Assessment of 1H-MRS spectra via multiset canonical correlation analysis and empirical mode decomposition
Proton magnetic resonance spectroscopy (1H-MRS) is a valuable non-invasive method for quantifying brain metabolites. Most MRS spectra are pre-processed by taking the mean of several single-acquisition transients, ultimately resulting in peaks associated with biologically significant molecules. Howev...
Saved in:
Published in | Computers in biology and medicine Vol. 187; p. 109806 |
---|---|
Main Authors | , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Elsevier Ltd
01.03.2025
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Proton magnetic resonance spectroscopy (1H-MRS) is a valuable non-invasive method for quantifying brain metabolites. Most MRS spectra are pre-processed by taking the mean of several single-acquisition transients, ultimately resulting in peaks associated with biologically significant molecules. However, simply taking the mean of the transients is prone to errors due to outliers and the non-independence of sequential data acquisitions. Furthermore, this approach cannot identify whether peaks corresponding to different metabolites tend to co-vary across acquisitions. Averaging also assumes a single underlying true signal that is variably corrupted with noise.
In this study, we propose a novel analytic approach that models each transient as a combination of deterministic components. This method allows for the extraction of distinct orthogonal components of the MRS spectrum that variably contribute to each transient signal. First, complex Empirical Mode Decomposition (EMD) is applied to extract intrinsic mode functions from the free induction decay (FID) signals. Subsequently, Multiset Canonical Correlation Analysis (MCCA) is employed to obtain the linear combination of intrinsic mode functions from each FID signal that produce the most consistent temporal waveforms across all transients.
We applied this method to time-domain 1H-MRS data from 21 Alzheimer's disease (AD) subjects. Using the MCCA method, three significant orthogonal components were extracted. Regression analyses revealed that each of these components significantly contributed to the transient signals. To interpret the isolated spectra contained in the MCCA components, we utilized the LCModel program. The first component was qualitatively similar to the grand mean spectrum but demonstrated a dramatic 40.7 % increase in signal-to-noise ratio (SNR; p < 0.001). This component also exhibited lower Cramer-Rao Lower Bound (CRLB) values and statistically significant differences in the concentrations of key metabolites, including N-acetyl aspartate (NAA), myo-inositol (mI), and glutamate (Glu) (p < 0.05).
The second component contained similar peak values to the first, except for the NAA peak. A judicious combination of the first two components enabled selective variability in the NAA peak height across transients. The third component primarily extracted peaks related to total creatine (tCr) and total choline (tCho).
These findings indicate that 1H-MRS spectra consist of a combination of deterministic components. By isolating these components, the signal-to-noise ratio (SNR) of the spectra is enhanced, and the Cramer-Rao Lower Bound (CRLB) values for most metabolites are improved. This approach offers a novel framework for increasing the utility of 1H-MRS in both clinical and research applications.
[Display omitted]
•Novel 1H-MRS analysis improves metabolite detection in Alzheimer's patients.•MCCA approach increased signal-to-noise ratio by 40.7 % for MRS spectra.•Three orthogonal components revealed significant metabolite co-varying patterns.•Method enhances identification of key metabolites like NAA and Glu ratios.•Improved analysis techniques may advance neuroimaging and diagnostics research. |
---|---|
AbstractList | AbstractProton magnetic resonance spectroscopy ( 1H-MRS) is a valuable non-invasive method for quantifying brain metabolites. Most MRS spectra are pre-processed by taking the mean of several single-acquisition transients, ultimately resulting in peaks associated with biologically significant molecules. However, simply taking the mean of the transients is prone to errors due to outliers and the non-independence of sequential data acquisitions. Furthermore, this approach cannot identify whether peaks corresponding to different metabolites tend to co-vary across acquisitions. Averaging also assumes a single underlying true signal that is variably corrupted with noise. In this study, we propose a novel analytic approach that models each transient as a combination of deterministic components. This method allows for the extraction of distinct orthogonal components of the MRS spectrum that variably contribute to each transient signal. First, complex Empirical Mode Decomposition (EMD) is applied to extract intrinsic mode functions from the free induction decay (FID) signals. Subsequently, Multiset Canonical Correlation Analysis (MCCA) is employed to obtain the linear combination of intrinsic mode functions from each FID signal that produce the most consistent temporal waveforms across all transients. We applied this method to time-domain 1H-MRS data from 21 Alzheimer's disease (AD) subjects. Using the MCCA method, three significant orthogonal components were extracted. Regression analyses revealed that each of these components significantly contributed to the transient signals. To interpret the isolated spectra contained in the MCCA components, we utilized the LCModel program. The first component was qualitatively similar to the grand mean spectrum but demonstrated a dramatic 40.7 % increase in signal-to-noise ratio (SNR; p < 0.001). This component also exhibited lower Cramer-Rao Lower Bound (CRLB) values and statistically significant differences in the concentrations of key metabolites, including N-acetyl aspartate (NAA), myo-inositol (mI), and glutamate (Glu) (p < 0.05). The second component contained similar peak values to the first, except for the NAA peak. A judicious combination of the first two components enabled selective variability in the NAA peak height across transients. The third component primarily extracted peaks related to total creatine (tCr) and total choline (tCho). These findings indicate that 1H-MRS spectra consist of a combination of deterministic components. By isolating these components, the signal-to-noise ratio (SNR) of the spectra is enhanced, and the Cramer-Rao Lower Bound (CRLB) values for most metabolites are improved. This approach offers a novel framework for increasing the utility of 1H-MRS in both clinical and research applications. Proton magnetic resonance spectroscopy (1H-MRS) is a valuable non-invasive method for quantifying brain metabolites. Most MRS spectra are pre-processed by taking the mean of several single-acquisition transients, ultimately resulting in peaks associated with biologically significant molecules. However, simply taking the mean of the transients is prone to errors due to outliers and the non-independence of sequential data acquisitions. Furthermore, this approach cannot identify whether peaks corresponding to different metabolites tend to co-vary across acquisitions. Averaging also assumes a single underlying true signal that is variably corrupted with noise. In this study, we propose a novel analytic approach that models each transient as a combination of deterministic components. This method allows for the extraction of distinct orthogonal components of the MRS spectrum that variably contribute to each transient signal. First, complex Empirical Mode Decomposition (EMD) is applied to extract intrinsic mode functions from the free induction decay (FID) signals. Subsequently, Multiset Canonical Correlation Analysis (MCCA) is employed to obtain the linear combination of intrinsic mode functions from each FID signal that produce the most consistent temporal waveforms across all transients. We applied this method to time-domain 1H-MRS data from 21 Alzheimer's disease (AD) subjects. Using the MCCA method, three significant orthogonal components were extracted. Regression analyses revealed that each of these components significantly contributed to the transient signals. To interpret the isolated spectra contained in the MCCA components, we utilized the LCModel program. The first component was qualitatively similar to the grand mean spectrum but demonstrated a dramatic 40.7 % increase in signal-to-noise ratio (SNR; p < 0.001). This component also exhibited lower Cramer-Rao Lower Bound (CRLB) values and statistically significant differences in the concentrations of key metabolites, including N-acetyl aspartate (NAA), myo-inositol (mI), and glutamate (Glu) (p < 0.05). The second component contained similar peak values to the first, except for the NAA peak. A judicious combination of the first two components enabled selective variability in the NAA peak height across transients. The third component primarily extracted peaks related to total creatine (tCr) and total choline (tCho). These findings indicate that 1H-MRS spectra consist of a combination of deterministic components. By isolating these components, the signal-to-noise ratio (SNR) of the spectra is enhanced, and the Cramer-Rao Lower Bound (CRLB) values for most metabolites are improved. This approach offers a novel framework for increasing the utility of 1H-MRS in both clinical and research applications. [Display omitted] •Novel 1H-MRS analysis improves metabolite detection in Alzheimer's patients.•MCCA approach increased signal-to-noise ratio by 40.7 % for MRS spectra.•Three orthogonal components revealed significant metabolite co-varying patterns.•Method enhances identification of key metabolites like NAA and Glu ratios.•Improved analysis techniques may advance neuroimaging and diagnostics research. Proton magnetic resonance spectroscopy (1H-MRS) is a valuable non-invasive method for quantifying brain metabolites. Most MRS spectra are pre-processed by taking the mean of several single-acquisition transients, ultimately resulting in peaks associated with biologically significant molecules. However, simply taking the mean of the transients is prone to errors due to outliers and the non-independence of sequential data acquisitions. Furthermore, this approach cannot identify whether peaks corresponding to different metabolites tend to co-vary across acquisitions. Averaging also assumes a single underlying true signal that is variably corrupted with noise. In this study, we propose a novel analytic approach that models each transient as a combination of deterministic components. This method allows for the extraction of distinct orthogonal components of the MRS spectrum that variably contribute to each transient signal. First, complex Empirical Mode Decomposition (EMD) is applied to extract intrinsic mode functions from the free induction decay (FID) signals. Subsequently, Multiset Canonical Correlation Analysis (MCCA) is employed to obtain the linear combination of intrinsic mode functions from each FID signal that produce the most consistent temporal waveforms across all transients. We applied this method to time-domain 1H-MRS data from 21 Alzheimer's disease (AD) subjects. Using the MCCA method, three significant orthogonal components were extracted. Regression analyses revealed that each of these components significantly contributed to the transient signals. To interpret the isolated spectra contained in the MCCA components, we utilized the LCModel program. The first component was qualitatively similar to the grand mean spectrum but demonstrated a dramatic 40.7 % increase in signal-to-noise ratio (SNR; p < 0.001). This component also exhibited lower Cramer-Rao Lower Bound (CRLB) values and statistically significant differences in the concentrations of key metabolites, including N-acetyl aspartate (NAA), myo-inositol (mI), and glutamate (Glu) (p < 0.05). The second component contained similar peak values to the first, except for the NAA peak. A judicious combination of the first two components enabled selective variability in the NAA peak height across transients. The third component primarily extracted peaks related to total creatine (tCr) and total choline (tCho). These findings indicate that 1H-MRS spectra consist of a combination of deterministic components. By isolating these components, the signal-to-noise ratio (SNR) of the spectra is enhanced, and the Cramer-Rao Lower Bound (CRLB) values for most metabolites are improved. This approach offers a novel framework for increasing the utility of 1H-MRS in both clinical and research applications.Proton magnetic resonance spectroscopy (1H-MRS) is a valuable non-invasive method for quantifying brain metabolites. Most MRS spectra are pre-processed by taking the mean of several single-acquisition transients, ultimately resulting in peaks associated with biologically significant molecules. However, simply taking the mean of the transients is prone to errors due to outliers and the non-independence of sequential data acquisitions. Furthermore, this approach cannot identify whether peaks corresponding to different metabolites tend to co-vary across acquisitions. Averaging also assumes a single underlying true signal that is variably corrupted with noise. In this study, we propose a novel analytic approach that models each transient as a combination of deterministic components. This method allows for the extraction of distinct orthogonal components of the MRS spectrum that variably contribute to each transient signal. First, complex Empirical Mode Decomposition (EMD) is applied to extract intrinsic mode functions from the free induction decay (FID) signals. Subsequently, Multiset Canonical Correlation Analysis (MCCA) is employed to obtain the linear combination of intrinsic mode functions from each FID signal that produce the most consistent temporal waveforms across all transients. We applied this method to time-domain 1H-MRS data from 21 Alzheimer's disease (AD) subjects. Using the MCCA method, three significant orthogonal components were extracted. Regression analyses revealed that each of these components significantly contributed to the transient signals. To interpret the isolated spectra contained in the MCCA components, we utilized the LCModel program. The first component was qualitatively similar to the grand mean spectrum but demonstrated a dramatic 40.7 % increase in signal-to-noise ratio (SNR; p < 0.001). This component also exhibited lower Cramer-Rao Lower Bound (CRLB) values and statistically significant differences in the concentrations of key metabolites, including N-acetyl aspartate (NAA), myo-inositol (mI), and glutamate (Glu) (p < 0.05). The second component contained similar peak values to the first, except for the NAA peak. A judicious combination of the first two components enabled selective variability in the NAA peak height across transients. The third component primarily extracted peaks related to total creatine (tCr) and total choline (tCho). These findings indicate that 1H-MRS spectra consist of a combination of deterministic components. By isolating these components, the signal-to-noise ratio (SNR) of the spectra is enhanced, and the Cramer-Rao Lower Bound (CRLB) values for most metabolites are improved. This approach offers a novel framework for increasing the utility of 1H-MRS in both clinical and research applications. |
ArticleNumber | 109806 |
Author | Mirian, Maryam S. McKeown, Martin J. Ahdi, Alieh Vahabie, Abdol-Hossein Schulz, Bretta Russell Laule, Cornelia MacMillan, Erin Setaredan, Seyed Kamaledin Ensworth, Alex Nygaard, Haakon B. |
Author_xml | – sequence: 1 givenname: Alieh orcidid: 0000-0002-6177-5163 surname: Ahdi fullname: Ahdi, Alieh organization: School of Electrical and Computer Engineering, University of Tehran, Tehran, Iran – sequence: 2 givenname: Alex orcidid: 0000-0002-7101-3824 surname: Ensworth fullname: Ensworth, Alex organization: Physics & Astronomy, University of British Columbia, Vancouver, Canada – sequence: 3 givenname: Bretta Russell surname: Schulz fullname: Schulz, Bretta Russell organization: Physics & Astronomy, University of British Columbia, Vancouver, Canada – sequence: 4 givenname: Erin orcidid: 0000-0002-8515-5858 surname: MacMillan fullname: MacMillan, Erin organization: UBC MRI Research Centre, Faculty of Medicine, University of British Columbia, Vancouver, Canada – sequence: 5 givenname: Maryam S. surname: Mirian fullname: Mirian, Maryam S. organization: Pacific Parkinson's Research Centre, University of British Columbia, Vancouver, Canada – sequence: 6 givenname: Abdol-Hossein surname: Vahabie fullname: Vahabie, Abdol-Hossein organization: Cognitive Systems Laboratory, Control and Intelligent Processing Center of Excellence (CIPCE), School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran – sequence: 7 givenname: Cornelia surname: Laule fullname: Laule, Cornelia organization: International Collaboration on Repair Discoveries (ICORD), University of British Columbia, Vancouver, Canada – sequence: 8 givenname: Haakon B. surname: Nygaard fullname: Nygaard, Haakon B. organization: Division of Neurology, Department of Medicine, Faculty of Medicine, University of British Columbia, Vancouver, Canada – sequence: 9 givenname: Seyed Kamaledin surname: Setaredan fullname: Setaredan, Seyed Kamaledin organization: School of Electrical and Computer Engineering, University of Tehran, Tehran, Iran – sequence: 10 givenname: Martin J. orcidid: 0000-0002-4048-0817 surname: McKeown fullname: McKeown, Martin J. organization: Pacific Parkinson's Research Centre, University of British Columbia, Vancouver, Canada |
BookMark | eNqNkUFr3DAQhUVJoZu0_0HHXrwd2ZYtX0LT0HYDCYWmPQtJHoE2tuVqvIH995GzhUIhkJMG6c2bp2_O2dkUJ2SMC9gKEM2n_dbFcbYhjthvSyhlvu4UNG_YRqi2K0BW9RnbAAgoalXKd-ycaA8ANVSwYeGKCIlGnBYePRe74u7nPacZ3ZIMfwyGj4dhCYQLdyaPDs4M3MWUcDBLiBM3kxmOFCgXPcdxDulZMsYeeY9rtkhhVb5nb70ZCD_8PS_Y729ff13vitsf32-ur24LV8pKFjbn9UrWpfXYWOikr1Vr6jK_dr6yqmr6zktrZKNqbG3rvVcVil7UtrVobHXBPp585xT_HJAWPQZyOAxmwnggXYlGgoJWyCxVJ6lLkSih13MKo0lHLUCvdPVe_6OrV7r6RDe3fjm1Yv7KY8CkyQWcHPYhZXa6j-E1Jpf_mbghPCN-wCPSPh5SpktaaCo16Pt1iesOS5mrDCAbfH7Z4HUZngBRnraP |
Cites_doi | 10.1002/mrm.26619 10.21037/tp-20-445 10.3389/fnmol.2016.00014 10.1016/B978-0-323-91771-1.00012-5 10.1016/j.jmr.2020.106732 10.1002/mrm.28421 10.1002/1099-1492(200005)13:3<129::AID-NBM619>3.0.CO;2-V 10.1590/S0100-879X2012007500128 10.1097/WAD.0b013e3181611011 10.1002/mrm.22448 10.1002/hbm.25090 10.1098/rspa.1998.0193 10.1109/LSP.2006.882107 10.1002/mrm.1910300604 10.3389/fpsyt.2020.00769 10.1038/s41598-021-81193-9 10.1016/j.nic.2012.10.003 10.1016/j.jceh.2015.10.006 10.1016/j.nic.2012.10.002 10.1016/j.rcl.2021.01.004 10.1093/cercor/bhae046 10.1038/s41598-019-38981-1 10.1016/j.bbacli.2016.04.002 10.1016/j.jocs.2018.05.002 10.1007/s11481-013-9460-x 10.3389/fnene.2013.00011 10.1016/j.nicl.2019.101856 |
ContentType | Journal Article |
Copyright | 2025 Copyright © 2025. Published by Elsevier Ltd. |
Copyright_xml | – notice: 2025 – notice: Copyright © 2025. Published by Elsevier Ltd. |
DBID | AAYXX CITATION 7X8 |
DOI | 10.1016/j.compbiomed.2025.109806 |
DatabaseName | CrossRef MEDLINE - Academic |
DatabaseTitle | CrossRef MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1879-0534 |
EndPage | 109806 |
ExternalDocumentID | 10_1016_j_compbiomed_2025_109806 S0010482525001568 1_s2_0_S0010482525001568 |
GroupedDBID | --- --K --M --Z -~X .1- .55 .DC .FO .GJ .~1 0R~ 1B1 1P~ 1RT 1~. 1~5 29F 4.4 457 4G. 53G 5GY 5VS 7-5 71M 7RV 7X7 88E 8AO 8FE 8FG 8FH 8FI 8FJ 8G5 8P~ 9JN AAEDT AAEDW AAIKJ AAKOC AALRI AAOAW AAQFI AAQXK AATTM AAXKI AAXUO AAYFN AAYWO ABBOA ABFNM ABJNI ABMAC ABMZM ABOCM ABUWG ABWVN ABXDB ACDAQ ACGFS ACIEU ACIUM ACIWK ACNNM ACPRK ACRLP ACRPL ACVFH ACZNC ADBBV ADCNI ADEZE ADJOM ADMUD ADNMO AEBSH AEIPS AEKER AENEX AEUPX AEVXI AFJKZ AFKRA AFPUW AFRAH AFRHN AFTJW AFXIZ AGCQF AGHFR AGQPQ AGUBO AGYEJ AHHHB AHMBA AHZHX AIALX AIEXJ AIGII AIIUN AIKHN AITUG AJRQY AJUYK AKBMS AKRWK AKYEP ALMA_UNASSIGNED_HOLDINGS AMRAJ ANKPU ANZVX AOUOD APXCP ARAPS ASPBG AVWKF AXJTR AZFZN AZQEC BBNVY BENPR BGLVJ BHPHI BKEYQ BKOJK BLXMC BNPGV BPHCQ BVXVI CCPQU CS3 DU5 DWQXO EBS EFJIC EFKBS EJD EMOBN EO8 EO9 EP2 EP3 EX3 F5P FDB FEDTE FGOYB FIRID FNPLU FYGXN FYUFA G-2 G-Q GBLVA GBOLZ GNUQQ GUQSH HCIFZ HLZ HMCUK HMK HMO HVGLF HZ~ IHE J1W K6V K7- KOM LK8 LX9 M1P M29 M2O M41 M7P MO0 N9A NAPCQ O-L O9- OAUVE OZT P-8 P-9 P2P P62 PC. PHGZM PHGZT PJZUB PPXIY PQGLB PQQKQ PROAC PSQYO PUEGO Q38 R2- ROL RPZ RXW SAE SBC SCC SDF SDG SDP SEL SES SEW SPC SPCBC SSH SSV SSZ SV3 T5K TAE UAP UKHRP WOW WUQ X7M XPP Z5R ZGI ~G- AFCTW AGRNS ALIPV RIG AAYXX CITATION 7X8 |
ID | FETCH-LOGICAL-c2535-b534f8542bfe6b095f487a42c259f3b836d9f5ba5684e7b7fff83e1d14b7beab3 |
IEDL.DBID | .~1 |
ISSN | 0010-4825 1879-0534 |
IngestDate | Thu Jul 10 19:57:02 EDT 2025 Tue Jul 01 05:02:55 EDT 2025 Sat May 24 17:05:38 EDT 2025 Fri May 23 00:01:42 EDT 2025 Tue Aug 26 16:44:42 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Keywords | Proton magnetic resonance spectroscopy (1H-MRS) Time-domain signal processing Alzheimer's disease (AD) Brain metabolite quantification Signal-to-noise ratio (SNR) Data analysis techniques Spectral analysis |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c2535-b534f8542bfe6b095f487a42c259f3b836d9f5ba5684e7b7fff83e1d14b7beab3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ORCID | 0000-0002-7101-3824 0000-0002-8515-5858 0000-0002-4048-0817 0000-0002-6177-5163 |
PQID | 3165080715 |
PQPubID | 23479 |
PageCount | 1 |
ParticipantIDs | proquest_miscellaneous_3165080715 crossref_primary_10_1016_j_compbiomed_2025_109806 elsevier_sciencedirect_doi_10_1016_j_compbiomed_2025_109806 elsevier_clinicalkeyesjournals_1_s2_0_S0010482525001568 elsevier_clinicalkey_doi_10_1016_j_compbiomed_2025_109806 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 20250301 |
PublicationDateYYYYMMDD | 2025-03-01 |
PublicationDate_xml | – month: 03 year: 2025 text: 20250301 day: 01 |
PublicationDecade | 2020 |
PublicationTitle | Computers in biology and medicine |
PublicationYear | 2025 |
Publisher | Elsevier Ltd |
Publisher_xml | – name: Elsevier Ltd |
References | Ford, Crewther (bib5) 2016; 9 Maul, Giegling, Rujescu (bib26) 2020; 11 Brender, Kishimoto, Merkle, Reed, Hurd, Chen, Ardenkjaer-Larsen, Munasinghe, Saito, Seki, Oshima, Yamamoto, Choyke, Mitchell, Krishna (bib8) 2019; 9 Staniszewski, Polański (bib11) 2014; R. 60 Zhuang, Yang, Cordes (bib14) 2020; 41 Moffett, Arun, Ariyannur, Namboodiri (bib22) 2013; 5 Govindaraju, Young, Maudsley (bib18) 2000; 13 Harris, Saleh, Edden (bib3) 2017; 77 Fu, Klyuzhin, McKenzie, Neilson, Shahinfard, Dinelle, McKeown, Stoessl, Sossi (bib16) 2019; 23 Chang, Munsaka, Kraft-Terry, Ernst (bib23) 2013; 8 Keating, Deng, Roddey, White, Dale, Stenger, Ernst (bib6) 2010; 64 Castellano, Dias, Foerster, Li, Covolan (bib20) 2012; 45 Provencher (bib17) 1993; 30 Tanaka, Mandic (bib13) 2007; 14 Narayana (bib25) 2005; 15 Thomson, Hwa, Pasanta, Hopwood, Powell, Lawrence, Tabuenca, Arichi, Edden, Chai, Puts (bib4) 2024; 34 Tognarelli, Dawood, Shariff, Grover, Crossey, Cox, Taylor-Robinson, McPhail (bib7) 2015; 5 Zhai, Eslami, Hussein, Filali, Shalaby, Amira, Bensaali, Dakua, Abinahed, Al-Ansari, Ahmed (bib30) 2018; 27 Zhang, Shen (bib19) 2020; 314 Gajdošík, Landheer, Swanberg, Juchem (bib9) 2021; 11 Cecil (bib1) 2013; 23 Harris, MacMillan (bib2) 2023 Lee, McKeown, Wang, Chen (bib15) 2019; 66 Griffith, den Hollander, Okonkwo, O'Brien, Watts, Marson (bib21) 2008; 22 Liserre, Pinelli, Gasparotti (bib24) 2021; 10 Weinberg, Kuruva, Shim, Mullins (bib28) 2021; 59 Bertholdo, Watcharakorn, Castillo (bib29) 2013; 23 Verma, Kumar, Verma, Aggarwal, Ojha (bib27) 2016; 5 Gordon, Autry, Tang, Graham, Bok, Zhu, Villanueva-Meyer, Li, Ohilger, Abraham, Xu, Vigneron, Larson (bib10) 2020; 84 Huang, Shen, Long, Wu, Shih, Zheng, Yen, Tung, Liu (bib12) 1998; 454 Verma (10.1016/j.compbiomed.2025.109806_bib27) 2016; 5 Zhang (10.1016/j.compbiomed.2025.109806_bib19) 2020; 314 Harris (10.1016/j.compbiomed.2025.109806_bib3) 2017; 77 Castellano (10.1016/j.compbiomed.2025.109806_bib20) 2012; 45 Harris (10.1016/j.compbiomed.2025.109806_bib2) 2023 Fu (10.1016/j.compbiomed.2025.109806_bib16) 2019; 23 Narayana (10.1016/j.compbiomed.2025.109806_bib25) 2005; 15 Staniszewski (10.1016/j.compbiomed.2025.109806_bib11) 2014; R. 60 Tanaka (10.1016/j.compbiomed.2025.109806_bib13) 2007; 14 Tognarelli (10.1016/j.compbiomed.2025.109806_bib7) 2015; 5 Govindaraju (10.1016/j.compbiomed.2025.109806_bib18) 2000; 13 Gajdošík (10.1016/j.compbiomed.2025.109806_bib9) 2021; 11 Cecil (10.1016/j.compbiomed.2025.109806_bib1) 2013; 23 Huang (10.1016/j.compbiomed.2025.109806_bib12) 1998; 454 Weinberg (10.1016/j.compbiomed.2025.109806_bib28) 2021; 59 Provencher (10.1016/j.compbiomed.2025.109806_bib17) 1993; 30 Liserre (10.1016/j.compbiomed.2025.109806_bib24) 2021; 10 Bertholdo (10.1016/j.compbiomed.2025.109806_bib29) 2013; 23 Maul (10.1016/j.compbiomed.2025.109806_bib26) 2020; 11 Gordon (10.1016/j.compbiomed.2025.109806_bib10) 2020; 84 Moffett (10.1016/j.compbiomed.2025.109806_bib22) 2013; 5 Keating (10.1016/j.compbiomed.2025.109806_bib6) 2010; 64 Chang (10.1016/j.compbiomed.2025.109806_bib23) 2013; 8 Griffith (10.1016/j.compbiomed.2025.109806_bib21) 2008; 22 Thomson (10.1016/j.compbiomed.2025.109806_bib4) 2024; 34 Zhuang (10.1016/j.compbiomed.2025.109806_bib14) 2020; 41 Ford (10.1016/j.compbiomed.2025.109806_bib5) 2016; 9 Lee (10.1016/j.compbiomed.2025.109806_bib15) 2019; 66 Zhai (10.1016/j.compbiomed.2025.109806_bib30) 2018; 27 Brender (10.1016/j.compbiomed.2025.109806_bib8) 2019; 9 |
References_xml | – volume: 9 start-page: 3410 year: 2019 ident: bib8 article-title: Dynamic imaging of glucose and lactate metabolism by 13C-MRS without hyperpolarization publication-title: Sci. Rep. – volume: 14 start-page: 101 year: 2007 end-page: 104 ident: bib13 article-title: Complex empirical mode decomposition publication-title: IEEE Signal Process. Lett. – volume: 84 start-page: 2943 year: 2020 end-page: 2952 ident: bib10 article-title: A variable resolution approach for improved acquisition of hyperpolarized (13) C metabolic MRI publication-title: Magn. Reson. Med. – volume: 15 start-page: 46s year: 2005 end-page: 57s ident: bib25 article-title: Magnetic resonance spectroscopy in the monitoring of multiple sclerosis publication-title: J. Neuroimaging – volume: 5 start-page: 170 year: 2016 end-page: 178 ident: bib27 article-title: Magnetic resonance spectroscopy - revisiting the biochemical and molecular milieu of brain tumors publication-title: BBA Clin. – volume: 23 year: 2019 ident: bib16 article-title: Joint pattern analysis applied to PET DAT and VMAT2 imaging reveals new insights into Parkinson's disease induced presynaptic alterations publication-title: Neuroimage Clin – volume: 45 start-page: 1031 year: 2012 end-page: 1036 ident: bib20 article-title: NAA and NAAG variation in neuronal activation during visual stimulation publication-title: Braz. J. Med. Biol. Res. – volume: 10 start-page: 1169 year: 2021 end-page: 1200 ident: bib24 article-title: MR spectroscopy in pediatric neuroradiology publication-title: Transl. Pediatr. – volume: 64 start-page: 672 year: 2010 end-page: 679 ident: bib6 article-title: Prospective motion correction for single-voxel 1H MR spectroscopy publication-title: Magn. Reson. Med. – volume: 11 start-page: 769 year: 2020 ident: bib26 article-title: Proton magnetic resonance spectroscopy in common dementias-current status and perspectives publication-title: Front. Psychiatr. – volume: 5 start-page: 11 year: 2013 ident: bib22 article-title: N-Acetylaspartate reductions in brain injury: impact on post-injury neuroenergetics, lipid synthesis, and protein acetylation publication-title: Front. Neuroenergetics – volume: 59 start-page: 349 year: 2021 end-page: 362 ident: bib28 article-title: Clinical applications of magnetic resonance spectroscopy in brain tumors: from diagnosis to treatment publication-title: Radiol. Clin. – volume: 5 start-page: 320 year: 2015 end-page: 328 ident: bib7 article-title: Magnetic resonance spectroscopy: principles and techniques: lessons for clinicians publication-title: J Clin Exp Hepatol – volume: 454 start-page: 903 year: 1998 end-page: 995 ident: bib12 article-title: The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis publication-title: Proceedings of the Royal Society of London. Series A: Math. Phys. Eng. Sci. – volume: 27 start-page: 35 year: 2018 end-page: 45 ident: bib30 article-title: Real-time automated image segmentation technique for cerebral aneurysm on reconfigurable system-on-chip publication-title: Journal of Computational Science – volume: 22 start-page: 54 year: 2008 end-page: 60 ident: bib21 article-title: Brain N-acetylaspartate is reduced in Parkinson disease with dementia publication-title: Alzheimer Dis. Assoc. Disord. – volume: 77 start-page: 1377 year: 2017 end-page: 1389 ident: bib3 article-title: Edited 1H magnetic resonance spectroscopy in vivo: methods and metabolites publication-title: Magn. Reson. Med. – volume: 314 year: 2020 ident: bib19 article-title: Effects of noise and linewidth on in vivo analysis of glutamate at 3 T publication-title: J. Magn. Reson. – volume: 23 start-page: 359 year: 2013 end-page: 380 ident: bib29 article-title: Brain proton magnetic resonance spectroscopy: introduction and overview publication-title: Neuroimaging Clin. – volume: 8 start-page: 576 year: 2013 end-page: 593 ident: bib23 article-title: Magnetic resonance spectroscopy to assess neuroinflammation and neuropathic pain publication-title: J. Neuroimmune Pharmacol. – volume: R. 60 start-page: 354 year: 2014 end-page: 357 ident: bib11 article-title: Hankel singular value decomposition as a method of preprocessing the magnetic resonance spectroscopy publication-title: Pomiary Autom. Kontrola – start-page: 79 year: 2023 end-page: 116 ident: bib2 article-title: Chapter 4 - MRS in neuroinflammation publication-title: Advances in Magnetic Resonance Technology and Applications' – volume: 9 start-page: 14 year: 2016 ident: bib5 article-title: A comprehensive review of the (1)H-MRS metabolite spectrum in autism spectrum disorder publication-title: Front. Mol. Neurosci. – volume: 13 start-page: 129 year: 2000 end-page: 153 ident: bib18 article-title: Proton NMR chemical shifts and coupling constants for brain metabolites publication-title: NMR Biomed. – volume: 41 start-page: 3807 year: 2020 end-page: 3833 ident: bib14 article-title: A technical review of canonical correlation analysis for neuroscience applications publication-title: Hum. Brain Mapp. – volume: 11 start-page: 2094 year: 2021 ident: bib9 article-title: INSPECTOR: free software for magnetic resonance spectroscopy data inspection, processing, simulation and analysis publication-title: Sci. Rep. – volume: 30 start-page: 672 year: 1993 end-page: 679 ident: bib17 article-title: Estimation of metabolite concentrations from localized in vivo proton NMR spectra publication-title: Magn. Reson. Med. – volume: 34 year: 2024 ident: bib4 article-title: The developmental trajectory of 1H-MRS brain metabolites from childhood to adulthood publication-title: Cerebr. Cortex – volume: 66 start-page: 50 year: 2019 end-page: 60 ident: bib15 article-title: Removal of high-voltage brain stimulation artifacts from simultaneous EEG recordings publication-title: IEEE (Inst. Electr. Electron. Eng.) Trans. Biomed. Eng. – volume: 23 start-page: 381 year: 2013 end-page: 392 ident: bib1 article-title: Proton magnetic resonance spectroscopy: technique for the neuroradiologist publication-title: Neuroimaging Clin. – volume: 77 start-page: 1377 issue: 4 year: 2017 ident: 10.1016/j.compbiomed.2025.109806_bib3 article-title: Edited 1H magnetic resonance spectroscopy in vivo: methods and metabolites publication-title: Magn. Reson. Med. doi: 10.1002/mrm.26619 – volume: 10 start-page: 1169 issue: 4 year: 2021 ident: 10.1016/j.compbiomed.2025.109806_bib24 article-title: MR spectroscopy in pediatric neuroradiology publication-title: Transl. Pediatr. doi: 10.21037/tp-20-445 – volume: 9 start-page: 14 year: 2016 ident: 10.1016/j.compbiomed.2025.109806_bib5 article-title: A comprehensive review of the (1)H-MRS metabolite spectrum in autism spectrum disorder publication-title: Front. Mol. Neurosci. doi: 10.3389/fnmol.2016.00014 – volume: 15 start-page: 46s issue: 4 Suppl year: 2005 ident: 10.1016/j.compbiomed.2025.109806_bib25 article-title: Magnetic resonance spectroscopy in the monitoring of multiple sclerosis publication-title: J. Neuroimaging – start-page: 79 year: 2023 ident: 10.1016/j.compbiomed.2025.109806_bib2 article-title: Chapter 4 - MRS in neuroinflammation doi: 10.1016/B978-0-323-91771-1.00012-5 – volume: 314 year: 2020 ident: 10.1016/j.compbiomed.2025.109806_bib19 article-title: Effects of noise and linewidth on in vivo analysis of glutamate at 3 T publication-title: J. Magn. Reson. doi: 10.1016/j.jmr.2020.106732 – volume: 84 start-page: 2943 issue: 6 year: 2020 ident: 10.1016/j.compbiomed.2025.109806_bib10 article-title: A variable resolution approach for improved acquisition of hyperpolarized (13) C metabolic MRI publication-title: Magn. Reson. Med. doi: 10.1002/mrm.28421 – volume: 13 start-page: 129 issue: 3 year: 2000 ident: 10.1016/j.compbiomed.2025.109806_bib18 article-title: Proton NMR chemical shifts and coupling constants for brain metabolites publication-title: NMR Biomed. doi: 10.1002/1099-1492(200005)13:3<129::AID-NBM619>3.0.CO;2-V – volume: 45 start-page: 1031 issue: 11 year: 2012 ident: 10.1016/j.compbiomed.2025.109806_bib20 article-title: NAA and NAAG variation in neuronal activation during visual stimulation publication-title: Braz. J. Med. Biol. Res. doi: 10.1590/S0100-879X2012007500128 – volume: 22 start-page: 54 issue: 1 year: 2008 ident: 10.1016/j.compbiomed.2025.109806_bib21 article-title: Brain N-acetylaspartate is reduced in Parkinson disease with dementia publication-title: Alzheimer Dis. Assoc. Disord. doi: 10.1097/WAD.0b013e3181611011 – volume: 64 start-page: 672 issue: 3 year: 2010 ident: 10.1016/j.compbiomed.2025.109806_bib6 article-title: Prospective motion correction for single-voxel 1H MR spectroscopy publication-title: Magn. Reson. Med. doi: 10.1002/mrm.22448 – volume: 41 start-page: 3807 issue: 13 year: 2020 ident: 10.1016/j.compbiomed.2025.109806_bib14 article-title: A technical review of canonical correlation analysis for neuroscience applications publication-title: Hum. Brain Mapp. doi: 10.1002/hbm.25090 – volume: 454 start-page: 903 year: 1998 ident: 10.1016/j.compbiomed.2025.109806_bib12 article-title: The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis publication-title: Proceedings of the Royal Society of London. Series A: Math. Phys. Eng. Sci. doi: 10.1098/rspa.1998.0193 – volume: 14 start-page: 101 issue: 2 year: 2007 ident: 10.1016/j.compbiomed.2025.109806_bib13 article-title: Complex empirical mode decomposition publication-title: IEEE Signal Process. Lett. doi: 10.1109/LSP.2006.882107 – volume: 30 start-page: 672 issue: 6 year: 1993 ident: 10.1016/j.compbiomed.2025.109806_bib17 article-title: Estimation of metabolite concentrations from localized in vivo proton NMR spectra publication-title: Magn. Reson. Med. doi: 10.1002/mrm.1910300604 – volume: 11 start-page: 769 year: 2020 ident: 10.1016/j.compbiomed.2025.109806_bib26 article-title: Proton magnetic resonance spectroscopy in common dementias-current status and perspectives publication-title: Front. Psychiatr. doi: 10.3389/fpsyt.2020.00769 – volume: 11 start-page: 2094 issue: 1 year: 2021 ident: 10.1016/j.compbiomed.2025.109806_bib9 article-title: INSPECTOR: free software for magnetic resonance spectroscopy data inspection, processing, simulation and analysis publication-title: Sci. Rep. doi: 10.1038/s41598-021-81193-9 – volume: 23 start-page: 381 issue: 3 year: 2013 ident: 10.1016/j.compbiomed.2025.109806_bib1 article-title: Proton magnetic resonance spectroscopy: technique for the neuroradiologist publication-title: Neuroimaging Clin. doi: 10.1016/j.nic.2012.10.003 – volume: 5 start-page: 320 issue: 4 year: 2015 ident: 10.1016/j.compbiomed.2025.109806_bib7 article-title: Magnetic resonance spectroscopy: principles and techniques: lessons for clinicians publication-title: J Clin Exp Hepatol doi: 10.1016/j.jceh.2015.10.006 – volume: 23 start-page: 359 issue: 3 year: 2013 ident: 10.1016/j.compbiomed.2025.109806_bib29 article-title: Brain proton magnetic resonance spectroscopy: introduction and overview publication-title: Neuroimaging Clin. doi: 10.1016/j.nic.2012.10.002 – volume: 59 start-page: 349 issue: 3 year: 2021 ident: 10.1016/j.compbiomed.2025.109806_bib28 article-title: Clinical applications of magnetic resonance spectroscopy in brain tumors: from diagnosis to treatment publication-title: Radiol. Clin. doi: 10.1016/j.rcl.2021.01.004 – volume: 34 issue: 3 year: 2024 ident: 10.1016/j.compbiomed.2025.109806_bib4 article-title: The developmental trajectory of 1H-MRS brain metabolites from childhood to adulthood publication-title: Cerebr. Cortex doi: 10.1093/cercor/bhae046 – volume: 9 start-page: 3410 issue: 1 year: 2019 ident: 10.1016/j.compbiomed.2025.109806_bib8 article-title: Dynamic imaging of glucose and lactate metabolism by 13C-MRS without hyperpolarization publication-title: Sci. Rep. doi: 10.1038/s41598-019-38981-1 – volume: 5 start-page: 170 year: 2016 ident: 10.1016/j.compbiomed.2025.109806_bib27 article-title: Magnetic resonance spectroscopy - revisiting the biochemical and molecular milieu of brain tumors publication-title: BBA Clin. doi: 10.1016/j.bbacli.2016.04.002 – volume: 27 start-page: 35 year: 2018 ident: 10.1016/j.compbiomed.2025.109806_bib30 article-title: Real-time automated image segmentation technique for cerebral aneurysm on reconfigurable system-on-chip publication-title: Journal of Computational Science doi: 10.1016/j.jocs.2018.05.002 – volume: 8 start-page: 576 issue: 3 year: 2013 ident: 10.1016/j.compbiomed.2025.109806_bib23 article-title: Magnetic resonance spectroscopy to assess neuroinflammation and neuropathic pain publication-title: J. Neuroimmune Pharmacol. doi: 10.1007/s11481-013-9460-x – volume: R. 60 start-page: 354 issue: 6 year: 2014 ident: 10.1016/j.compbiomed.2025.109806_bib11 article-title: Hankel singular value decomposition as a method of preprocessing the magnetic resonance spectroscopy publication-title: Pomiary Autom. Kontrola – volume: 66 start-page: 50 issue: 1 year: 2019 ident: 10.1016/j.compbiomed.2025.109806_bib15 article-title: Removal of high-voltage brain stimulation artifacts from simultaneous EEG recordings publication-title: IEEE (Inst. Electr. Electron. Eng.) Trans. Biomed. Eng. – volume: 5 start-page: 11 year: 2013 ident: 10.1016/j.compbiomed.2025.109806_bib22 article-title: N-Acetylaspartate reductions in brain injury: impact on post-injury neuroenergetics, lipid synthesis, and protein acetylation publication-title: Front. Neuroenergetics doi: 10.3389/fnene.2013.00011 – volume: 23 year: 2019 ident: 10.1016/j.compbiomed.2025.109806_bib16 article-title: Joint pattern analysis applied to PET DAT and VMAT2 imaging reveals new insights into Parkinson's disease induced presynaptic alterations publication-title: Neuroimage Clin doi: 10.1016/j.nicl.2019.101856 |
SSID | ssj0004030 |
Score | 2.4028108 |
Snippet | Proton magnetic resonance spectroscopy (1H-MRS) is a valuable non-invasive method for quantifying brain metabolites. Most MRS spectra are pre-processed by... AbstractProton magnetic resonance spectroscopy ( 1H-MRS) is a valuable non-invasive method for quantifying brain metabolites. Most MRS spectra are... |
SourceID | proquest crossref elsevier |
SourceType | Aggregation Database Index Database Publisher |
StartPage | 109806 |
SubjectTerms | Alzheimer's disease (AD) Brain metabolite quantification Data analysis techniques Internal Medicine Other Proton magnetic resonance spectroscopy (1H-MRS) Signal-to-noise ratio (SNR) Spectral analysis Time-domain signal processing |
Title | Assessment of 1H-MRS spectra via multiset canonical correlation analysis and empirical mode decomposition |
URI | https://www.clinicalkey.com/#!/content/1-s2.0-S0010482525001568 https://www.clinicalkey.es/playcontent/1-s2.0-S0010482525001568 https://dx.doi.org/10.1016/j.compbiomed.2025.109806 https://www.proquest.com/docview/3165080715 |
Volume | 187 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV3PS-QwFA7iwuJFXFdxdFey4LU6bV4mLXsaZGfHlfGwq-AtJE0CFZwZ7OjRv933mlTZ1YOwl9KmTZM-Xt8P8n0vjB05o2r0AsPMlSZkAM5kmIfIrATpiJoZJBA5eXYxml7Br2t5vcZOey4MwSqT7Y82vbPWqeUkSfNk2TTE8cVUAl-MTpz4wET4BVCk5cePLzAPGIpIQ0F7Q08nNE_EeBFsO9LcMVMsJNVWKmnvo7dd1D_GuvNAky22mUJHPo6z-8TW_HybfZylxfHPrBk_V9nki8DzaTb7_Yd3VMo7wx8awzv0YOtXHOW56AiRvKbdOSIejptUoARPHPe3y6YrH8JpsxzuPH1FQnjtsKvJj8vTaZZ2UsjqQgqZWSkglBIKG_zIYlQVME8xUODdKghbipGrgrQGpQheWRVCKIXPXQ5WWW-s2GXrOC-_x7io3LDAljoHBZWtLVQBQxTvvAOhlB2wvBeeXsaCGbpHkt3oF4FrEriOAh-wqpey7gmhaMI0WvV39FVv9fVt-hdbneu20EP9Sl8G7Ptzz79U7p3jfuvVQeMfScssZu4X960WOUW9GLrJ_f8a4YBt0FUEvH1h66u7e_8VI6CVPexUHI_l5Och-zA-O59ePAGXiAjG |
linkProvider | Elsevier |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1NT9wwEB3BIpVeqpaCukDBSL1GbGJ7k4jTCoHCx-6hBYmbZce2FKTursjS389M7IDackDiFjma2BmNZ8byezMAP6zOa4wCo8QW2idCWJ3gOUQmhZCWqJleCiInT2fj6lZc3sm7NTjtuTAEq4y-P_j0zlvHkeOozeNl0xDHF48S-GEM4sQHLtZhg6pTyQFsTC6uqtkLPXLEAxMFXQ4JREBPgHkRcjsw3fGwmEkqr1RQ-6PXo9Q__roLQuef4VPMHtkkLPALrLn5FnyYxvvxr9BMngttsoVnaZVMf_5iHZvyQbM_jWYdgLB1K4YqXXScSFZTg44AiWM61ijBB8vc72XTVRBh1C-HWUd_EUFe23B7fnZzWiWxmUJSZ5LLxEgufCFFZrwbG0ysPB5VtMjwbem5KfjYll4ajYoULje5977gLrWpMLlx2vAdGOC63DdgvLSjDEfqVOSiNLURpccsxVlnBc9zM4S0V55ahpoZqgeT3asXhStSuAoKH0LZa1n1nFD0Ygod-xtk89dkXRu3Y6tS1WZqpP4zmSGcPEv-ZXVvnPeoNweFm5JuWvTcLR5bxVNKfDF7k7vvmuEQNqub6bW6vphd7cFHehPwb_swWD08uu-YEK3MQTT4J2PQCpE |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Assessment+of+1H-MRS+spectra+via+multiset+canonical+correlation+analysis+and+empirical+mode+decomposition&rft.jtitle=Computers+in+biology+and+medicine&rft.au=Ahdi%2C+Alieh&rft.au=Ensworth%2C+Alex&rft.au=Schulz%2C+Bretta+Russell&rft.au=MacMillan%2C+Erin&rft.date=2025-03-01&rft.pub=Elsevier+Ltd&rft.issn=0010-4825&rft.volume=187&rft_id=info:doi/10.1016%2Fj.compbiomed.2025.109806&rft.externalDocID=S0010482525001568 |
thumbnail_m | http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=https%3A%2F%2Fcdn.clinicalkey.com%2Fck-thumbnails%2F00104825%2FS0010482525X00020%2Fcov150h.gif |