Analytical modelling and analysis of magnet eddy current loss in magnet‐surrounded permanent magnet synchronous machine caused by stator slot effect
To improve the machine torque density, this paper proposes a magnet‐surrounded permanent magnet synchronous machine (MSPMSM). As the critical material of MSPMSM, the permanent magnet (PM) will produce significant eddy current loss under the action of eddy current electromotive force. Therefore, it i...
Saved in:
Published in | IET electric power applications Vol. 19; no. 1 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
01.01.2025
|
Online Access | Get full text |
Cover
Loading…
Abstract | To improve the machine torque density, this paper proposes a magnet‐surrounded permanent magnet synchronous machine (MSPMSM). As the critical material of MSPMSM, the permanent magnet (PM) will produce significant eddy current loss under the action of eddy current electromotive force. Therefore, it is essential to investigate the change in PM eddy current loss and methods to suppress it. To solve the above problems, a simplified analytical calculation model for the eddy current loss of PMs caused by stator slotting is proposed. The distribution law of eddy current loss of PMs caused by stator slotting is studied. The concept of influence depth is proposed to solve the problem of unclear correspondence between the groove depth on the PM surface and the eddy current loss of PMs. The calculation results of the influence depth are used to guide the single‐side partial grooving method to reduce the eddy current loss of PMs. In addition, a comparative analysis is conducted on the anti‐demagnetisation ability of PMs before and after MSPMSM optimisation. Finally, the experiment verifies the correctness of the analytical calculation and the high torque density of the MSPMSM. |
---|---|
AbstractList | To improve the machine torque density, this paper proposes a magnet‐surrounded permanent magnet synchronous machine (MSPMSM). As the critical material of MSPMSM, the permanent magnet (PM) will produce significant eddy current loss under the action of eddy current electromotive force. Therefore, it is essential to investigate the change in PM eddy current loss and methods to suppress it. To solve the above problems, a simplified analytical calculation model for the eddy current loss of PMs caused by stator slotting is proposed. The distribution law of eddy current loss of PMs caused by stator slotting is studied. The concept of influence depth is proposed to solve the problem of unclear correspondence between the groove depth on the PM surface and the eddy current loss of PMs. The calculation results of the influence depth are used to guide the single‐side partial grooving method to reduce the eddy current loss of PMs. In addition, a comparative analysis is conducted on the anti‐demagnetisation ability of PMs before and after MSPMSM optimisation. Finally, the experiment verifies the correctness of the analytical calculation and the high torque density of the MSPMSM. |
Author | Song, Zhanfeng Long, Yuhang |
Author_xml | – sequence: 1 givenname: Yuhang orcidid: 0009-0000-7706-7527 surname: Long fullname: Long, Yuhang organization: School of Electrical and Information Engineering Tianjin University Tianjin China – sequence: 2 givenname: Zhanfeng surname: Song fullname: Song, Zhanfeng organization: School of Electrical and Information Engineering Tianjin University Tianjin China |
BookMark | eNo9UMtOwzAQtFCRaAsXvsBnpBTbedg5VhVQpEpc4Bw59roNcuzKTg658Qmc-EC-BBcqDqtd7czOamaBZs47QOiWkhUlRX0P9shWlJWMX6A55SXNRMXr2f9ckSu0iPGdkLKsimqOvtZO2mnolLS49xqs7dweS6dTJSB2EXuDe7l3MGDQesJqDAHcgK2PEXfujH1_fMYE-NFp0PgIoZfuxDpfxsmpQ_DOjzGt1KFzgJUcY-K2E46DHHzA0fr0wxhQwzW6NNJGuDn3JXp7fHjdbLPdy9PzZr3LFGPVkFXa5ARyLkXNeMWIzrWidW3KwtDW8JoWwggKgrfJrRaaS0Pz1hgBULBW5fkS3f3pqpDsBDDNMXS9DFNDSXNKtDkl2vwmmv8AteBxEQ |
Cites_doi | 10.1109/tmag.2013.2285525 10.1109/20.195557 10.1109/tia.2018.2874350 10.1109/tmag.2018.2882514 10.1049/iet-epa.2017.0863 10.1049/iet‐epa.2011.0385 10.1049/elp2.12386 10.1109/tmag.2011.2165321 10.1049/iet‐epa.2018.0083 10.1109/tia.2017.2683440 10.1080/03616968108960089 10.1109/tie.2022.3229395 10.1109/tec.2020.2966674 10.1109/tmag.2011.2155042 10.1109/tia.2017.2693178 10.1109/tmag.2015.2500878 10.1109/tmag.2019.2895887 10.1109/tec.2021.3137803 10.1049/iet‐epa.2016.0778 10.1109/tec.2023.3260109 10.1109/tie.2019.2908594 10.1109/tmag.2017.2760928 10.1109/20.195559 10.1049/elp2.12131 10.1109/tmag.2012.2203607 |
ContentType | Journal Article |
DBID | AAYXX CITATION |
DOI | 10.1049/elp2.12527 |
DatabaseName | CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | CrossRef |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISSN | 1751-8679 |
ExternalDocumentID | 10_1049_elp2_12527 |
GroupedDBID | .DC 0R~ 0ZK 1OC 24P 29I 2QL 4.4 4IJ 5GY 6IK 6OB 8FE 8FG 8VB 96U AAHJG AAJGR AAMMB AAYXX ABJCF ABQXS ACCMX ACESK ACGFO ACGFS ACIWK ACXQS ADEYR AEFGJ AEGXH AENEX AFAZI AFKRA AGXDD AIDQK AIDYY ALMA_UNASSIGNED_HOLDINGS ALUQN ARAPS AVUZU BENPR BGLVJ CCPQU CITATION CS3 DU5 EBS EJD F8P GOZPB GROUPED_DOAJ GRPMH HCIFZ HZ~ IAO IDLOA IGS IPLJI ITC K1G L6V LAI M43 M7S MCNEO MS~ O9- OK1 P62 PHGZM PHGZT PQGLB PTHSS QWB RNS RUI S0W U5U UNMZH WIN ZL0 ~ZZ |
ID | FETCH-LOGICAL-c226t-6df30e37a8927620d3dc199f54f1bf79148f81e87b564d8d7af13bff8ee42bc33 |
ISSN | 1751-8660 |
IngestDate | Tue Aug 05 11:59:22 EDT 2025 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c226t-6df30e37a8927620d3dc199f54f1bf79148f81e87b564d8d7af13bff8ee42bc33 |
ORCID | 0009-0000-7706-7527 |
OpenAccessLink | https://ietresearch.onlinelibrary.wiley.com/doi/pdf/10.1049/elp2.12527 |
ParticipantIDs | crossref_primary_10_1049_elp2_12527 |
PublicationCentury | 2000 |
PublicationDate | 2025-01-01 |
PublicationDateYYYYMMDD | 2025-01-01 |
PublicationDate_xml | – month: 01 year: 2025 text: 2025-01-01 day: 01 |
PublicationDecade | 2020 |
PublicationTitle | IET electric power applications |
PublicationYear | 2025 |
References | e_1_2_12_4_1 e_1_2_12_3_1 e_1_2_12_6_1 e_1_2_12_5_1 e_1_2_12_19_1 e_1_2_12_18_1 e_1_2_12_2_1 e_1_2_12_17_1 e_1_2_12_16_1 e_1_2_12_20_1 e_1_2_12_21_1 Heller B. (e_1_2_12_24_1) 1977 e_1_2_12_22_1 e_1_2_12_23_1 e_1_2_12_25_1 e_1_2_12_26_1 e_1_2_12_27_1 e_1_2_12_15_1 e_1_2_12_14_1 e_1_2_12_13_1 e_1_2_12_12_1 e_1_2_12_8_1 e_1_2_12_11_1 e_1_2_12_7_1 e_1_2_12_10_1 e_1_2_12_9_1 |
References_xml | – ident: e_1_2_12_7_1 doi: 10.1109/tmag.2013.2285525 – ident: e_1_2_12_18_1 doi: 10.1109/20.195557 – ident: e_1_2_12_20_1 doi: 10.1109/tia.2018.2874350 – ident: e_1_2_12_9_1 doi: 10.1109/tmag.2018.2882514 – ident: e_1_2_12_10_1 doi: 10.1049/iet-epa.2017.0863 – ident: e_1_2_12_8_1 doi: 10.1049/iet‐epa.2011.0385 – ident: e_1_2_12_11_1 doi: 10.1049/elp2.12386 – volume-title: Harmonic Field Effects in Induction Machines year: 1977 ident: e_1_2_12_24_1 – ident: e_1_2_12_25_1 doi: 10.1109/tmag.2011.2165321 – ident: e_1_2_12_5_1 doi: 10.1049/iet‐epa.2018.0083 – ident: e_1_2_12_3_1 doi: 10.1109/tia.2017.2683440 – ident: e_1_2_12_17_1 doi: 10.1080/03616968108960089 – ident: e_1_2_12_12_1 doi: 10.1109/tie.2022.3229395 – ident: e_1_2_12_22_1 doi: 10.1109/tec.2020.2966674 – ident: e_1_2_12_6_1 doi: 10.1109/tmag.2011.2155042 – ident: e_1_2_12_15_1 doi: 10.1109/tia.2017.2693178 – ident: e_1_2_12_16_1 doi: 10.1109/tmag.2015.2500878 – ident: e_1_2_12_23_1 doi: 10.1109/tmag.2019.2895887 – ident: e_1_2_12_2_1 doi: 10.1109/tec.2021.3137803 – ident: e_1_2_12_21_1 doi: 10.1049/iet‐epa.2016.0778 – ident: e_1_2_12_13_1 doi: 10.1109/tec.2023.3260109 – ident: e_1_2_12_26_1 doi: 10.1109/tie.2019.2908594 – ident: e_1_2_12_27_1 doi: 10.1109/tmag.2017.2760928 – ident: e_1_2_12_19_1 doi: 10.1109/20.195559 – ident: e_1_2_12_4_1 doi: 10.1049/elp2.12131 – ident: e_1_2_12_14_1 doi: 10.1109/tmag.2012.2203607 |
SSID | ssj0055646 |
Score | 2.4174166 |
Snippet | To improve the machine torque density, this paper proposes a magnet‐surrounded permanent magnet synchronous machine (MSPMSM). As the critical material of... |
SourceID | crossref |
SourceType | Index Database |
Title | Analytical modelling and analysis of magnet eddy current loss in magnet‐surrounded permanent magnet synchronous machine caused by stator slot effect |
Volume | 19 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9NAEF6FcoFDVV7iUdBIcLMcYu_aXh8RKipIIA6pVE5R9oUqpU7UOIf01J_AiR_IL2HGu3aWlkPhYkWz3iTy92lmdjwPxt4YMdG64lnKrVWp0EKkqi4UOnKFsRNlSt7NWPr8pTw-EZ9Oi9PR6DKuLmnVWF_-ta7kf1BFGeJKVbL_gOzwpSjAz4gvXhFhvN4K466jiA9GdxNtFn3F4TxqNXI-_97YNrHGbBMdujEt0DRSpMOvDQkPa1ymMUvohK5IYzd0b9i_3jaaGulSyux5l4FJGWObtfdgqS5peZGsF8s2pIjEXu_Ho2ni5-2c6WRFc9mS-MX5kBQU0oO_bSiKPcR-gpRC284GeYhT5EUUp_CqtSqyVJZ-esDYxjI_TmbQx_V13t1Q83isIcAXq3yMDppvLvBnL-1rNm7IPOzeuYt6Rntn3d477G6ORwzSkbn42lvxoih9ZVr_r_vWtqJ-u_vdyJmJvJLpAdsPxwl457nxgI1s85Ddj5pMPmI_dyyBgSWALIGeJbB04FEGYgkElgCxBM6asPbr6seOHzDwo98Z8QMCP8DzA9QWPD-A-AGeH4_ZyYej6fvjNEzjSDW66G1aGscnlldzWedoQSeGG53VtSuEy5SrajxXO5lZWSl8dEaaau4yrpyT1opcac6fsL1m2dinDEzlbKlLVaMFENpVEnWCkk6JzEmnLX_GXvePdbbyTVdmN4F7fqu7XrB7OzYesr32YmNfoh_Zqlcd4L8B4Sx_Ew |
linkProvider | Wiley-Blackwell |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Analytical+modelling+and+analysis+of+magnet+eddy+current+loss+in+magnet%E2%80%90surrounded+permanent+magnet+synchronous+machine+caused+by+stator+slot+effect&rft.jtitle=IET+electric+power+applications&rft.au=Long%2C+Yuhang&rft.au=Song%2C+Zhanfeng&rft.date=2025-01-01&rft.issn=1751-8660&rft.eissn=1751-8679&rft.volume=19&rft.issue=1&rft_id=info:doi/10.1049%2Felp2.12527&rft.externalDBID=n%2Fa&rft.externalDocID=10_1049_elp2_12527 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1751-8660&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1751-8660&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1751-8660&client=summon |