Calibration parameters for the probing tip of a magnetic force microscope in the field of a test current loop
The subject of discussion is calibration of the tip of a magnetic force microscope using the field of a ring-shaped current loop. To calculate the calibration parameters, the magnetic contribution from the extended tip of the probe in the field of the current loop to the rigidity of the cantilever i...
Saved in:
Published in | Technical physics Vol. 51; no. 9; pp. 1223 - 1228 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
New York
Springer Nature B.V
01.09.2006
|
Subjects | |
Online Access | Get full text |
ISSN | 1063-7842 1090-6525 |
DOI | 10.1134/S1063784206090192 |
Cover
Abstract | The subject of discussion is calibration of the tip of a magnetic force microscope using the field of a ring-shaped current loop. To calculate the calibration parameters, the magnetic contribution from the extended tip of the probe in the field of the current loop to the rigidity of the cantilever is approximated by the contribution from a point magnetic dipole and magnetic “charge” in terms of the theoretical model adopted. Three simplified models of the conic tip (with a sharpened, blunted, and rounded top) are considered. The calculated dependences of the effective calibration parameters on the radius of the current loop are compared with experimental data. It is found that the model of a uniformly magnetized tip in the form of a blunted cone provides the best fit to the experiment. The calculation results may be helpful in simulating images obtained with a magnetic force microscope and numerically testing magnetic objects. |
---|---|
AbstractList | The subject of discussion is calibration of the tip of a magnetic force microscope using the field of a ring-shaped current loop. To calculate the calibration parameters, the magnetic contribution from the extended tip of the probe in the field of the current loop to the rigidity of the cantilever is approximated by the contribution from a point magnetic dipole and magnetic “charge” in terms of the theoretical model adopted. Three simplified models of the conic tip (with a sharpened, blunted, and rounded top) are considered. The calculated dependences of the effective calibration parameters on the radius of the current loop are compared with experimental data. It is found that the model of a uniformly magnetized tip in the form of a blunted cone provides the best fit to the experiment. The calculation results may be helpful in simulating images obtained with a magnetic force microscope and numerically testing magnetic objects. |
Author | Popkov, A. F. Goryachev, A. V. |
Author_xml | – sequence: 1 givenname: A. V. surname: Goryachev fullname: Goryachev, A. V. – sequence: 2 givenname: A. F. surname: Popkov fullname: Popkov, A. F. |
BookMark | eNp9kE9PwzAMxSM0JMbgA3CLxLkQp22aHtHEP2kSB-BcuWkyMrVJSbID35524wQSJ1vy79nP75wsnHeakCtgNwB5cfsKTOSVLDgTrGZQ8xOyhKnLRMnLxdyLPJvnZ-Q8xh1jALIUSzKssbdtwGS9oyMGHHTSIVLjA00fmo7Bt9ZtabIj9YYiHXDrdLJqJpSmg1XBR-VHTa07KIzVfXdkk46Jqn0I2iXaez9ekFODfdSXP3VF3h_u39ZP2ebl8Xl9t8kUr_KUYYkIbdvVUnDJVSs0ViqHmpUajYBS6hxVZ4pCSlnXjEkukEnZgeo6XoDJV-T6uHey_7mfXDQ7vw9uOtlwIYpCVCXUE1UdqfmFGLRplE2HJFJA2zfAmjnb5k-2kxJ-KcdgBwxf_2i-AcfBfWQ |
CitedBy_id | crossref_primary_10_1080_10589759_2023_2274007 crossref_primary_10_1088_1367_2630_14_4_043044 |
Cites_doi | 10.1109/20.617821 10.1109/20.334123 10.1063/1.361584 10.1109/20.800564 10.1109/20.706782 10.1063/1.118808 10.1007/978-3-642-97363-5_5 10.1016/S0304-8853(01)00529-7 10.1109/20.539319 10.1109/20.334130 10.1063/1.346713 10.1063/1.117712 10.1109/20.539318 10.1063/1.117813 |
ContentType | Journal Article |
Copyright | Pleiades Publishing, Inc. 2006. |
Copyright_xml | – notice: Pleiades Publishing, Inc. 2006. |
DBID | AAYXX CITATION |
DOI | 10.1134/S1063784206090192 |
DatabaseName | CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Physics |
EISSN | 1090-6525 |
EndPage | 1228 |
ExternalDocumentID | 10_1134_S1063784206090192 |
GroupedDBID | -Y2 -~X .VR 06D 0R~ 0VY 123 1N0 29Q 29~ 2J2 2JN 2JY 2KG 2KM 2LR 2VQ 2~H 30V 4.4 408 40D 40E 5VS 6NX 8TC 8UJ 95- 95. 95~ 96X AAAVM AABHQ AACDK AAHNG AAIAL AAJBT AAJKR AANZL AAPKM AARHV AARTL AASML AATNV AATVU AAUYE AAWCG AAYIU AAYQN AAYTO AAYXX AAYZH ABAKF ABBBX ABDBE ABDBF ABDZT ABECU ABFSG ABFTD ABFTV ABHLI ABHQN ABJNI ABJOX ABKCH ABKTR ABMNI ABMQK ABNWP ABQBU ABQSL ABSXP ABTEG ABTHY ABTKH ABTMW ABULA ABWNU ABXPI ACAOD ACBXY ACDTI ACGFS ACHSB ACHXU ACKNC ACMDZ ACMLO ACNCT ACOKC ACOMO ACPIV ACSTC ACUHS ACZOJ ADHHG ADHIR ADHKG ADKNI ADKPE ADMLS ADRFC ADTPH ADURQ ADYFF ADZKW AEBTG AEFQL AEGAL AEGNC AEJHL AEJRE AEKMD AEMSY AENEX AEOHA AEPYU AETLH AEVLU AEXYK AEZWR AFBBN AFDZB AFGCZ AFHIU AFLOW AFOHR AFQWF AFWTZ AFZKB AGAYW AGDGC AGJBK AGMZJ AGQMX AGQPQ AGRTI AGWIL AGWZB AGYKE AHAVH AHBYD AHPBZ AHSBF AHWEU AHYZX AIAKS AIGIU AIIXL AILAN AITGF AIXLP AJBLW AJRNO ALMA_UNASSIGNED_HOLDINGS ALWAN AMKLP AMXSW AMYLF AMYQR AOCGG ARMRJ ASPBG ATHPR AVWKF AXYYD AZFZN B-. B0M BA0 BDATZ BGNMA BSONS CAG CITATION COF CS3 CSCUP DDRTE DNIVK DPUIP DU5 EAD EAP EAS EBLON EBS EIOEI EJD EMK EPL ESBYG EST ESX FEDTE FERAY FFXSO FIGPU FINBP FNLPD FRRFC FSGXE FWDCC GGCAI GGRSB GJIRD GNWQR GQ7 H13 HF~ HG6 HMJXF HRMNR HVGLF HZ~ I-F IAO IGS IJ- IKXTQ IWAJR IXD I~X I~Z J-C JBSCW JZLTJ KOV LLZTM M4Y MA- N2Q NB0 NPVJJ NQJWS NU0 O9- O93 O9J P9T PF0 PT4 QOS R89 R9I RIG RNS ROL RSV S16 S1Z S27 S3B SAP SDH SHX SISQX SJYHP SNE SNPRN SNX SOHCF SOJ SPH SPISZ SRMVM SSLCW STPWE SZN T13 TSG TUC TUS UG4 UOJIU UTJUX UZXMN VC2 VCL VFIZW VIT VOH W23 W48 WK8 YLTOR ZMTXR ~8M ~A9 ABRTQ |
ID | FETCH-LOGICAL-c273t-a5aa1bbd986282cb6ea7c31905eaf6158e3acdf448889900826a088d1cdd241f3 |
ISSN | 1063-7842 |
IngestDate | Tue Sep 16 14:31:52 EDT 2025 Thu Apr 24 23:11:21 EDT 2025 Tue Jul 01 04:14:03 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 9 |
Language | English |
License | https://www.springer.com/tdm |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c273t-a5aa1bbd986282cb6ea7c31905eaf6158e3acdf448889900826a088d1cdd241f3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 |
PQID | 2664467519 |
PQPubID | 2043675 |
PageCount | 6 |
ParticipantIDs | proquest_journals_2664467519 crossref_citationtrail_10_1134_S1063784206090192 crossref_primary_10_1134_S1063784206090192 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2006-09-01 |
PublicationDateYYYYMMDD | 2006-09-01 |
PublicationDate_xml | – month: 09 year: 2006 text: 2006-09-01 day: 01 |
PublicationDecade | 2000 |
PublicationPlace | New York |
PublicationPlace_xml | – name: New York |
PublicationTitle | Technical physics |
PublicationYear | 2006 |
Publisher | Springer Nature B.V |
Publisher_xml | – name: Springer Nature B.V |
References | P. Rice (9019_CR12) 1996; 32 R. Proksch (9019_CR9) 1996; 69 M. A. Al-Khafaji (9019_CR13) 1996; 32 J. C. Wu (9019_CR6) 1999; 35 P. Grutter (9019_CR2) 1992 K. Babcock (9019_CR11) 1994; 30 X. Song (9019_CR3) 1996; 79 S. S. Malhotra (9019_CR4) 1997; 33 A. M. Alexeev (9019_CR5) 2003; 258–259 K. Linshi (9019_CR15) 1997; 70 L. Wilkens (9019_CR8) 2002; 40 R. Proksh (9019_CR7) 1994; 30 K. L. Babcock (9019_CR14) 1996; 69 S. K. Khizroev (9019_CR10) 1998; 34 D. Rugar (9019_CR1) 1990; 68 E. F. Wassermann (9019_CR16) 2002; 239 |
References_xml | – volume: 33 start-page: 2992 year: 1997 ident: 9019_CR4 publication-title: IEEE Trans. Magn. doi: 10.1109/20.617821 – volume: 30 start-page: 4467 year: 1994 ident: 9019_CR7 publication-title: IEEE Trans. Magn. doi: 10.1109/20.334123 – volume: 79 start-page: 4912 year: 1996 ident: 9019_CR3 publication-title: J. Appl. Phys. doi: 10.1063/1.361584 – volume: 35 start-page: 3481 year: 1999 ident: 9019_CR6 publication-title: IEEE Trans. Magn. doi: 10.1109/20.800564 – volume: 34 start-page: 2030 year: 1998 ident: 9019_CR10 publication-title: IEEE Trans. Magn. doi: 10.1109/20.706782 – volume: 70 start-page: 2043 year: 1997 ident: 9019_CR15 publication-title: Appl. Phys. Lett. doi: 10.1063/1.118808 – start-page: 151 volume-title: Scanning Tunneling Microscopy II year: 1992 ident: 9019_CR2 doi: 10.1007/978-3-642-97363-5_5 – volume: 239 start-page: 220 year: 2002 ident: 9019_CR16 publication-title: J. Magn. Magn. Mater. doi: 10.1016/S0304-8853(01)00529-7 – volume: 40 start-page: 2065 year: 2002 ident: 9019_CR8 publication-title: J. Appl. Phys. – volume: 32 start-page: 4138 year: 1996 ident: 9019_CR13 publication-title: IEEE Trans. Magn. doi: 10.1109/20.539319 – volume: 30 start-page: 4503 year: 1994 ident: 9019_CR11 publication-title: IEEE Trans. Magn. doi: 10.1109/20.334130 – volume: 68 start-page: 1169 year: 1990 ident: 9019_CR1 publication-title: J. Appl. Phys. doi: 10.1063/1.346713 – volume: 258–259 start-page: 29 year: 2003 ident: 9019_CR5 publication-title: J. Magn. Magn. Mater. – volume: 69 start-page: 2599 year: 1996 ident: 9019_CR9 publication-title: Appl. Phys. Lett. doi: 10.1063/1.117712 – volume: 32 start-page: 4133 year: 1996 ident: 9019_CR12 publication-title: IEEE Trans. Magn. doi: 10.1109/20.539318 – volume: 69 start-page: 705 year: 1996 ident: 9019_CR14 publication-title: Appl. Phys. Lett. doi: 10.1063/1.117813 |
SSID | ssj0011856 |
Score | 1.6817824 |
Snippet | The subject of discussion is calibration of the tip of a magnetic force microscope using the field of a ring-shaped current loop. To calculate the calibration... |
SourceID | proquest crossref |
SourceType | Aggregation Database Enrichment Source Index Database |
StartPage | 1223 |
SubjectTerms | Calibration Magnetic dipoles Magnetic force microscopy Mathematical models Parameters |
Title | Calibration parameters for the probing tip of a magnetic force microscope in the field of a test current loop |
URI | https://www.proquest.com/docview/2664467519 |
Volume | 51 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LT9wwELYKCIlL1ReCFpAPPRUlJHHiJEcoLKhSqx6g4hY5toMQbLKCtFL59cz4kSyPIugl2rWcsXbn8_gbe2ZMyOdclYo1TRJwGesglTwNai55IDmLVB5JyWJMFP7-gx-dpN9Os9MxrMhkl_R1KG8ezSv5H61CG-gVs2RfoNlBKDTAZ9AvPEHD8HyWjjGxqnYqxBreU4xtuR4iB_GyGJMNdT6zaZBTcdZi0iL2gPk8xWA8k5biox1NPJvtCxS035auetNl183maazZkDfqtTsjAzE_7K7-YonoP8bmhNu_wsH2drOLzjdPwvu7DaXfbbAGEihNkBe2IlaoXVsJLmhmE5i9Vc3iOfSUcyYyTmyCsVtu4WvxuClnKR4m44A4XsRhlLhMxnXLn9XfW86GIEPj3rC0eiBigSwleY6H-ku7e_t7k-HUCbiLyUbzv9GdgoOQnQdC7vKYu8u44SbHb8hr51TQXYuQt-SVbt-R5Z9WNe_JdA4ndMQJBRRQ0Dp1OKGAE9o1VFCPE2pwQkec0PPWvGFwYvsiTqjDCUWcfCAnk4Pjr0eBu2YjkMBd-0BkQsR1rUpwbotE1lyLHKZoGWVaNEB4C82EVA348QU458gZuYC1ScVSKeB_DVsli23X6jVCWdZERRnJNJbQP1MiKyRrRBEJDWIEXyeR_9Mq6WrQ41Uol9U_lbVOvgyvzGwBlqc6b3hNVG6eXldAQVOgA-CqfHyJrE9kZZwAG2Sxv_qtN4GA9vWWw80tOB5_MQ |
linkProvider | EBSCOhost |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Calibration+parameters+for+the+probing+tip+of+a+magnetic+force+microscope+in+the+field+of+a+test+current+loop&rft.jtitle=Technical+physics&rft.au=Goryachev%2C+A.+V.&rft.au=Popkov%2C+A.+F.&rft.date=2006-09-01&rft.issn=1063-7842&rft.eissn=1090-6525&rft.volume=51&rft.issue=9&rft.spage=1223&rft.epage=1228&rft_id=info:doi/10.1134%2FS1063784206090192&rft.externalDBID=n%2Fa&rft.externalDocID=10_1134_S1063784206090192 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1063-7842&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1063-7842&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1063-7842&client=summon |