Author | 彭士香 张艾霖 任海涛 徐源 张滔 张景丰 温佳美 郭之虞 陈佳洱 |
AuthorAffiliation | SKLNPT & IHIP, School of Physics, Peking University, Beijing 100871, China University of Chinese Academy of Sciences, Beijing 100049, China |
Author_xml | – sequence: 1 fullname: 彭士香 张艾霖 任海涛 徐源 张滔 张景丰 温佳美 郭之虞 陈佳洱 |
BookMark | eNqFkN9LwzAQx4NMcE7_BCH4XndNmjTDJxnzBw4VcfhYkzTtIl06k6rsvzdlcw--CAfHHff93t3nGA1c6wxCZylcpCDEOOV5lqTA-JjEGANhBPgBGhJgIqGCZgM03M8coeMQ3gF4CoQO0duD-cZr39behIBbh5WRKyy_pG2kso3tNli6EnvT2N-6rfDT_QIvbb3E1nXGhb47fe1tuugwmz5jG3NoP702J-iwkk0wp7s8Qovr2cv0Npk_3txNr-aJJgK6hGbCyFypSmkOMtdK8lJlWZVDWWlClBSEA9VcTxQBzYxiihFKeEZBgeAlHSG29dW-DcGbqlh7u5J-U6RQ9JiKHkHRIyhIjGKLKeou_-i07WQXH-h8hPCv-nynXrau_rCu3q_leUoYm8SrfwAvBXt3 |
CitedBy_id | crossref_primary_10_1007_s11433_017_9130_3 crossref_primary_10_1063_1_5128522 crossref_primary_10_1088_1748_0221_17_06_P06032 crossref_primary_10_1063_5_0098645 crossref_primary_10_1063_1_5128019 crossref_primary_10_1007_s41605_023_00423_y crossref_primary_10_1088_1748_0221_18_10_P10038 |
Cites_doi | 10.1063/1.3266145 10.1063/1.4738635 10.1063/1.4932399 |
ContentType | Journal Article |
DBID | 2RA 92L CQIGP ~WA AAYXX CITATION |
DOI | 10.1088/1674-1056/26/2/025206 |
DatabaseName | 维普期刊资源整合服务平台 中文科技期刊数据库-CALIS站点 中文科技期刊数据库-7.0平台 中文科技期刊数据库- 镜像站点 CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Physics |
DocumentTitleAlternate | New progress on beam availability and reliability of PKU high intensity CW proton ECR ion source |
EISSN | 2058-3834 |
EndPage | 348 |
ExternalDocumentID | 10_1088_1674_1056_26_2_025206 671255960 |
GroupedDBID | 02O 1JI 1WK 29B 2RA 4.4 5B3 5GY 5VR 5VS 5ZH 6J9 7.M 7.Q 92L AAGCD AAJIO AAJKP AALHV AATNI ABHWH ABJNI ABQJV ACAFW ACGFS ACHIP AEFHF AENEX AFUIB AFYNE AHSEE AKPSB ALMA_UNASSIGNED_HOLDINGS ASPBG ATQHT AVWKF AZFZN BBWZM CCEZO CCVFK CEBXE CHBEP CJUJL CQIGP CRLBU CS3 DU5 EBS EDWGO EJD EMSAF EPQRW EQZZN FA0 FEDTE HAK HVGLF IJHAN IOP IZVLO JCGBZ KNG KOT M45 N5L NT- NT. PJBAE Q02 RIN RNS ROL RPA RW3 SY9 TCJ TGP UCJ W28 ~WA -SA -S~ AAYXX ACARI ADEQX AERVB AGQPQ AOAED ARNYC CAJEA CITATION Q-- U1G U5K |
ID | FETCH-LOGICAL-c280t-348ea7bbfbc60a7cba6db44f70dfc22ba82603c6c9b20c5eb5b52326430b086d3 |
ISSN | 1674-1056 |
IngestDate | Thu Apr 24 22:53:51 EDT 2025 Tue Jul 01 02:55:19 EDT 2025 Wed Feb 14 10:05:16 EST 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 2 |
Language | English |
License | http://iopscience.iop.org/info/page/text-and-data-mining http://iopscience.iop.org/page/copyright |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c280t-348ea7bbfbc60a7cba6db44f70dfc22ba82603c6c9b20c5eb5b52326430b086d3 |
Notes | The stability and reliability of an ion source and its beam availability are extremely significant for any accelerator,especially for those high current long term CW operation ones like ADS. Although the first high quality 306-hours continuous wave(CW) operating curve at 50 m A@35 ke V has been successfully obtained with a standard compact 2.45 GHz ECR ion source at Peking University(PKU), but the uncertainties that caused beam trips before are unacceptable during an accelerator real operation and should be eliminated. Meanwhile, no permission will be given when the beam power is upgraded from 50 m A@35 ke V to 50 m A@50 ke V. To improve the PKU CW proton source quality, several upgrades were done recently. After those improvements, a new long term CW proton beam experiment at 50 m A@50 ke V was carried out in June 2016. The total running time is 300.5 hours, including near 6 hours ion source preparation and 294 hours non-disturb continuous operation. Within the continuous 13 days operation, no beam-off happened, no spark was observed,no beam drop appeared, no interrupting action was needed, and only a few beam fluctuations caused by the air conditional failure occurred. Beam availability and reliability within the 294 hours is 100%. The root-mean-square(RMS) emittance of this 50 m A@50 ke V CW proton beam is about 0.186 π.mm.mrad. A careful inspection of the ion source was done after this long term operation and no obvious damage was found. The restart experimental results obtained after the ion source inspection prove the high repeatability of PKU PMECRIS. In addition, a 130-m A H+beam was obtained at 50 k V with duty factor of 10%(100 Hz/1 ms) with this source. Details will be presented in this paper. Shi-Xiang Peng1, Ai-Lin Zhang1,2, Hai-Tao Ren1, Yuan Xu1, Tao Zhang1, Jing-Feng Zhang1, Jia-Mei Wen1, Zhi-Yu Guo1, Jia-Er Chen1,2 (1.SKLNPT& IHIP, School of Physics, Peking University, Beijing 100871, China; 2. University of Chinese Academy of Sciences, Beijing 100049, China) 11-5639/O4 PKU PMECRIS 50mA@50keV CW proton beam 300-hours continuous operation no beam-off |
PageCount | 4 |
ParticipantIDs | crossref_primary_10_1088_1674_1056_26_2_025206 crossref_citationtrail_10_1088_1674_1056_26_2_025206 chongqing_primary_671255960 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2017-02-01 |
PublicationDateYYYYMMDD | 2017-02-01 |
PublicationDate_xml | – month: 02 year: 2017 text: 2017-02-01 day: 01 |
PublicationDecade | 2010 |
PublicationTitle | Chinese physics B |
PublicationTitleAlternate | Chinese Physics |
PublicationYear | 2017 |
References | 1 5 7 Gobin R (3) 2002 George P (2) 1990 Sherman J (4) 1996; 2 Peng S X (6) 2015; 24 |
References_xml | – ident: 1 doi: 10.1063/1.3266145 – volume: 24 issn: 1674-1056 year: 2015 ident: 6 publication-title: Chin. Phys. – start-page: 553 year: 1990 ident: 2 publication-title: Proceedings of the Linear Accelerator Conference – ident: 5 doi: 10.1063/1.4738635 – start-page: 1712 year: 2002 ident: 3 publication-title: Proceedings of EPAC – ident: 7 doi: 10.1063/1.4932399 – volume: 2 start-page: 867 year: 1996 ident: 4 publication-title: IEEE |
SSID | ssj0061023 |
Score | 2.1282916 |
Snippet | The stability and reliability of an ion source and its beam availability are extremely significant for any accelerator,especially for those high current long... |
SourceID | crossref chongqing |
SourceType | Enrichment Source Index Database Publisher |
StartPage | 345 |
SubjectTerms | ECR离子源 光束功率 北京大学 可用性 可靠性 操作过程 质子源 高强度 |
Title | New progress on beam availability and reliability of PKU high intensity CW proton ECR ion source |
URI | http://lib.cqvip.com/qk/85823A/201702/671255960.html |
Volume | 26 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3db9MwELdgCIkXxKcoA-QH3qqsrhs72eNUDZXvCrVa34LPdbZIXQpbywN_PXd2nAaGJoYUWa1VX6XcT-e7893PjL2GPB3KLLMJSIxN0pHWiVHDMkl1mRlA82gNBYofP-nJPH23UIvdcYHvLtnAgf35176S_9EqzqFeqUv2BpptheIEfkb94ogaxvGfdEzFib7AiswVqhGcOe-bH6ZaBfbtwK104VZV_E4Vb-_nfSIp9kwRtS_JGJ-QGCLYOB5_6RMgQk6_67nSRdvu0jWpkMvdbc1T12Scz6pkgWA7vZKLPqqSD9Wu4ywYuompkplZx9nF1m8G2wasTR4C9zbR1nQE06mzFI16oAmPtjV0wzcYkl1DqaRnGrhqwtHsUTYhSqOOFT94Coy46nfi7D82tLbM0B-w53lBwgoSVkh8iiDmNruDIPVH-28_T-PurYnKgoL0-P-x6yvPB-3cQOIzCGKIk-NsXZ9-R0-j49t0nJTZA3a_iS74UYDKQ3bL1Y_Y3WlQ2WP2FQHDI2D4uuYEGN4FDEfA8A5g-LrkCBhOgOEtYPj4hAfAcAQMR8DwAJgnbP7meDaeJM0VG4mVudgkozR3JgMowWphMgtGLyFNy0wsSyslGIw-xchqewhSWOVAgUIfHN1YARgML0dP2V69rt0zxg8NlEIJmYEiEjUFthROlvjzpVMmhx7bb19U8S1QqRQ6G1JMq0WPpfHVFbZhp6dLUlbFtUrssYN2WZR57YLnN12wz-7t0P6C7W0utu4l-qEbeOWB8wsXnX3B |
linkProvider | IOP Publishing |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=New+progress+on+beam+availability+and+reliability+of+PKU+high+intensity+CW+proton+ECR+ion+source&rft.jtitle=Chinese+physics+B&rft.au=Peng%2C+Shi-Xiang&rft.au=Zhang%2C+Ai-Lin&rft.au=Ren%2C+Hai-Tao&rft.au=Xu%2C+Yuan&rft.date=2017-02-01&rft.issn=1674-1056&rft.volume=26&rft.issue=2&rft.spage=25206&rft_id=info:doi/10.1088%2F1674-1056%2F26%2F2%2F025206&rft.externalDBID=n%2Fa&rft.externalDocID=10_1088_1674_1056_26_2_025206 |
thumbnail_s | http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=http%3A%2F%2Fimage.cqvip.com%2Fvip1000%2Fqk%2F85823A%2F85823A.jpg |