Theoretical Study of Dual-Function Sensor for Analysis of Blood Composition and Glucose Concentration Based on Nonreciprocal Analog of the Electromagnetically Induced Absorption
A nonreciprocal biosensor for the detection of different liquid substances is proposed based on an analog of the electromagnetically induced absorption (EIA-like) effect. Different bright-mode and dark-mode coupling structures are designed for the forward and backward incidences, respectively, and a...
Saved in:
Published in | IEEE transactions on instrumentation and measurement Vol. 72; pp. 1 - 10 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
New York
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
2023
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | A nonreciprocal biosensor for the detection of different liquid substances is proposed based on an analog of the electromagnetically induced absorption (EIA-like) effect. Different bright-mode and dark-mode coupling structures are designed for the forward and backward incidences, respectively, and as a result, the incisive EIA-like peaks are staggered at different frequency points. The regulation of nonreciprocal EIA-like effects by the shifts of metal thickness and incident angle is discussed. The EIA-like peaks in different directions occupy different measurement ranges (MRs) and detection capabilities, so they are suitable for detecting blood components and glucose concentrations, accordingly. Multiple layers of analyte cavities are introduced to increase the sensitivity ([Formula Omitted]) of the sensor. For the forward incidence, the [Formula Omitted] of the measurement after fitting the response frequency points under different blood components is 190.85 THz/RIU, the figure of merit (FOM) is 367.02, and the detection limit (DL) is [Formula Omitted]. For the detection of glucose solution concentration of 0–350 g/L at the backward incidence, the corresponding indicators are 337.46 THz/RIU, 1297, and [Formula Omitted] (0.32 g/L). The interferences of the thickness error of the analyte cavity on the sensor are also explored. |
---|---|
AbstractList | A nonreciprocal biosensor for the detection of different liquid substances is proposed based on an analog of the electromagnetically induced absorption (EIA-like) effect. Different bright-mode and dark-mode coupling structures are designed for the forward and backward incidences, respectively, and as a result, the incisive EIA-like peaks are staggered at different frequency points. The regulation of nonreciprocal EIA-like effects by the shifts of metal thickness and incident angle is discussed. The EIA-like peaks in different directions occupy different measurement ranges (MRs) and detection capabilities, so they are suitable for detecting blood components and glucose concentrations, accordingly. Multiple layers of analyte cavities are introduced to increase the sensitivity ([Formula Omitted]) of the sensor. For the forward incidence, the [Formula Omitted] of the measurement after fitting the response frequency points under different blood components is 190.85 THz/RIU, the figure of merit (FOM) is 367.02, and the detection limit (DL) is [Formula Omitted]. For the detection of glucose solution concentration of 0–350 g/L at the backward incidence, the corresponding indicators are 337.46 THz/RIU, 1297, and [Formula Omitted] (0.32 g/L). The interferences of the thickness error of the analyte cavity on the sensor are also explored. |
Author | Wan, Bao-Fei Li, Bing-Xiang Zhang, Hai-Feng |
Author_xml | – sequence: 1 givenname: Bao-Fei orcidid: 0000-0003-0361-4799 surname: Wan fullname: Wan, Bao-Fei organization: College of Electronic and Optical Engineering and the College of Flexible Electronics (Future Technology), Nanjing University of Posts and Telecommunications, Nanjing, China – sequence: 2 givenname: Bing-Xiang orcidid: 0000-0003-4727-1572 surname: Li fullname: Li, Bing-Xiang organization: College of Electronic and Optical Engineering and the College of Flexible Electronics (Future Technology), Nanjing University of Posts and Telecommunications, Nanjing, China – sequence: 3 givenname: Hai-Feng orcidid: 0000-0002-9890-8345 surname: Zhang fullname: Zhang, Hai-Feng organization: College of Electronic and Optical Engineering and the College of Flexible Electronics (Future Technology), Nanjing University of Posts and Telecommunications, Nanjing, China |
BookMark | eNp1UctuIyEQRKtEWudxzxFpz-NtZszAHB1vHpbyONg5jzD0OBNh8AJz8GflD5exc1opB0Srqaouui7ImfMOCblhMGUMmt_r5fO0hLKaVlXJJW9-kAnjXBRNXZdnZALAZNHMeP2TXMT4AQCinokJ-Vy_ow-Yeq0sXaXBHKjv6J9B2eJ-cDr13tEVuugD7fKZO2UPsY8j6NZ6b-jC7_Y-9kegcoY-2EH7iLnvNLoU1PHlVkU0NBcv3gXU_T74ceAo57ejWHpHemdRp-B3autOhuyBLp0ZdKbON9nCftS6IuedshGvv-5L8nZ_t148Fk-vD8vF_KnQpWCpqDYbZgRHZGAEA5V_m_sIwCsA3fFKlhtuFBiGyA3oms9ErUQumwqaTlWX5NdJN3v9O2BM7YcfQjYc21LKmRRCSplRcELp4GMM2LX70O9UOLQM2jGYNgfTjsG0X8FkSv0fRffpuKa8rd5-T_wHeNGXUQ |
CitedBy_id | crossref_primary_10_1103_PhysRevApplied_21_034060 crossref_primary_10_1063_5_0212260 crossref_primary_10_3390_ma17143534 |
Cites_doi | 10.1109/LPT.2016.2554123 10.1016/j.snb.2019.02.013 10.1109/JSTQE.2018.2873481 10.1016/j.snb.2017.08.031 10.1016/j.optcom.2017.12.037 10.1109/JSEN.2019.2895166 10.1109/ICUFN.2017.7993816 10.1364/OL.30.000699 10.1016/j.optlastec.2020.106332 10.1109/JSEN.2021.3070731 10.1109/JSEN.2020.2964715 10.1016/j.rinp.2020.103151 10.1364/AO.56.008372 10.3390/s8042453 10.1364/OE.24.016016 10.1021/nl2039748 10.1103/PhysRevA.59.4732 10.1088/1555-6611/ab5797 10.1109/JSEN.2021.3103548 10.1103/PhysRevX.7.021048 10.1038/s41598-020-66427-6 10.1002/lpor.201500045 10.1007/s12596-020-00600-y 10.1002/9781118354162 10.1007/s11082-021-03012-9 10.1364/OE.24.026201 10.1103/PhysRevLett.58.2059 10.1016/j.physleta.2015.05.011 |
ContentType | Journal Article |
Copyright | Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2023 |
Copyright_xml | – notice: Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2023 |
DBID | AAYXX CITATION 7SP 7U5 8FD L7M |
DOI | 10.1109/TIM.2023.3325859 |
DatabaseName | CrossRef Electronics & Communications Abstracts Solid State and Superconductivity Abstracts Technology Research Database Advanced Technologies Database with Aerospace |
DatabaseTitle | CrossRef Solid State and Superconductivity Abstracts Technology Research Database Advanced Technologies Database with Aerospace Electronics & Communications Abstracts |
DatabaseTitleList | Solid State and Superconductivity Abstracts |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering Physics |
EISSN | 1557-9662 |
EndPage | 10 |
ExternalDocumentID | 10_1109_TIM_2023_3325859 |
GroupedDBID | -~X 0R~ 29I 4.4 5GY 5VS 6IK 85S 8WZ 97E A6W AAJGR AARMG AASAJ AAWTH AAYOK AAYXX ABAZT ABQJQ ABVLG ACGFO ACIWK ACNCT AENEX AETIX AGQYO AGSQL AHBIQ AI. AIBXA AKJIK AKQYR ALLEH ALMA_UNASSIGNED_HOLDINGS ATWAV BEFXN BFFAM BGNUA BKEBE BPEOZ CITATION CS3 DU5 EBS EJD F5P HZ~ H~9 IAAWW IBMZZ ICLAB IDIHD IFIPE IFJZH IPLJI JAVBF LAI M43 O9- OCL P2P RIA RIE RIG RNS TN5 TWZ VH1 VJK 7SP 7U5 8FD L7M |
ID | FETCH-LOGICAL-c271t-3bb1d75ee10d710a647271e005300cf5382b5da0d1ee5d0c65476a75d09309fa3 |
ISSN | 0018-9456 |
IngestDate | Mon Jun 30 10:26:35 EDT 2025 Thu Apr 24 23:02:24 EDT 2025 Tue Jul 01 03:07:33 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Language | English |
License | https://ieeexplore.ieee.org/Xplorehelp/downloads/license-information/IEEE.html https://doi.org/10.15223/policy-029 https://doi.org/10.15223/policy-037 |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c271t-3bb1d75ee10d710a647271e005300cf5382b5da0d1ee5d0c65476a75d09309fa3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 |
ORCID | 0000-0003-4727-1572 0000-0003-0361-4799 0000-0002-9890-8345 |
PQID | 2884877888 |
PQPubID | 85462 |
PageCount | 10 |
ParticipantIDs | proquest_journals_2884877888 crossref_primary_10_1109_TIM_2023_3325859 crossref_citationtrail_10_1109_TIM_2023_3325859 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2023-00-00 20230101 |
PublicationDateYYYYMMDD | 2023-01-01 |
PublicationDate_xml | – year: 2023 text: 2023-00-00 |
PublicationDecade | 2020 |
PublicationPlace | New York |
PublicationPlace_xml | – name: New York |
PublicationTitle | IEEE transactions on instrumentation and measurement |
PublicationYear | 2023 |
Publisher | The Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
Publisher_xml | – name: The Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
References | ref13 ref12 ref15 ref14 ref11 ref10 ref2 ref1 ref17 ref16 ref19 ref18 ref24 ref23 ref26 ref25 ref20 ref22 ref21 ref28 Harris (ref3) 2011 ref27 ref29 ref8 ref7 ref9 ref4 ref6 ref5 |
References_xml | – ident: ref18 doi: 10.1109/LPT.2016.2554123 – ident: ref13 doi: 10.1016/j.snb.2019.02.013 – ident: ref9 doi: 10.1109/JSTQE.2018.2873481 – ident: ref14 doi: 10.1016/j.snb.2017.08.031 – ident: ref21 doi: 10.1016/j.optcom.2017.12.037 – ident: ref8 doi: 10.1109/JSEN.2019.2895166 – ident: ref7 doi: 10.1109/ICUFN.2017.7993816 – ident: ref23 doi: 10.1364/OL.30.000699 – ident: ref6 doi: 10.1016/j.optlastec.2020.106332 – ident: ref16 doi: 10.1109/JSEN.2021.3070731 – ident: ref25 doi: 10.1109/JSEN.2020.2964715 – ident: ref11 doi: 10.1016/j.rinp.2020.103151 – ident: ref20 doi: 10.1364/AO.56.008372 – ident: ref5 doi: 10.3390/s8042453 – ident: ref10 doi: 10.1364/OE.24.016016 – ident: ref17 doi: 10.1021/nl2039748 – ident: ref19 doi: 10.1103/PhysRevA.59.4732 – ident: ref26 doi: 10.1088/1555-6611/ab5797 – ident: ref28 doi: 10.1109/JSEN.2021.3103548 – ident: ref24 doi: 10.1103/PhysRevX.7.021048 – ident: ref27 doi: 10.1038/s41598-020-66427-6 – ident: ref2 doi: 10.1002/lpor.201500045 – ident: ref12 doi: 10.1007/s12596-020-00600-y – volume-title: A compact optical sensor for parallel analysis of blood components year: 2011 ident: ref3 – ident: ref1 doi: 10.1002/9781118354162 – ident: ref15 doi: 10.1007/s11082-021-03012-9 – ident: ref22 doi: 10.1364/OE.24.026201 – ident: ref4 doi: 10.1103/PhysRevLett.58.2059 – ident: ref29 doi: 10.1016/j.physleta.2015.05.011 |
SSID | ssj0007647 |
Score | 2.3976762 |
Snippet | A nonreciprocal biosensor for the detection of different liquid substances is proposed based on an analog of the electromagnetically induced absorption... |
SourceID | proquest crossref |
SourceType | Aggregation Database Enrichment Source Index Database |
StartPage | 1 |
SubjectTerms | Absorption Biosensors Blood Coupled modes Error analysis Figure of merit Glucose Holes Sensors Thickness |
Title | Theoretical Study of Dual-Function Sensor for Analysis of Blood Composition and Glucose Concentration Based on Nonreciprocal Analog of the Electromagnetically Induced Absorption |
URI | https://www.proquest.com/docview/2884877888 |
Volume | 72 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3NbtNAEF6FIiQ4VFBALS1oD1xQ5XT9bx-b0hCQ2guplJu1Xq-rSIldkfQAb8Wb9JE6szt27LYgysWyHWe90XyZmZ39Zoaxj4WIpK9T7aSJj6EbXTh5ApdY6rvEbaFIY4Lz2Xk0uQi-zcLZYHDTYS1dr_Oh-vVgXsn_SBXugVwxS_YRkm0HhRtwDvKFI0gYjv8q4zYL8XtTHfrztVw4YzBXpAuqVf3DkAm79UdGyFc3yoBIW2YT4Qvx108wl7GigrqHIzB0BW4qnNcV1sJAm4eCrTDu03AMTm07naW8rOyEFj8PsS0I0guOc5jCVYsAcoVxmYkdKpp25WbfYm4K2i4pIcrOarkJY27C_7bLvKydsZ63pCLDTBiBMXZmgPrLe0HxiZzD8_QBhTpsHnKjuF3Qy0FIVbNJV4cxFhftKXPbB4i0sdsx65Y8e99gmHqr069nQ3zh0Pc9WD-lG-PYEALu2MyWyWjWUCLNYIQMR8hohCfsqQcLF89mFLa-QRwFtoor_Zxm41ykR3fn0HeU-n6CcX6mL9k2rVr4sYXgKzbQ1Q570allucOeGS6xWr1mvzuw5AaWvC55D5bcwpIDLHkDS3zIwJJ3YMkBAJxgyXuw5AaWHE56sOQWljgYwJI_AEtOsOQbWL5hF-PT6cnEoc4gjvJid-34ee4Wcai1KwpwkSX2QIhdjRZFCFWCEffysJCicLUOC6Gww3YkYzhNfZGW0n_Ltqq60ruMh6XQBQhKJZ4KUmQN5ImvlCdDL5Jh4O6xo0YMmaKy-di9ZZH9SfR77FP7jStbMuYvzx40ks1IsawyL0mCJMbY1LtHDLXPnuOlDQ8esC34t-r34DCv8w8Gg7c4FsVS |
linkProvider | IEEE |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Theoretical+Study+of+Dual-Function+Sensor+for+Analysis+of+Blood+Composition+and+Glucose+Concentration+Based+on+Nonreciprocal+Analog+of+the+Electromagnetically+Induced+Absorption&rft.jtitle=IEEE+transactions+on+instrumentation+and+measurement&rft.au=Wan%2C+Bao-Fei&rft.au=Li%2C+Bing-Xiang&rft.au=Zhang%2C+Hai-Feng&rft.date=2023&rft.issn=0018-9456&rft.eissn=1557-9662&rft.volume=72&rft.spage=1&rft.epage=10&rft_id=info:doi/10.1109%2FTIM.2023.3325859&rft.externalDBID=n%2Fa&rft.externalDocID=10_1109_TIM_2023_3325859 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0018-9456&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0018-9456&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0018-9456&client=summon |