HARMONIZING THREE-PHASE AC GRIDS A DUAL APPROACH COMPARISON OF PV-BATTERY ENERGY STORAGE SAPF CONTROLS
This paper investigates the effectiveness of two control approaches, Photovoltaic (PV)-Battery Energy Storage Systems (BESS) and SAPF, in harmonizing three-phase AC grids, focusing on power quality (PQ) and dq transformation theory. With the rising integration of renewable energy sources (RES), such...
Saved in:
Published in | Journal of mechanics of continua and mathematical sciences Vol. 20; no. 6; pp. 28 - 50 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Institute of Mechanics of Continua and Mathematical Sciences
01.06.2025
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | This paper investigates the effectiveness of two control approaches, Photovoltaic (PV)-Battery Energy Storage Systems (BESS) and SAPF, in harmonizing three-phase AC grids, focusing on power quality (PQ) and dq transformation theory. With the rising integration of renewable energy sources (RES), such as PV systems, ensuring PQ becomes critical. The dual approach comparison aims to assess the performance and suitability of these control strategies. The PV-BESS system utilizes batteries to store excess PV-generated energy, offering grid flexibility and improving stability. Conversely, SAPF controls utilize power electronics to address harmonics and reactive power fluctuations, thereby enhancing grid reliability. Through simulation and analysis, this study evaluates the efficacy, cost-effectiveness, and practicality of both approaches in PQ improvement using dq theory. The findings contribute to advancing grid integration techniques, optimizing renewable energy utilization, and ensuring a robust and stable power supply infrastructure, guided by PQ and dq transformation theory principles. |
---|---|
AbstractList | This paper investigates the effectiveness of two control approaches, Photovoltaic (PV)-Battery Energy Storage Systems (BESS) and SAPF, in harmonizing three-phase AC grids, focusing on power quality (PQ) and dq transformation theory. With the rising integration of renewable energy sources (RES), such as PV systems, ensuring PQ becomes critical. The dual approach comparison aims to assess the performance and suitability of these control strategies. The PV-BESS system utilizes batteries to store excess PV-generated energy, offering grid flexibility and improving stability. Conversely, SAPF controls utilize power electronics to address harmonics and reactive power fluctuations, thereby enhancing grid reliability. Through simulation and analysis, this study evaluates the efficacy, cost-effectiveness, and practicality of both approaches in PQ improvement using dq theory. The findings contribute to advancing grid integration techniques, optimizing renewable energy utilization, and ensuring a robust and stable power supply infrastructure, guided by PQ and dq transformation theory principles. |
Author | Arif, Mohammad Kumar C, Venkatesh Perumal, Maniraj Prasad Behera, Maheswar Sahu, Manoj Kumar Anitha, E. Baby Tripathy, Omkar Parida, Sritam |
Author_xml | – sequence: 1 givenname: Omkar surname: Tripathy fullname: Tripathy, Omkar – sequence: 2 givenname: Sritam surname: Parida fullname: Parida, Sritam – sequence: 3 givenname: Maheswar surname: Prasad Behera fullname: Prasad Behera, Maheswar – sequence: 4 givenname: Manoj Kumar surname: Sahu fullname: Sahu, Manoj Kumar – sequence: 5 givenname: E. Baby surname: Anitha fullname: Anitha, E. Baby – sequence: 6 givenname: Maniraj surname: Perumal fullname: Perumal, Maniraj – sequence: 7 givenname: Mohammad surname: Arif fullname: Arif, Mohammad – sequence: 8 givenname: Venkatesh surname: Kumar C fullname: Kumar C, Venkatesh |
BookMark | eNo9kN1KwzAYhoNMcOruwIPcQGf-miaHsevawmxLWoV5EtI0lQ1npfXEu3c_4nfywsfLw8tzC2afw6cH4AGjJeGRII_7gztMS4JIuER8iY5Hr8CcsJAFEZZoBuZIRjQQMgpvwGKa9qcGxZRjNgd9pvRzWeRveZHCJtNJElSZqhOoYpjqfFVDBVcvagNVVelSxRmMy-dK6bwuC1iuYfUaPKmmSfQWJkWi0y2sm1KrNIG1qtbHctHoclPfg-vefkx-8Zd3oFknTZwFmzLNY7UJHCGSBr1jHPe2C1HLiefEIt53rj_O9cgiJgjqUecwtU54LqxlHeI0ktQ7aUNi6R3IL9husHvzNe4Odvwxg92Z82MY340dv3fuw5uu87Z1FBPZCSZJK7HzgmIWiVbwlokji11YbhymafT9Pw8jczZvzubNybxB3JzN018pbXDD |
ContentType | Journal Article |
DBID | AAYXX CITATION DOA |
DOI | 10.26782/jmcms.2025.06.00003 |
DatabaseName | CrossRef DOAJ Directory of Open Access Journals |
DatabaseTitle | CrossRef |
DatabaseTitleList | CrossRef |
Database_xml | – sequence: 1 dbid: DOA name: DOAJ Open Access Full Text url: https://www.doaj.org/ sourceTypes: Open Website |
DeliveryMethod | fulltext_linktorsrc |
EISSN | 2454-7190 |
EndPage | 50 |
ExternalDocumentID | oai_doaj_org_article_ddeabc3129d8492b91ce831478b86b48 10_26782_jmcms_2025_06_00003 |
GroupedDBID | AAYXX ALMA_UNASSIGNED_HOLDINGS CITATION GROUPED_DOAJ |
ID | FETCH-LOGICAL-c2293-fc461fad50b62e62a06fdcf033e0a04820f0dc13ac8e68aa4d063793ec9a52a3 |
IEDL.DBID | DOA |
ISSN | 0973-8975 |
IngestDate | Wed Aug 27 01:24:28 EDT 2025 Thu Jul 03 08:41:12 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 6 |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c2293-fc461fad50b62e62a06fdcf033e0a04820f0dc13ac8e68aa4d063793ec9a52a3 |
OpenAccessLink | https://doaj.org/article/ddeabc3129d8492b91ce831478b86b48 |
PageCount | 23 |
ParticipantIDs | doaj_primary_oai_doaj_org_article_ddeabc3129d8492b91ce831478b86b48 crossref_primary_10_26782_jmcms_2025_06_00003 |
PublicationCentury | 2000 |
PublicationDate | 2025-06-01 |
PublicationDateYYYYMMDD | 2025-06-01 |
PublicationDate_xml | – month: 06 year: 2025 text: 2025-06-01 day: 01 |
PublicationDecade | 2020 |
PublicationTitle | Journal of mechanics of continua and mathematical sciences |
PublicationYear | 2025 |
Publisher | Institute of Mechanics of Continua and Mathematical Sciences |
Publisher_xml | – name: Institute of Mechanics of Continua and Mathematical Sciences |
SSID | ssj0003313614 |
Score | 2.2931056 |
Snippet | This paper investigates the effectiveness of two control approaches, Photovoltaic (PV)-Battery Energy Storage Systems (BESS) and SAPF, in harmonizing... |
SourceID | doaj crossref |
SourceType | Open Website Index Database |
StartPage | 28 |
SubjectTerms | bess power quality pq and dq theory shunt active power filters (sapf) |
Title | HARMONIZING THREE-PHASE AC GRIDS A DUAL APPROACH COMPARISON OF PV-BATTERY ENERGY STORAGE SAPF CONTROLS |
URI | https://doaj.org/article/ddeabc3129d8492b91ce831478b86b48 |
Volume | 20 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1NT-MwELVWnPaCQCziWz7s1SKxHcc5uiVtumqbKAkr4BI5jn1AoiAE_5-xU1D3xGWv0Thynj3zZpTxM0K_HdOapU4SmwVRbcaJTExCNAd2cDo2UfiDv1qL4pb_uUvudq768j1hozzwCNw1uJ_uDQNaGiTPaJ_FxkoW81T2UvQ8HPMFztsppnwMZixmYhT2zlJGZJYm47k5CsGZXj8-mSev1U2TIN7pB_zDSzvy_YFnZgdof5sgYjVO7BD9sJsj5ApVQ_BbPCzWc9wWdZ6TqlBNjtUUz-vFTYMVvrlVS6yqqi7VtMDTclWpetGUa1zOcPWXTFQLmes99q1q83vctGWt5jluVDUD43Vbl8vmF2pneTstyPaGBGIo8DRxhovY6SGJekGtoDoSbjAOPt9GGnyTRi4aTMy0kVZIrfkAGQl4pDWZTqhmx2hv87yxJwhTk0kW9RQsIm5prGUPYxMOFaGlqUhPEfmEp3sZdTA6qB8CnF2As_NwdqFLDuA8RROP4ZetV7EOD2Btu-3adt-t7dn_eMk5-ulnNrZ3XaC9t9d3ewmJxFt_FfbMB5JTuYY |
linkProvider | Directory of Open Access Journals |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=HARMONIZING+THREE-PHASE+AC+GRIDS+A+DUAL+APPROACH+COMPARISON+OF+PV-BATTERY+ENERGY+STORAGE+SAPF+CONTROLS&rft.jtitle=Journal+of+mechanics+of+continua+and+mathematical+sciences&rft.au=Omkar+Tripathy&rft.au=Sritam+Parida&rft.au=Maheswar+Prasad+Behera&rft.au=Manoj+Kumar+Sahu&rft.date=2025-06-01&rft.pub=Institute+of+Mechanics+of+Continua+and+Mathematical+Sciences&rft.issn=0973-8975&rft.eissn=2454-7190&rft.volume=20&rft.issue=6&rft.spage=28&rft.epage=50&rft_id=info:doi/10.26782%2Fjmcms.2025.06.00003&rft.externalDBID=DOA&rft.externalDocID=oai_doaj_org_article_ddeabc3129d8492b91ce831478b86b48 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0973-8975&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0973-8975&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0973-8975&client=summon |