Evaluation of Pseudoisochromatic Plates for Grading
In order to evaluate the validity of grading plated, the results of the TMC Plates and Ishihara-Okuma Plates of 886 subjects, and those of the Ishihara tests of 1, 000 subjects were reviewed. Color vision defects of all the subjects were diagnosed with a battery of color vision tests including anoma...
Saved in:
Published in | JAPANESE ORTHOPTIC JOURNAL Vol. 25; pp. 233 - 237 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS
1997
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | In order to evaluate the validity of grading plated, the results of the TMC Plates and Ishihara-Okuma Plates of 886 subjects, and those of the Ishihara tests of 1, 000 subjects were reviewed. Color vision defects of all the subjects were diagnosed with a battery of color vision tests including anomaloscope. With the TMC Plates, 20.1% of dichromats scored moderate or mild degree and 33.4% of anomalous trichromats scored high degree. With the Ishihara-Okuma Plates, 53.8% of dichromats scored moderate or mild degree and 10.8% of anomalous trichromats scored high degree. In each subject, diagnoses of two plates were often different. With the Ishihara test, 85.9% of anomalous trichromats were judged to be dichromats. Thus, results of grading plates are rather inconsistent with real degrees of color vision defects. The reason of such inconsistency is well explained when the colors used in the plates are plotted on Fransworth's Uniform Chromaicity Scale Diagram. |
---|---|
AbstractList | In order to evaluate the validity of grading plated, the results of the TMC Plates and Ishihara-Okuma Plates of 886 subjects, and those of the Ishihara tests of 1, 000 subjects were reviewed. Color vision defects of all the subjects were diagnosed with a battery of color vision tests including anomaloscope. With the TMC Plates, 20.1% of dichromats scored moderate or mild degree and 33.4% of anomalous trichromats scored high degree. With the Ishihara-Okuma Plates, 53.8% of dichromats scored moderate or mild degree and 10.8% of anomalous trichromats scored high degree. In each subject, diagnoses of two plates were often different. With the Ishihara test, 85.9% of anomalous trichromats were judged to be dichromats. Thus, results of grading plates are rather inconsistent with real degrees of color vision defects. The reason of such inconsistency is well explained when the colors used in the plates are plotted on Fransworth's Uniform Chromaicity Scale Diagram. |
Author | Tanabe, Shoko Ishiguro, Susumu Hukami, Kaitiro Akiyama, Maki |
Author_xml | – sequence: 1 fullname: Ishiguro, Susumu organization: Japanese Red Cross Nagoya First Hospital – sequence: 2 fullname: Akiyama, Maki organization: Japanese Red Cross Nagoya First Hospital – sequence: 3 fullname: Tanabe, Shoko organization: Japanese Red Cross Nagoya First Hospital – sequence: 4 fullname: Hukami, Kaitiro organization: Japanese Red Cross Nagoya First Hospital |
BookMark | eNpNj8FKAzEQhoNUsNY-gLd9ga3JzGaTHKXUqhTsQc8hm03aLdtNSbaCb--WluocZuDn_wa-ezLqQucIeWR0VkCJT7sQ-2049I2dAZ8B4g0ZMykxV8D4iIwpSpFzJuCOTFPa0WFQKoZsTHDxbdqj6ZvQZcFn6-SOdWhSsNsY9kNss3VrepcyH2K2jKZuus0DufWmTW56uRPy9bL4nL_mq4_l2_x5lVvgAvMaqVfo0IGiVSWYUbYyZQkSKopgJXghXSU5K6z1Bi0vvIfKlVDXipVS4YSw818bQ0rReX2Izd7EH82oPonrP3ENXA_iA_N-ZnapNxt3JUwcSq37RzAlxImil4V4Ldmtidp1-AsF12uO |
CitedBy_id | crossref_primary_10_4263_jorthoptic_49F203 |
ContentType | Journal Article |
Copyright | JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS |
Copyright_xml | – notice: JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS |
DBID | AAYXX CITATION |
DOI | 10.4263/jorthoptic.25.233 |
DatabaseName | CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
EISSN | 1883-9215 |
EndPage | 237 |
ExternalDocumentID | 10_4263_jorthoptic_25_233 article_jorthoptic1977_25_0_25_0_233_article_char_en |
GroupedDBID | ALMA_UNASSIGNED_HOLDINGS JSF KQ8 RJT AAYXX CITATION |
ID | FETCH-LOGICAL-c2573-d30f93e3e290bb71a9cba66282b032c82f78eb8514ccfa3c54ff2be62dd916893 |
ISSN | 0387-5172 |
IngestDate | Fri Aug 23 04:01:59 EDT 2024 Wed Apr 05 15:04:18 EDT 2023 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | true |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c2573-d30f93e3e290bb71a9cba66282b032c82f78eb8514ccfa3c54ff2be62dd916893 |
OpenAccessLink | https://www.jstage.jst.go.jp/article/jorthoptic1977/25/0/25_0_233/_article/-char/en |
PageCount | 5 |
ParticipantIDs | crossref_primary_10_4263_jorthoptic_25_233 jstage_primary_article_jorthoptic1977_25_0_25_0_233_article_char_en |
PublicationCentury | 1900 |
PublicationDate | 1997 |
PublicationDateYYYYMMDD | 1997-01-01 |
PublicationDate_xml | – year: 1997 text: 1997 |
PublicationDecade | 1990 |
PublicationTitle | JAPANESE ORTHOPTIC JOURNAL |
PublicationTitleAlternate | Jpn. Orthopt. J. |
PublicationYear | 1997 |
Publisher | JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS |
Publisher_xml | – name: JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS |
References | 1) Farnsworth, D.: The F-M Test and Dichotomous Test for Color Vision. J. Opt. Soc. Amer. 33:568-578, 1943. 2) 天野みゆき, 鈴木永子, 河合美重子, 馬嶋昭生:色覚検査における各種程度判定方の比較. 日本視能訓練士協会誌, 20:182-189, 1992. 4) 馬嶋昭生:先天色覚異常の診断基準について(III)-パネルD-15とランタン併用による社会適性判断基準(馬嶋試案)とその検討-. 眼紀, 23:170-175, 1972. 3) 馬嶋昭生, 栗屋忍:色覚異常学童に於ける各種色覚検査法(Anomaloscope, 石原氏表, 大熊氏表, 東京医大式, H-R-R表及びLantern-Test)による成績の比較検討. 臨眼, 14:439-451, 1960. |
References_xml | |
SSID | ssj0000389131 ssib053390835 |
Score | 1.4073619 |
Snippet | In order to evaluate the validity of grading plated, the results of the TMC Plates and Ishihara-Okuma Plates of 886 subjects, and those of the Ishihara tests... |
SourceID | crossref jstage |
SourceType | Aggregation Database Publisher |
StartPage | 233 |
SubjectTerms | congenital color vision defect degree of color vision defect pseudoisochromatic plates |
Title | Evaluation of Pseudoisochromatic Plates for Grading |
URI | https://www.jstage.jst.go.jp/article/jorthoptic1977/25/0/25_0_233/_article/-char/en |
Volume | 25 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | JAPANESE ORTHOPTIC JOURNAL, 1997/07/20, Vol.25, pp.233-237 |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV3Nb9MwFLfK4MAFgQAxvpQDJ6YUx86He6y6lJbDWtZM2i2yHYdmZQ0qzYH9F_uP9xw7H2McYOJiVZGT2u89Pf_8_N7PCH0QGYB8CcabR4S6vmK5y32mXCI4DxSOuDRsnyfh7Mz_ch6cDwbXvaylai-G8uqPdSX30So8A73qKtl_0Gz7UXgAv0G_0IKGof0rHcctVXedyvZTVeChQNzrXWmYWJffNZSsUwk_73i7TDVgdLwcn8Sr-GhxmswWywQUYnOBOoNZF99sKcyqgqlVrYFsil_8kptyn03RBQC2XJio9rrclJ3RbPilyRvgxb7YlV2wQaeg9JYAO6KabXJurgRaTI8m8Wkyn87j43aoq2TV82GaujfwzO08Q2V8LGPUHRFTxdk4YRL0vajhxrALMjGsML_7es00r329Pt4qwb3KIQmG7Zu3KLStgtKurwewNyVBim1Dadp00tVuYFwP0EOiuQP1Of9X1obtcH2uW9_D2EzNnJXr4Xy6M5hbaOfRBQD-Jlmwxi_JU_TEbjycsfn_Z2igts8R7SzIKXPnrgU5xoIcsCDHWtALdDaNk8nMtddouBL8MXUzivMRVVSRERYi8vhICh6GsNcWmBLJSB4xJQB5-1LmnMrAz3MiVEiyDPYOgGdfooNtuVWvkCMUw8LHCksv9zMW8BBHinKP-zq7SvJD9LGZbvrDsKWksMvUsukJX8scZHOIJkYgbdf76On1f_nKG_TY8BLr2NpbdLDfVeodoM29eF_r_waxvIWY |
link.rule.ids | 315,783,787,4033,27937,27938,27939 |
linkProvider | Colorado Alliance of Research Libraries |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluation+of+Pseudoisochromatic+Plates+for+Grading&rft.jtitle=JAPANESE+ORTHOPTIC+JOURNAL&rft.au=Ishiguro%2C+Susumu&rft.au=Akiyama%2C+Maki&rft.au=Tanabe%2C+Shoko&rft.au=Hukami%2C+Kaitiro&rft.date=1997&rft.pub=JAPANESE+ASSOCIATION+OF+CERTIFIED+ORTHOPTISTS&rft.issn=0387-5172&rft.eissn=1883-9215&rft.volume=25&rft.spage=233&rft.epage=237&rft_id=info:doi/10.4263%2Fjorthoptic.25.233&rft.externalDocID=article_jorthoptic1977_25_0_25_0_233_article_char_en |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0387-5172&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0387-5172&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0387-5172&client=summon |