Phased array ultrasonic testing (PAUT) performed on electroslag weld specimen subject to cyclical tension load testing

Following the discovery of discontinuities in a weld specimen, which was made with a process called narrow gap electroslag welding (ESW-NG), the specimen was subject to mechanical cyclical tension loading until failure. The loading involved one block of 100 tension-only cycles at 42 ksi peak stress...

Full description

Saved in:
Bibliographic Details
Published inBridge structures Vol. 13; no. 4; pp. 135 - 146
Main Authors Wahbeh, M., Foerder, M., Boundouki, R.
Format Journal Article
LanguageEnglish
Published London, England SAGE Publications 02.04.2018
Subjects
Online AccessGet full text

Cover

Loading…
Abstract Following the discovery of discontinuities in a weld specimen, which was made with a process called narrow gap electroslag welding (ESW-NG), the specimen was subject to mechanical cyclical tension loading until failure. The loading involved one block of 100 tension-only cycles at 42 ksi peak stress followed by a second block of 20 tension-only cycles at 55 ksi stress. Phased Array Ultrasonic Testing (PAUT) was performed to understand whether or not the loading protocol has caused the internal discontinuities to increase in length. The PAUT was performed before cycling began and after the end of first block of cycles. Conventional Ultrasonic Testing was also performed in order to develop comparative baseline results. PAUT utilizes an aperture, which is composed of multiple individual small transducer elements which can be pulsed individually at a computer-calculated timing (“phased or delay laws”) producing a sound beam which is swept through a volume of material. Utilizing PAUT, the operator has the ability to “steer” and “focus” the beam electronically through the material being examined at multiple angles in one scan (for example 45° through 75°) in lieu of being fixed at a certain angle as in conventional Ultrasonic testing (UT). The PAUT equipment utilized has the capabilities of 16 active pulsars capable of multiplexing over 64 channels (16:64) displayed in A, B, C, S, Linear scans, or a combination thereof. Scanning with a digital encoder was utilized in order to collect the data for post processing, analysis and data documentation. This presentation will discuss the findings of the PAUT on this weld specimen. The PAUT aperture utilized was a 5L-60 with 1 mm pitch and Sectorial and Linear scans were utilized. The sectorial scan results of the PAUT before and after cycling showed an increase in dimensions of the recorded indications by an average of 6–8 mm or approximately 50% of the original dimensions. The presentation will also include a discussion of the advantages and limitations of PAUT for various bridge applications. The advantages of PAUT include speed, flexibility, and the ability to perform complex inspections.
AbstractList Following the discovery of discontinuities in a weld specimen, which was made with a process called narrow gap electroslag welding (ESW-NG), the specimen was subject to mechanical cyclical tension loading until failure. The loading involved one block of 100 tension-only cycles at 42 ksi peak stress followed by a second block of 20 tension-only cycles at 55 ksi stress. Phased Array Ultrasonic Testing (PAUT) was performed to understand whether or not the loading protocol has caused the internal discontinuities to increase in length. The PAUT was performed before cycling began and after the end of first block of cycles. Conventional Ultrasonic Testing was also performed in order to develop comparative baseline results. PAUT utilizes an aperture, which is composed of multiple individual small transducer elements which can be pulsed individually at a computer-calculated timing (“phased or delay laws”) producing a sound beam which is swept through a volume of material. Utilizing PAUT, the operator has the ability to “steer” and “focus” the beam electronically through the material being examined at multiple angles in one scan (for example 45° through 75°) in lieu of being fixed at a certain angle as in conventional Ultrasonic testing (UT). The PAUT equipment utilized has the capabilities of 16 active pulsars capable of multiplexing over 64 channels (16:64) displayed in A, B, C, S, Linear scans, or a combination thereof. Scanning with a digital encoder was utilized in order to collect the data for post processing, analysis and data documentation. This presentation will discuss the findings of the PAUT on this weld specimen. The PAUT aperture utilized was a 5L-60 with 1 mm pitch and Sectorial and Linear scans were utilized. The sectorial scan results of the PAUT before and after cycling showed an increase in dimensions of the recorded indications by an average of 6–8 mm or approximately 50% of the original dimensions. The presentation will also include a discussion of the advantages and limitations of PAUT for various bridge applications. The advantages of PAUT include speed, flexibility, and the ability to perform complex inspections.
Author Foerder, M.
Boundouki, R.
Wahbeh, M.
Author_xml – sequence: 1
  givenname: M.
  surname: Wahbeh
  fullname: Wahbeh, M.
  organization: , New York, NY
– sequence: 2
  givenname: M.
  surname: Foerder
  fullname: Foerder, M.
  organization: , New York, NY
– sequence: 3
  givenname: R.
  surname: Boundouki
  fullname: Boundouki, R.
  email: rboundouki@altavistasolutions.com
  organization: , New York, NY
BookMark eNptkFtPAjEQhRuDiYC--Av65iVZ7Y3t7iMSbwmJROF5M3RncUlpSbtg-PfWoG8-zSTzzck5Z0B6zjsk5JKzOymkvH94_8h4wbhQJ6TPtVJZUZZlL-0jLTOhCn1GBjGuGVNcilGf7GefELGmEAIc6M52AaJ3raEdxq51K3o9Gy_mN3SLofFhk0jvKFo0XfDRwop-oa1p3KJpN-ho3C3X6UY7T83B2NaATUoutunLeqj_ZM_JaQM24sXvHJLF0-N88pJN355fJ-NpZoQQXaY11wyZamCJZQ3lSNQCkeUoNZaYKyUM1IVRUKQ0Jq-LosmXiSlz0JLLRg7J7VHXJLsxYFNtQ7uBcKg4q34aq1Jj1bGxBF8d4QgrrNZ-F1zy9h_5DZxUbkk
ContentType Journal Article
Copyright 2017 – IOS Press and the authors. All rights reserved
Copyright_xml – notice: 2017 – IOS Press and the authors. All rights reserved
DBID AAYXX
CITATION
DOI 10.3233/BRS-180124
DatabaseName CrossRef
DatabaseTitle CrossRef
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISSN 1744-8999
EndPage 146
ExternalDocumentID 10_3233_BRS_180124
10.3233_BRS-180124
GroupedDBID .4S
.DC
0R~
23N
4.4
AAGLT
AAQXI
ABUJY
ACGEJ
ACPQW
ADMLS
ADXPE
ADZMO
AEGXH
AFRHK
AFYTF
AHDMH
AJNRN
ALMA_UNASSIGNED_HOLDINGS
ARCSS
ARTOV
CS3
DU5
EBS
EDO
EJD
H13
HF~
HZ~
I-F
IOS
J8X
MIO
MV1
NGNOM
O9-
SAUOL
SCNPE
SFC
TFW
TUS
TWF
TWQ
AAPII
AAYXX
AJGYC
CITATION
ID FETCH-LOGICAL-c222t-77170e04fabe9da952d2ee06e37e9e6442cad8c4a8132c6d88f6b2d296a7313f3
ISSN 1573-2487
IngestDate Tue Aug 05 12:04:44 EDT 2025
Tue Jun 17 22:27:26 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 4
Keywords Phased Array Ultrasonic Testing
Electroslag
Ultrasonic Testing
Non-Destructive Testing
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c222t-77170e04fabe9da952d2ee06e37e9e6442cad8c4a8132c6d88f6b2d296a7313f3
PageCount 12
ParticipantIDs crossref_primary_10_3233_BRS_180124
sage_journals_10_3233_BRS_180124
PublicationCentury 2000
PublicationDate 20180402
PublicationDateYYYYMMDD 2018-04-02
PublicationDate_xml – month: 4
  year: 2018
  text: 20180402
  day: 2
PublicationDecade 2010
PublicationPlace London, England
PublicationPlace_xml – name: London, England
PublicationTitle Bridge structures
PublicationYear 2018
Publisher SAGE Publications
Publisher_xml – name: SAGE Publications
References 1996; 59
10.3233/BRS-180124_ref1
References_xml – volume: 59
  issue: 3
  year: 1996
  article-title: Narrow-gap improved electroslag welding for bridges
  publication-title: FHWA Public Roads Magazine
– ident: 10.3233/BRS-180124_ref1
SSID ssj0041325
Score 2.057909
Snippet Following the discovery of discontinuities in a weld specimen, which was made with a process called narrow gap electroslag welding (ESW-NG), the specimen was...
SourceID crossref
sage
SourceType Index Database
Publisher
StartPage 135
Title Phased array ultrasonic testing (PAUT) performed on electroslag weld specimen subject to cyclical tension load testing
URI https://journals.sagepub.com/doi/full/10.3233/BRS-180124
Volume 13
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Ja9wwFBbTyaU9lK403RC0hxaj6UiWFx2TtiGUTglZaG5Gm5PDMA4eT0PSP98nSx57ykCXizHiyRh9n_UW672H0NvcCM41NSQBbU0454oo0HREK1oyXSomhctGnn1LD8_4l_PkfDT6OcwuadRE327NK_kfVGEMcHVZsv-A7PqhMAD3gC9cAWG4_hXGR5egg0wk61reRKt5U8tl29CmcaUzfAjgCF7Vef5XPkEApAHu0PsG2HARXdu5iVy-pSvzHy1XygVmnEWqb_S8RbA94w6z5pU03aM3_gX7nC9fiXZV94cSv8tLZduwzWzSaztbG0-TfnDf9XaqVr6D9vFkGImgeXuApfdb_S-wrcFGmmQxYTyoVuvHMs4JeHtiYy-OB5zjg42V-qImQUeHsOXv23_MXHj6YP_4hFCneXmv5NZHD4NY0QvdQTsMfAw2Rjt7n2ZfTzpFDuq97dm7fnlf3dbN_tDP3rBnBocBW_vk9AG6HxwLvOdZ8hCN7OIRujcoN_kY_fB8wS1fcM8XHEDF7xxb3uM1V3C1wAOuYMcV3HEFB67gpsIdV3DgCnZc6R77BJ0dfD79eEhC3w2iwVpswOGi2dROeSmVFUaKhBlm7TS1cWaFBQOaaWlyzWUOK6RTk-dlqkBGpDKLaVzGT9F4US3sM4RLKmjuBrPY8DIvBUtsaVJD06k1OpG76E23esWVL69SgFvaIVT4Nd5F2C1sET695RaR538WeYHu9qx9icbwVdhXYFE26nVA_hclt3d4
linkProvider EBSCOhost
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Phased+array+ultrasonic+testing+%28PAUT%29+performed+on+electroslag+weld+specimen+subject+to+cyclical+tension+load+testing&rft.jtitle=Bridge+structures&rft.au=Wahbeh%2C+M.&rft.au=Foerder%2C+M.&rft.au=Boundouki%2C+R.&rft.date=2018-04-02&rft.pub=SAGE+Publications&rft.issn=1573-2487&rft.eissn=1744-8999&rft.volume=13&rft.issue=4&rft.spage=135&rft.epage=146&rft_id=info:doi/10.3233%2FBRS-180124&rft.externalDocID=10.3233_BRS-180124
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1573-2487&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1573-2487&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1573-2487&client=summon