SU-E-T-89: Characterization of Dental Restoration Material for Cs-137 Radiation Dosimetry

The purpose of this work is to characterize the radiation-induced thermoluminescence properties of a dental restoration material and to see if the material might be feasible for use in retrospective radiation dosimetry. Retrospective, or accidental, dosimetry is the study of using nearby materials t...

Full description

Saved in:
Bibliographic Details
Published inMedical physics (Lancaster) Vol. 39; no. 6Part11; p. 3723
Main Authors Ratliff, S, Gustafson, B, Barry, K
Format Journal Article
LanguageEnglish
Published United States 01.06.2012
Subjects
Online AccessGet more information

Cover

Loading…
Abstract The purpose of this work is to characterize the radiation-induced thermoluminescence properties of a dental restoration material and to see if the material might be feasible for use in retrospective radiation dosimetry. Retrospective, or accidental, dosimetry is the study of using nearby materials to measure radiation received by individuals. In this project we obtained samples of Ivoclar Vivadent e.max CAD material, a glass-ceramic used for making dental restorations such as full or partial crowns. The samples were machined into square chips .32 cm × .32 cm × .089 cm and annealed in the same furnace used by the dentist. The samples were exposed to a Cs-137 source using a PMMA source holder and then read in a Harshaw 3500 TLD reader. The samples were read without nitrogen gas flux using heating rates of 5 degrees C/s or 10 degrees C/s up to a maximum temperature of 400 degrees Celsius. The glow curves were analyzed using Systat PeakFIT peak-fitting software and Microsoft Excel spreadsheets. The authors gratefully thank Dr. Aaron Imdieke and the staff of River City Dental, St. Cloud, MN for the dental restoration materials and the use of their dental furnace. A sample subjected to a radiation exposure of .04 C/kg exhibits a glow curve with a prominent peak at approximately 140 degrees Celsius, which is well-modeled by the first order glow curve deconvolution formula developed by Kitis, Gomez-Ros, and Tuyn. The activation energy corresponding to this peak is approximately 1 eV. The thermoluminescent signal fades with time after exposure. Ivoclar Vivadent e.max CAD dental restoration material has the potential to be used as a material for retrospective Cs-137 radiation dosimetry. Future work could look at its thermoluminescent dosimetry properties in more detail and also at other dental restoration materials. The authors would like to thank Dr. Aaron Imdieke and the staff of River City Dental, St. Cloud, MN, for the donation of scrap dental restoration materials and the use of their dental furnace.
AbstractList The purpose of this work is to characterize the radiation-induced thermoluminescence properties of a dental restoration material and to see if the material might be feasible for use in retrospective radiation dosimetry. Retrospective, or accidental, dosimetry is the study of using nearby materials to measure radiation received by individuals. In this project we obtained samples of Ivoclar Vivadent e.max CAD material, a glass-ceramic used for making dental restorations such as full or partial crowns. The samples were machined into square chips .32 cm × .32 cm × .089 cm and annealed in the same furnace used by the dentist. The samples were exposed to a Cs-137 source using a PMMA source holder and then read in a Harshaw 3500 TLD reader. The samples were read without nitrogen gas flux using heating rates of 5 degrees C/s or 10 degrees C/s up to a maximum temperature of 400 degrees Celsius. The glow curves were analyzed using Systat PeakFIT peak-fitting software and Microsoft Excel spreadsheets. The authors gratefully thank Dr. Aaron Imdieke and the staff of River City Dental, St. Cloud, MN for the dental restoration materials and the use of their dental furnace. A sample subjected to a radiation exposure of .04 C/kg exhibits a glow curve with a prominent peak at approximately 140 degrees Celsius, which is well-modeled by the first order glow curve deconvolution formula developed by Kitis, Gomez-Ros, and Tuyn. The activation energy corresponding to this peak is approximately 1 eV. The thermoluminescent signal fades with time after exposure. Ivoclar Vivadent e.max CAD dental restoration material has the potential to be used as a material for retrospective Cs-137 radiation dosimetry. Future work could look at its thermoluminescent dosimetry properties in more detail and also at other dental restoration materials. The authors would like to thank Dr. Aaron Imdieke and the staff of River City Dental, St. Cloud, MN, for the donation of scrap dental restoration materials and the use of their dental furnace.
Author Gustafson, B
Barry, K
Ratliff, S
Author_xml – sequence: 1
  givenname: S
  surname: Ratliff
  fullname: Ratliff, S
  organization: Saint Cloud State University, St. Cloud, MN
– sequence: 2
  givenname: B
  surname: Gustafson
  fullname: Gustafson, B
  organization: Saint Cloud State University, St. Cloud, MN
– sequence: 3
  givenname: K
  surname: Barry
  fullname: Barry, K
  organization: Saint Cloud State University, St. Cloud, MN
BackLink https://www.ncbi.nlm.nih.gov/pubmed/28517144$$D View this record in MEDLINE/PubMed
BookMark eNo1j8tOwzAURC0Eog9Y8APIP-Di61cSdigtD6kIqbQLVtWNY4ugJq7ssGi_nqLAakZnRiPNhJx3oXOE3ACfAUB-BzOVSQ3KnJGxOFmmBC9GZJLSF-fcSM0vyUjkGjJQakw-3jdswdYsL-5p-YkRbe9ic8S-CR0Nns5d1-OOrlzqQxzoK_5WTtCHSMvEQGZ0hXUzpPOQmtb18XBFLjzukrv-0ynZPC7W5TNbvj29lA9LZoWUhqHhWldYKem4rW3t0WgsBGZKa65z46STYIUGLgtllBYGOOgKvMisx0qIKbkddvffVevq7T42LcbD9v-j-AGf-U-8
ContentType Journal Article
Copyright 2012 American Association of Physicists in Medicine.
Copyright_xml – notice: 2012 American Association of Physicists in Medicine.
DBID NPM
DOI 10.1118/1.4735146
DatabaseName PubMed
DatabaseTitle PubMed
DatabaseTitleList PubMed
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
Physics
EISSN 2473-4209
ExternalDocumentID 28517144
Genre Journal Article
GroupedDBID ---
--Z
-DZ
.GJ
0R~
1OB
1OC
29M
2WC
33P
36B
3O-
4.4
476
53G
5GY
5RE
5VS
AAHHS
AANLZ
AAQQT
AASGY
AAXRX
AAZKR
ABCUV
ABEFU
ABFTF
ABJNI
ABLJU
ABQWH
ABTAH
ABXGK
ACAHQ
ACBEA
ACCFJ
ACCZN
ACGFO
ACGFS
ACGOF
ACPOU
ACXBN
ACXQS
ADBBV
ADBTR
ADKYN
ADOZA
ADXAS
ADZMN
AEEZP
AEGXH
AEIGN
AENEX
AEQDE
AEUYR
AFBPY
AFFPM
AHBTC
AIACR
AIAGR
AITYG
AIURR
AIWBW
AJBDE
ALMA_UNASSIGNED_HOLDINGS
ALUQN
AMYDB
ASPBG
BFHJK
C45
CS3
DCZOG
DRFUL
DRMAN
DRSTM
DU5
EBD
EBS
EJD
EMB
EMOBN
F5P
G8K
HDBZQ
HGLYW
I-F
KBYEO
LATKE
LEEKS
LOXES
LUTES
LYRES
MEWTI
NPM
O9-
OVD
P2P
P2W
PALCI
PHY
RJQFR
RNS
ROL
SAMSI
SUPJJ
SV3
TEORI
TN5
TWZ
USG
WOHZO
WXSBR
XJT
ZGI
ZVN
ZXP
ZY4
ZZTAW
ID FETCH-LOGICAL-c2336-a6055bab43e0cdcdfa65a92a74550586e3e31c2510394645261015b1f27cfab22
IngestDate Sat Sep 28 07:59:31 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 6Part11
Keywords Annealing
Deconvolution
Thermoluminescent dosimeters
Furnaces
Materials properties
Dosimetry
Rivers
Activation energies
Thermoluminescence
Language English
License 2012 American Association of Physicists in Medicine.
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c2336-a6055bab43e0cdcdfa65a92a74550586e3e31c2510394645261015b1f27cfab22
PMID 28517144
ParticipantIDs pubmed_primary_28517144
PublicationCentury 2000
PublicationDate June 2012
PublicationDateYYYYMMDD 2012-06-01
PublicationDate_xml – month: 06
  year: 2012
  text: June 2012
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Medical physics (Lancaster)
PublicationTitleAlternate Med Phys
PublicationYear 2012
SSID ssj0006350
Score 2.0658636
Snippet The purpose of this work is to characterize the radiation-induced thermoluminescence properties of a dental restoration material and to see if the material...
SourceID pubmed
SourceType Index Database
StartPage 3723
Title SU-E-T-89: Characterization of Dental Restoration Material for Cs-137 Radiation Dosimetry
URI https://www.ncbi.nlm.nih.gov/pubmed/28517144
Volume 39
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LSwMxEA4-ULyI1veLHLxJaje7m931pq0PBKXUFvRUkjQLgm3F7qm_3slj41pU1MtSkraEfF9mJ5OZLwgdSx5EOeOMcCAHiRQTRMCbmijJMi5kLAQ32Rb37KYX3T7GlYN2U11SiLqcfllX8h9UoQ1w1VWyf0DW_yk0wGfAF56AMDx_hfFDj1ySLkkzva9veunlqXcDW7bYsWOuj7Gtd7wwQzP5hc0JCcLkpKMFCkxvazx5Hqric510eZhjoyAmTKtLp7m91MNHEjq8eHEij97DvNb1Wbmr6vKnOxf87a2SLuCCDjp7o0yOqitjnGiUhCSijaxqSa0skWMMa8O8OENqjWOY2NLiL6y2rkQI6voaZBeRrKD3OjTwUfANk8CKRf7cOyOgXXbNo_kk1abwXgd03Msa_K2GE5yCUZz6MWiRaPe7mQ2HcTy6a2jV7RjwuYV_Hc2pUQ0t37mciBpaaltYNtCT58MZnmUDHufYsgFX2IBLNmBgA7ZswJ4N2LNhE_WuLrvNG-KuziCShiGsPNilxoKLKFQNOZCDnLOYZ5Qnuog9TpnSsW9JtZxiZs62wYsOYhHkNJE5F5RuoYXReKR2EKawarMs1sKz8MVBQ9BIKcazJI1hq5nmu2jbTk__1eqj9MuJ2_u2Zx-tfLDqAC3msCDVIXh3hTgy-LwDBz5Jig
link.rule.ids 783
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=SU-E-T-89%3A+Characterization+of+Dental+Restoration+Material+for+Cs-137+Radiation+Dosimetry&rft.jtitle=Medical+physics+%28Lancaster%29&rft.au=Ratliff%2C+S&rft.au=Gustafson%2C+B&rft.au=Barry%2C+K&rft.date=2012-06-01&rft.eissn=2473-4209&rft.volume=39&rft.issue=6Part11&rft.spage=3723&rft_id=info:doi/10.1118%2F1.4735146&rft_id=info%3Apmid%2F28517144&rft_id=info%3Apmid%2F28517144&rft.externalDocID=28517144