Clinical evaluation of a new multi-purpose disinfecting solution in symptomatic wearers of silicone hydrogel contact lenses
Background: The purpose of this study was to evaluate the safety and efficacy of a new multi-purpose disinfecting solution containing a diblock copolymer, poly(oxyethylene)-poly(oxybutylene), designed to improve the wetting properties of silicone hydrogel lenses in patients with symptoms of discomfo...
Saved in:
Published in | Clinical optometry (Auckland) Vol. 4; no. default; pp. 13 - 24 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
Macclesfield
Taylor & Francis Ltd
01.07.2012
Dove Medical Press |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Background: The purpose of this study was to evaluate the safety and efficacy of a new multi-purpose disinfecting solution containing a diblock copolymer, poly(oxyethylene)-poly(oxybutylene), designed to improve the wetting properties of silicone hydrogel lenses in patients with symptoms of discomfort. Methods: This 30-day, randomized, concurrently controlled, double-masked, multi-site study involved 589 subjects at 42 investigational sites in the US. Existing symptomatic lens wearers were randomly assigned to either regimen 1 (OPTI-FREE® PureMoist®, Alcon Laboratories Inc,) a newly developed formulation containing the diblock copolymer), or regimen 2 (renu® fresh™ multi-purpose solution Bausch + Lomb, Inc). On days 0, 14 and 30, subjects assessed acceptability and comfort using seven Likert-type questions, rated the intensity of ocular symptoms (comfort, dryness, irritation, scratchiness, burning, stinging) on a visual analog scale (0–100), as well as reported lens wearing time, comfortable lens wearing time, and rewetting drop frequency. The investigators assessed slit-lamp findings (including circumlimbal conjunctival lissamine green staining and corneal fluorescein staining), on-eye lens surface wettability and deposits, visual acuity, and adverse events. Results: Differences favoring regimen 1 were noted on Day 30 for the primary Likert statement “I can comfortably wear my lenses” (P= 0.047) and for comfortable lens wear time (P = 0.041). Symptoms of ocular scratchiness, ocular burning, and ocular stinging were all rated lower after 30 days of use by subjects using regimen 1 compared with those using regimen 2 (P ≤ 0.024). Circumlimbal conjunctival staining (sum score) was significantly lower with regimen 1 (P < 0.0001). Other parameters did not show any difference between the two treatment regimens. Conclusion: This study shows that the new multi-purpose disinfecting solution is safe and effective when used by symptomatic silicone hydrogel contact lens wearers. By improving symptoms of scratchiness, burning, stinging, and comfortable wear time, and decreasing circumlimbal conjunctival staining, the new multi-purpose disinfecting solution enhances the patient's wearing experience and helps maintain optimal lens performance. |
---|---|
AbstractList | Glenn S Corbin,1 David L Kading,2 Sean M Powell,3 Brian D Rosenblatt,4 Glenda B Secor,5 Cecile A Maissa,6 Renee J Garofalo71Wyomissing Optometric Center, Wyomissing, PA, USA; 2Specialty Eyecare Group, Kirkland, WA, USA; 320/20 Eye Care LLC, Lenexa, KS, USA; 4Rosenblatt Family Eye Care Associates, Raritan, NJ, USA; 5Huntington Beach, CA, USA; 6OTG Research and Consultancy, London, UK; 7Alcon Research Ltd, Fort Worth, TX, USABackground: The purpose of this study was to evaluate the safety and efficacy of a new multi-purpose disinfecting solution containing a diblock copolymer, poly(oxyethylene)-poly(oxybutylene), designed to improve the wetting properties of silicone hydrogel lenses in patients with symptoms of discomfort.Methods: This 30-day, randomized, concurrently controlled, double-masked, multi-site study involved 589 subjects at 42 investigational sites in the US. Existing symptomatic lens wearers were randomly assigned to either regimen 1 (OPTI-FREE® PureMoist®, Alcon Laboratories Inc,) a newly developed formulation containing the diblock copolymer), or regimen 2 (renu® fresh™ multi-purpose solution Bausch + Lomb, Inc). On days 0, 14 and 30, subjects assessed acceptability and comfort using seven Likert-type questions, rated the intensity of ocular symptoms (comfort, dryness, irritation, scratchiness, burning, stinging) on a visual analog scale (0–100), as well as reported lens wearing time, comfortable lens wearing time, and rewetting drop frequency. The investigators assessed slit-lamp findings (including circumlimbal conjunctival lissamine green staining and corneal fluorescein staining), on-eye lens surface wettability and deposits, visual acuity, and adverse events.Results: Differences favoring regimen 1 were noted on Day 30 for the primary Likert statement “I can comfortably wear my lenses” (P = 0.047) and for comfortable lens wear time (P = 0.041). Symptoms of ocular scratchiness, ocular burning, and ocular stinging were all rated lower after 30 days of use by subjects using regimen 1 compared with those using regimen 2 (P ≤ 0.024). Circumlimbal conjunctival staining (sum score) was significantly lower with regimen 1 (P < 0.0001). Other parameters did not show any difference between the two treatment regimens.Conclusion: This study shows that the new multi-purpose disinfecting solution is safe and effective when used by symptomatic silicone hydrogel contact lens wearers. By improving symptoms of scratchiness, burning, stinging, and comfortable wear time, and decreasing circumlimbal conjunctival staining, the new multi-purpose disinfecting solution enhances the patient's wearing experience and helps maintain optimal lens performance.Keywords: multi-purpose disinfecting solution; subjective comfort; silicone hydrogel contact lenses Background: The purpose of this study was to evaluate the safety and efficacy of a new multi-purpose disinfecting solution containing a diblock copolymer, poly(oxyethylene)-poly(oxybutylene), designed to improve the wetting properties of silicone hydrogel lenses in patients with symptoms of discomfort. Methods: This 30-day, randomized, concurrently controlled, double-masked, multi-site study involved 589 subjects at 42 investigational sites in the US. Existing symptomatic lens wearers were randomly assigned to either regimen 1 (OPTI-FREE® PureMoist®, Alcon Laboratories Inc,) a newly developed formulation containing the diblock copolymer), or regimen 2 (renu® fresh™ multi-purpose solution Bausch + Lomb, Inc). On days 0, 14 and 30, subjects assessed acceptability and comfort using seven Likert-type questions, rated the intensity of ocular symptoms (comfort, dryness, irritation, scratchiness, burning, stinging) on a visual analog scale (0–100), as well as reported lens wearing time, comfortable lens wearing time, and rewetting drop frequency. The investigators assessed slit-lamp findings (including circumlimbal conjunctival lissamine green staining and corneal fluorescein staining), on-eye lens surface wettability and deposits, visual acuity, and adverse events. Results: Differences favoring regimen 1 were noted on Day 30 for the primary Likert statement “I can comfortably wear my lenses” (P= 0.047) and for comfortable lens wear time (P = 0.041). Symptoms of ocular scratchiness, ocular burning, and ocular stinging were all rated lower after 30 days of use by subjects using regimen 1 compared with those using regimen 2 (P ≤ 0.024). Circumlimbal conjunctival staining (sum score) was significantly lower with regimen 1 (P < 0.0001). Other parameters did not show any difference between the two treatment regimens. Conclusion: This study shows that the new multi-purpose disinfecting solution is safe and effective when used by symptomatic silicone hydrogel contact lens wearers. By improving symptoms of scratchiness, burning, stinging, and comfortable wear time, and decreasing circumlimbal conjunctival staining, the new multi-purpose disinfecting solution enhances the patient's wearing experience and helps maintain optimal lens performance. |
Author | Rosenblatt Secor Corbin Garofalo, Renee Powell Maissa, Cecile Kading, David |
Author_xml | – sequence: 1 givenname: Renee surname: Garofalo fullname: Garofalo, Renee – sequence: 2 givenname: Cecile surname: Maissa fullname: Maissa, Cecile – sequence: 3 surname: Corbin fullname: Corbin – sequence: 4 givenname: David surname: Kading fullname: Kading, David – sequence: 5 surname: Powell fullname: Powell – sequence: 6 surname: Rosenblatt fullname: Rosenblatt – sequence: 7 surname: Secor fullname: Secor |
BookMark | eNpNUV1rFDEUDVLBWvvkHwj4KFPzncmjLFoLhS1Yn0P2TrJmySZjMmNZ_PPOdEV6Xu4H55574LxFF7lkj9B7Sm4YFfrT9uFxe_OdUy7oK3RJqTYd05JdvOjfoOvWDmRBT4ig5hL92aSYI7iE_W-XZjfFknEJ2OHsn_BxTlPsxrmOpXk8xBZz8DDFvMetpPmZHDNup-M4leNyDPjJu-prWzVaTBEWj_jnaahl7xNepsnBhJPPzbd36HVwqfnrf_UK_fj65XHzrbvf3t5tPt93wCSbOhCKaDDSSdIzTp1RSu3AaGoCY2ZHdgGkV9J5oDsutBi8kAOVzIDWoAD4Fbo76w7FHexY49HVky0u2udFqXvr6uI9eSuDBNlzQ9kQBO917zkEpohiuje6X7U-nLXGWn7Nvk32UOaaF_uWraBKcLawPp5ZUEtr1Yf_Xymxa1h2Dcuew-J_AVOPihg |
ContentType | Journal Article |
Copyright | 2012. This work is licensed under https://creativecommons.org/licenses/by-nc/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. |
Copyright_xml | – notice: 2012. This work is licensed under https://creativecommons.org/licenses/by-nc/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. |
DBID | AAYXX CITATION 3V. 7RQ 7RV 7XB 8FI 8FJ 8FK 8G5 ABUWG AFKRA AZQEC BENPR CCPQU DWQXO FYUFA GHDGH GNUQQ GUQSH KB0 M2O MBDVC NAPCQ PHGZM PHGZT PIMPY PKEHL PPXIY PQEST PQQKQ PQUKI PRINS Q9U U9A DOA |
DOI | 10.2147/OPTO.S31341 |
DatabaseName | CrossRef ProQuest Central (Corporate) Career & Technical Education Database Nursing & Allied Health Database ProQuest Central (purchase pre-March 2016) Hospital Premium Collection Hospital Premium Collection (Alumni Edition) ProQuest Central (Alumni) (purchase pre-March 2016) ProQuest Research Library ProQuest Central (Alumni) ProQuest Central UK/Ireland ProQuest Central Essentials ProQuest Central ProQuest One Community College ProQuest Central Korea Health Research Premium Collection Health Research Premium Collection (Alumni) ProQuest Central Student ProQuest Research Library Nursing & Allied Health Database (Alumni Edition) Research Library Research Library (Corporate) Nursing & Allied Health Premium ProQuest Central Premium ProQuest One Academic Publicly Available Content Database ProQuest One Academic Middle East (New) ProQuest One Health & Nursing ProQuest One Academic Eastern Edition (DO NOT USE) ProQuest One Academic ProQuest One Academic UKI Edition ProQuest Central China ProQuest Central Basic DOAJ Directory of Open Access Journals |
DatabaseTitle | CrossRef Publicly Available Content Database Research Library Prep ProQuest Central Student ProQuest One Academic Middle East (New) ProQuest Central Essentials ProQuest Central (Alumni Edition) ProQuest One Community College ProQuest One Health & Nursing Research Library (Alumni Edition) ProQuest Central China ProQuest Central Health Research Premium Collection ProQuest Central Korea ProQuest Research Library ProQuest Central (New) Career and Technical Education (Alumni Edition) ProQuest Central Basic ProQuest One Academic Eastern Edition ProQuest Nursing & Allied Health Source ProQuest Hospital Collection Health Research Premium Collection (Alumni) ProQuest Hospital Collection (Alumni) Nursing & Allied Health Premium ProQuest Career and Technical Education ProQuest One Academic UKI Edition ProQuest Nursing & Allied Health Source (Alumni) ProQuest One Academic ProQuest One Academic (New) ProQuest Central (Alumni) |
DatabaseTitleList | Publicly Available Content Database |
Database_xml | – sequence: 1 dbid: DOA name: DOAJ Directory of Open Access Journals url: https://www.doaj.org/ sourceTypes: Open Website – sequence: 2 dbid: BENPR name: ProQuest Central url: https://www.proquest.com/central sourceTypes: Aggregation Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1179-2752 |
EndPage | 24 |
ExternalDocumentID | oai_doaj_org_article_5f5c583912df43878e3cf2606278978c 10_2147_OPTO_S31341 |
GroupedDBID | 0YH 53G 5VS 7RQ 7RV 8FI 8FJ 8G5 AAYXX ABUWG ADBBV AFKRA ALIPV ALMA_UNASSIGNED_HOLDINGS AOIJS AZQEC BCNDV BENPR BKEYQ BPHCQ BVXVI C1A CCPQU CITATION DWQXO FYUFA GNUQQ GROUPED_DOAJ GUQSH HYE IAO IHR IHW IPNFZ ITC KQ8 M2O M~E NAPCQ OK1 P2P PGMZT PHGZM PHGZT PIMPY PQQKQ PROAC RIG RPM TDBHL TR2 UKHRP VDV 3V. 7XB 8FK MBDVC PKEHL PPXIY PQEST PQUKI PRINS Q9U U9A PUEGO |
ID | FETCH-LOGICAL-c252t-c4607c95a508231a9666bc9719f229b0bfc5e65aec1b3474de45d1529c77c6cc3 |
IEDL.DBID | DOA |
ISSN | 1179-2752 |
IngestDate | Wed Aug 27 01:31:48 EDT 2025 Mon Jul 14 08:18:25 EDT 2025 Tue Jul 01 03:04:32 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | default |
Language | English |
License | http://creativecommons.org/licenses/by-nc/3.0 |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c252t-c4607c95a508231a9666bc9719f229b0bfc5e65aec1b3474de45d1529c77c6cc3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 |
OpenAccessLink | https://doaj.org/article/5f5c583912df43878e3cf2606278978c |
PQID | 2222216432 |
PQPubID | 3933182 |
PageCount | 12 |
ParticipantIDs | doaj_primary_oai_doaj_org_article_5f5c583912df43878e3cf2606278978c proquest_journals_2222216432 crossref_primary_10_2147_OPTO_S31341 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2012-07-01 |
PublicationDateYYYYMMDD | 2012-07-01 |
PublicationDate_xml | – month: 07 year: 2012 text: 2012-07-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | Macclesfield |
PublicationPlace_xml | – name: Macclesfield |
PublicationTitle | Clinical optometry (Auckland) |
PublicationYear | 2012 |
Publisher | Taylor & Francis Ltd Dove Medical Press |
Publisher_xml | – name: Taylor & Francis Ltd – name: Dove Medical Press |
SSID | ssj0000800419 |
Score | 1.8358253 |
Snippet | Background: The purpose of this study was to evaluate the safety and efficacy of a new multi-purpose disinfecting solution containing a diblock copolymer,... Glenn S Corbin,1 David L Kading,2 Sean M Powell,3 Brian D Rosenblatt,4 Glenda B Secor,5 Cecile A Maissa,6 Renee J Garofalo71Wyomissing Optometric Center,... |
SourceID | doaj proquest crossref |
SourceType | Open Website Aggregation Database Index Database |
StartPage | 13 |
SubjectTerms | Contact lenses Hydrogels |
SummonAdditionalLinks | – databaseName: ProQuest Central dbid: BENPR link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV3fa9swEBZdCmMvo2s3mvUHeuir21qWbOuptKWhDJaGLYG8GfsspYHMziKXUvrP905RWkZhfrSFBXenu0-603eMnQgfRk0elcQzJK2g_K6AKK8rBMApaAO-yneY3k7kj6mahgM3F8oqNz7RO-q6BTojPxP0ILZPxMXyb0Rdoyi7GlpofGDb6ILzvMe2r26Go1-vpyyEh2Ss1xfzqCXP2d1ofHf6OyEes39CkWfsf-eQfZQZ7LDPAR7yy7U-v7At0-yyjz9DAnyPPQcezwV_o-nmreUlR3jMfXVgtETZtc7weu5CqVUz4xsT4_OGu6c_y671XK380Te0dvQPN1-gWTSG3z_Vq3ZmFpzq2EvoOEYmZ9xXNhncjK9vo9A_IQKhRBeBTM8z0KpUlE6LS9zZpBXoLNZWCF2dVxaUSVVpIK4SmcnaSFVjPNeQZZACJN9Yr8Fp9xnXIgYtlYLcapnkJYJKABEbY421qOY-O9mIsliuaTIK3F6QxAuSeLGWeJ9dkZhfhxC3tX_RrmZFWCqFsgoU4rZY1BbnynKTgMVtV0qXdrMc-uxwo6QiLDhXvJnH9_9_PmCfEPOEittD1utWD-YIcUVXHQfjeQFoes-C priority: 102 providerName: ProQuest |
Title | Clinical evaluation of a new multi-purpose disinfecting solution in symptomatic wearers of silicone hydrogel contact lenses |
URI | https://www.proquest.com/docview/2222216432 https://doaj.org/article/5f5c583912df43878e3cf2606278978c |
Volume | 4 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1dS8MwFA06QXwRP3F-jDz4Wl3TpG0enTiG4BTdQJ9Ke5voZHZjrcjwz3uTZn7ggy_2sZSmnJvmnEtuziXkmFkaVbGXGp8hrpnZ32XgxXmGAjgEqcBW-fbD3pBf3ov7b62-TE1YbQ9cA3cqtACBLO6zXPMgjmIVgEYRHpojnFEMZvVFzvuWTD07HcRtVw9jeeaxSLD6cJ5py3N6fTO4PrkLjJfZDzqyrv2_FmXLNN0Nsu4kIj2rP22TLKlii6xeuU3wbfLuvDzH9Muqm040TSlKZGorBL0p4jcpFc1HpSu3Kh7pYprRUUHL-cu0mli_Vvpmm1qX5h3laIxTo1D0aZ7PJo9qTE0tewoVRXYqVblDht2LwXnPcz0UPGCCVR7wsB2BFKkwW2p-itlNmIGMfKkZk1k70yBUKFIFfhbwiOeKixw5XUIUQQgQ7JJGgcPuESqZD5ILAbGWGIkUhSUA85XSSmsMdZMcL6BMprVVRoIphkE8MYgnNeJN0jEwfz5i_K3tDYx64qKe_BX1JjlcBClxP12ZMHNh-hew_f8Y44CsoTpytbmHpFHNXtURKpAqa5Hl9kOvRVY6F_2b25adeh_gUNn- |
linkProvider | Directory of Open Access Journals |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Nb9QwEB2VrQRcEJ9iSwEfyjF049hJfECIQqstbbcVbKXeQjKxl5WWZLsOqlb8J34j48RphZC4NccksqXxs-fZM34DsMNbN6rTIHc6Q8JwF9_lGKRlQQQ4RqWxzfKdxONz8flCXmzA7_4ujEur7NfEdqEua3Rn5LvcPcTtI_5-eRm4qlEuutqX0OhgcaTXV7Rls-8OP9H4vuH8YH_6cRz4qgIBcsmbAEU8SlDJXLogU5gT348LVEmoDOeqGBUGpY5lrjEsIpGIUgtZkpdTmCQYI0bU7h3YFFE84gPY3NufnH25PtVx_EuEqrsI6EoA7Z6eTU_ffo2cbtpfrq-tEPCPA2i92sFDeODpKPvQ4ecRbOjqMdw98QH3J_DL64Yu2I0sOKsNyxnRcdZmIwZLGqvaalbOrU_tqmashzSbV8yufyybutWGZVdtAW3r2rDzBcGw0uz7ulzVM71gLm8-x4aRJ7TaPoXzW7HsMxhU1O1zYIqHqISUmBolojQnEovIQ62NNoZgNYSd3pTZspPlyGg74yyeOYtnncWHsOfMfP2L09JuX9SrWeanZiaNREk8MeSlob6SVEdoaJsXu0vCSYpD2O4HKfMT3GY3cNz6_-fXcG88PTnOjg8nRy_gPvEtn-27DYNm9VO_JE7TFK88kBh8u23s_gHeaAvg |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Nb9QwEB2VrVRxQXyKhQI-lGPYxomT-FAhSrtqKWxX0Eq9hWRib1daku0mqFrxz_h1zCROK4TErTkmkS3NPHveeMYzADuyNaMm8TKuMxRayfFdiV5S5ESAI9QG2yzfSXR0Hn66UBcb8Lu_C8Nplf2e2G7URYV8Rj6S_BC3D-TIurSI6cH4_fLK4w5SHGnt22l0EDkx62ty3-q94wPS9Vspx4dnH48812HAQ6lk42EY7caoVaY44ORnxP2jHHXsayulzndzi8pEKjPo50EYh4UJVUEWT2McY4QY0Lj3YDNmr2gAm_uHk-nXmxMe5mKhr7tLgdwOaHQ6PTt99y3gGmp_mcG2W8A_xqC1cOOH8MBRU_Ghw9Ij2DDlY9j64oLvT-CXqyG6ELclwkVlRSaImos2M9Fbkt6q2ohiXrs0r3ImeniLeSnq9Y9lU7V1YsV120y75jHq-YIgWRpxuS5W1cwsBOfQZ9gIsoq1qZ_C-Z1I9hkMSpr2OQgtfdShUphYHQZJRoQWUfrGWGMtQWwIO70o02VXoiMl14YlnrLE007iQ9hnMd_8wnW12xfVapa6ZZoqq1ARZ_RlYWmuODEBWnL5Ir4wHCc4hO1eSalb7HV6C80X___8BrYIs-nn48nJS7hP1Msl_m7DoFn9NK-I3jT5a4cjAd_vGrp_APasEBU |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Clinical+evaluation+of+a+new+multi-purpose+disinfecting+solution+in+symptomatic+wearers+of+silicone+hydrogel+contact+lenses&rft.jtitle=Clinical+optometry+%28Auckland%29&rft.au=Garofalo%2C+Renee&rft.au=Maissa%2C+Cecile&rft.au=Corbin&rft.au=Kading%2C+David&rft.date=2012-07-01&rft.issn=1179-2752&rft.eissn=1179-2752&rft.spage=13&rft_id=info:doi/10.2147%2FOPTO.S31341&rft.externalDBID=n%2Fa&rft.externalDocID=10_2147_OPTO_S31341 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1179-2752&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1179-2752&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1179-2752&client=summon |