sEMG Feature Analysis on Forearm Muscle Fatigue During Isometric Contractions

In order to detect and assess the muscle fatigue state with the surface electromyography(sEMG) characteristic parameters,this paper carried out a series of isometric contraction experiments to induce the fatigue on the forearm muscles from four subjects,and recorded the sEMG signals of the flexor ca...

Full description

Saved in:
Bibliographic Details
Published inTransactions of Tianjin University Vol. 20; no. 2; pp. 139 - 143
Main Author 明东 王欣 徐瑞 邱爽 赵欣 綦宏志 周鹏 张力新 万柏坤
Format Journal Article
LanguageEnglish
Published Heidelberg Tianjin University 01.04.2014
Subjects
Online AccessGet full text

Cover

Loading…
Abstract In order to detect and assess the muscle fatigue state with the surface electromyography(sEMG) characteristic parameters,this paper carried out a series of isometric contraction experiments to induce the fatigue on the forearm muscles from four subjects,and recorded the sEMG signals of the flexor carpi ulnaris.sEMG’s median frequency(MDF) and mean frequency(MF) were extracted by short term Fourier transform(STFT),and the root mean square(RMS) of wavelet coefficients in the frequency band of 5—45 Hz was obtained by continuous wavelet transform(CWT).The results demonstrate that both MDF and MF show downward trends within 1 min; however,RMS shows an upward trend within the same time.The three parameters are closely correlated with absolute values of mean correlation coefficients greater than 0.8.It is suggested that the three parameters above can be used as reliable indicators to evaluate the level of muscle fatigue during isometric contractions.
AbstractList In order to detect and assess the muscle fatigue state with the surface electromyography (sEMG) characteristic parameters, this paper carried out a series of isometric contraction experiments to induce the fatigue on the forearm muscles from four subjects, and recorded the sEMG signals of the flexor carpi ulnaris. sEMG’s median frequency (MDF) and mean frequency (MF) were extracted by short term Fourier transform (STFT), and the root mean square (RMS) of wavelet coefficients in the frequency band of 5–45 Hz was obtained by continuous wavelet transform (CWT). The results demonstrate that both MDF and MF show downward trends within 1 min; however, RMS shows an upward trend within the same time. The three parameters are closely correlated with absolute values of mean correlation coefficients greater than 0.8. It is suggested that the three parameters above can be used as reliable indicators to evaluate the level of muscle fatigue during isometric contractions.
In order to detect and assess the muscle fatigue state with the surface electromyography (sEMG) character-istic parameters, this paper carried out a series of isometric contraction experiments to induce the fatigue on the fore-arm muscles from four subjects, and recorded the sEMG signals of the flexor carpi ulnaris. sEMG's median frequency (MDF) and mean frequency (MF) were extracted by short term Fourier transform (STFT), and the root mean square (RMS) of wavelet coefficients in the frequency band of 5-45 Hz was obtained by continuous wavelet transform (CWT). The results demonstrate that both MDF and MF show downward trends within 1 min;however, RMS shows an upward trend within the same time. The three parameters are closely correlated with absolute values of mean corre-lation coefficients greater than 0.8. It is suggested that the three parameters above can be used as reliable indicators to evaluate the level of muscle fatigue during isometric contractions.
In order to detect and assess the muscle fatigue state with the surface electromyography(sEMG) characteristic parameters,this paper carried out a series of isometric contraction experiments to induce the fatigue on the forearm muscles from four subjects,and recorded the sEMG signals of the flexor carpi ulnaris.sEMG’s median frequency(MDF) and mean frequency(MF) were extracted by short term Fourier transform(STFT),and the root mean square(RMS) of wavelet coefficients in the frequency band of 5—45 Hz was obtained by continuous wavelet transform(CWT).The results demonstrate that both MDF and MF show downward trends within 1 min; however,RMS shows an upward trend within the same time.The three parameters are closely correlated with absolute values of mean correlation coefficients greater than 0.8.It is suggested that the three parameters above can be used as reliable indicators to evaluate the level of muscle fatigue during isometric contractions.
Author 明东 王欣 徐瑞 邱爽 赵欣 綦宏志 周鹏 张力新 万柏坤
AuthorAffiliation Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, School of Precision Instrument and Opto- Electronics Engineering, Tianjin University, Tianjin 300072, China
Author_xml – sequence: 1
  fullname: 明东 王欣 徐瑞 邱爽 赵欣 綦宏志 周鹏 张力新 万柏坤
BookMark eNp9kEFPAjEQhRuDiYD-AG_17upMt-zSI0EWSSBe9Nx0t11cAi22uxH-vSUQvXmZmcN88968AelZZw0h9whPCJA_B2QMRALIE4ZjTNgV6aMQo2SMIuvFGSBLuBizGzIIYQPABeTYJ6swW81pYVTbeUMnVm2PoQnUWVo4b5Tf0VUXqq2hhWqbdWfoS-cbu6aL4Ham9U1Fp862XlVt42y4Jde12gZzd-lD8lHM3qevyfJtvphOlkkVzUGic6ZHLCvrDE0uUGiFFdM58kyA1qnhKOq8TJmC2MZVzUuFGjSUjOuRyXk6JI_nu9_K1squ5cZ1PnoPsm2U3ejDoZSGxTAgFojreF6vvAvBm1rufbNT_igR5Ck-eY5PRkKe4pMsMuzMhP3pYeP_NP6DHi5Cn86uvyL3q8QFZjmkPP0B-W9_NQ
Cites_doi 10.1016/j.jelekin.2007.07.003
10.1016/j.clinbiomech.2009.01.010
10.1007/s12209-009-0053-y
10.1016/j.jelekin.2008.09.007
10.1016/S1050-6411(98)00042-X
10.1113/jphysiol.2007.139477
10.1016/j.jelekin.2004.08.007
10.1016/j.jelekin.2010.10.006
10.1016/j.jelekin.2012.08.004
10.1016/j.clinbiomech.2008.08.003
10.1007/s004210100455
10.1007/s12209-011-1628-y
10.1046/j.1365-201X.1997.00168.x
10.1002/9781444319620
ContentType Journal Article
Copyright Tianjin University and Springer-Verlag Berlin Heidelberg 2014
Copyright © Wanfang Data Co. Ltd. All Rights Reserved.
Copyright_xml – notice: Tianjin University and Springer-Verlag Berlin Heidelberg 2014
– notice: Copyright © Wanfang Data Co. Ltd. All Rights Reserved.
DBID 2RA
92L
CQIGP
~WA
AAYXX
CITATION
2B.
4A8
92I
93N
PSX
TCJ
DOI 10.1007/s12209-014-2181-2
DatabaseName 维普期刊资源整合服务平台
中文科技期刊数据库-CALIS站点
维普中文期刊数据库
中文科技期刊数据库- 镜像站点
CrossRef
Wanfang Data Journals - Hong Kong
WANFANG Data Centre
Wanfang Data Journals
万方数据期刊 - 香港版
China Online Journals (COJ)
China Online Journals (COJ)
DatabaseTitle CrossRef
DatabaseTitleList


DeliveryMethod fulltext_linktorsrc
Discipline Sciences (General)
Engineering
DocumentTitleAlternate sEMG Feature Analysis on Forearm Muscle Fatigue During Isometric Contractions
EISSN 1995-8196
EndPage 143
ExternalDocumentID tianjdxxb_e201402010
10_1007_s12209_014_2181_2
49167034
GrantInformation_xml – fundername: the National Natural Science Foundation of China; the National Key Technology R&D Program of the Ministry of Science and Technology of China
  funderid: (81222021 and 31011130042); (2012BAI34B02)
GroupedDBID -03
-0C
-5B
-5G
-BR
-EM
-SC
-S~
-Y2
-~C
.86
.VR
06D
0R~
0VY
123
1N0
29Q
29~
2B.
2C-
2J2
2JN
2JY
2KG
2KM
2LR
2RA
2VQ
2~H
30V
4.4
406
408
40D
40E
5VR
5VS
6NX
8TC
92D
92I
92L
92M
93E
93N
95-
95.
95~
96X
9D9
9DC
AAAVM
AABHQ
AAFGU
AAHNG
AAHTB
AAIAL
AAJKR
AANZL
AARHV
AARTL
AATNV
AATVU
AAUYE
AAWCG
AAYFA
AAYIU
AAYQN
AAYTO
ABDZT
ABECU
ABFGW
ABFTV
ABHQN
ABJNI
ABJOX
ABKAS
ABKCH
ABMNI
ABMQK
ABNWP
ABPEJ
ABQBU
ABSXP
ABTEG
ABTHY
ABTKH
ABTMW
ABWNU
ABXPI
ACAOD
ACBMV
ACBRV
ACBXY
ACBYP
ACGFS
ACHSB
ACHXU
ACIGE
ACIPQ
ACIWK
ACKNC
ACMDZ
ACMLO
ACOKC
ACOMO
ACSNA
ACTTH
ACVWB
ACWMK
ACZOJ
ADHHG
ADHIR
ADINQ
ADKNI
ADKPE
ADMDM
ADOXG
ADRFC
ADTPH
ADURQ
ADYFF
ADZKW
AEBTG
AEFTE
AEGAL
AEGNC
AEJHL
AEJRE
AEOHA
AEPYU
AESKC
AESTI
AETLH
AEVLU
AEVTX
AEXYK
AFGCZ
AFLOW
AFNRJ
AFQWF
AFUIB
AFWTZ
AFZKB
AGAYW
AGDGC
AGGBP
AGJBK
AGMZJ
AGQMX
AGWIL
AGWZB
AGYKE
AHAVH
AHBYD
AHSBF
AHYZX
AIAKS
AIIXL
AILAN
AIMYW
AITGF
AJBLW
AJDOV
AJRNO
AJZVZ
AKQUC
ALMA_UNASSIGNED_HOLDINGS
ALWAN
AMKLP
AMXSW
AMYLF
AMYQR
AOCGG
ARMRJ
AXYYD
B-.
BA0
BDATZ
BGNMA
CAG
CAJEC
CAJUS
CCEZO
CEKLB
CHBEP
COF
CQIGP
CS3
CSCUP
CW9
DDRTE
DNIVK
DPUIP
EBLON
EBS
EIOEI
EJD
ESBYG
FA0
FERAY
FFXSO
FIGPU
FINBP
FNLPD
FRRFC
FSGXE
FWDCC
GGCAI
GGRSB
GJIRD
GNWQR
GQ6
GQ7
HF~
HG6
HLICF
HMJXF
HRMNR
HZ~
IJ-
IKXTQ
IWAJR
IXC
IXD
I~X
I~Z
J-C
JBSCW
JUIAU
JZLTJ
KOV
LLZTM
M4Y
MA-
NPVJJ
NQJWS
NU0
O9-
O9J
P9P
PF0
PT4
Q--
Q-2
QOS
R-C
R89
R9I
RIG
ROL
RPX
RSV
RT3
S16
S1Z
S27
S3B
SAP
SCL
SDH
SEG
SHX
SISQX
SNE
SNPRN
SNX
SOHCF
SOJ
SPISZ
SRMVM
SSLCW
STPWE
SZN
T13
T8S
TCJ
TGH
TSG
TSV
TUC
U1F
U1G
U2A
U5C
U5M
UG4
UNUBA
UOJIU
UTJUX
UZXMN
VC2
VFIZW
W48
WK8
YLTOR
Z7R
ZMTXR
~A9
~WA
AACDK
AAJBT
AASML
AAXDM
AAYZH
ABAKF
ACDTI
ACPIV
AEFQL
AEMSY
AFBBN
AGQEE
AIGIU
H13
SJYHP
AAPKM
AAYXX
ABBRH
ABDBE
ABFSG
ACSTC
AEZWR
AFDZB
AFHIU
AFOHR
AHPBZ
AHWEU
AIXLP
ATHPR
AYFIA
CITATION
4A8
PSX
ID FETCH-LOGICAL-c2180-d72d526bf61e7919da1c2d714690dd3e419f7b32a0f7b8cf4ba1d0d0b24d5e743
IEDL.DBID U2A
ISSN 1006-4982
IngestDate Thu May 29 04:11:18 EDT 2025
Tue Jul 01 02:15:54 EDT 2025
Fri Feb 21 02:33:39 EST 2025
Wed Feb 14 10:37:31 EST 2024
IsPeerReviewed true
IsScholarly true
Issue 2
Keywords median frequency
correlation
mean frequency
root mean square
time-frequency spectrum analysis
isometric contraction
muscle fatigue
mean fre-quency
Language English
License http://www.springer.com/tdm
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c2180-d72d526bf61e7919da1c2d714690dd3e419f7b32a0f7b8cf4ba1d0d0b24d5e743
Notes 12-1248/T
muscle fatigue; isometric contraction; time-frequency spectrum analysis; median frequency; mean frequency; root mean square; correlation
In order to detect and assess the muscle fatigue state with the surface electromyography(sEMG) characteristic parameters,this paper carried out a series of isometric contraction experiments to induce the fatigue on the forearm muscles from four subjects,and recorded the sEMG signals of the flexor carpi ulnaris.sEMG’s median frequency(MDF) and mean frequency(MF) were extracted by short term Fourier transform(STFT),and the root mean square(RMS) of wavelet coefficients in the frequency band of 5—45 Hz was obtained by continuous wavelet transform(CWT).The results demonstrate that both MDF and MF show downward trends within 1 min; however,RMS shows an upward trend within the same time.The three parameters are closely correlated with absolute values of mean correlation coefficients greater than 0.8.It is suggested that the three parameters above can be used as reliable indicators to evaluate the level of muscle fatigue during isometric contractions.
PageCount 5
ParticipantIDs wanfang_journals_tianjdxxb_e201402010
crossref_primary_10_1007_s12209_014_2181_2
springer_journals_10_1007_s12209_014_2181_2
chongqing_primary_49167034
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 20140400
PublicationDateYYYYMMDD 2014-04-01
PublicationDate_xml – month: 4
  year: 2014
  text: 20140400
PublicationDecade 2010
PublicationPlace Heidelberg
PublicationPlace_xml – name: Heidelberg
PublicationTitle Transactions of Tianjin University
PublicationTitleAbbrev Trans. Tianjin Univ
PublicationTitleAlternate Transactions of Tianjin University
PublicationTitle_FL Transactions of Tianjin University
PublicationYear 2014
Publisher Tianjin University
Publisher_xml – name: Tianjin University
References Soo, Sugi, Yokoi (CR17) 2008
Logan (CR18) 2010
Crenshaw, Karlsson, Gerdle (CR14) 1997; 160
Duchêne, Goubel (CR10) 1993; 21
Enoka, Baudry, Rudroff (CR4) 2011; 21
Beck, Housh, Johnson (CR12) 2005; 15
Cifrek, Medved, Tonković (CR7) 2009; 24
Ito, Hotta, Abe (CR8) 2013
Yan, You, Chen (CR16) 2009; 15
Disselhorst-Klug, Schmitz-Rode, Rau (CR5) 2009; 24
Xiang, Tian, Xu (CR2) 2011; 17
Rainoldi, Galardi, Maderna (CR11) 1999; 9
Barandun, von Tscharner, Meuli-Simmen (CR13) 2009; 19
Zaman, Macisaac, Parker (CR9) 2011
Zhang, Liu, Chan (CR15) 2010; 20
Cashaback, Cluff, Potvin (CR6) 2013; 23
Avela, Kyröläinen, Komi (CR1) 2001; 85
Enoka, Duchateau (CR3) 2008; 586
M Cifrek (2181_CR7) 2009; 24
A Rainoldi (2181_CR11) 1999; 9
Z Xiang (2181_CR2) 2011; 17
Z Yan (2181_CR16) 2009; 15
A G Crenshaw (2181_CR14) 1997; 160
Z G Zhang (2181_CR15) 2010; 20
M Barandun (2181_CR13) 2009; 19
R M Enoka (2181_CR4) 2011; 21
C Disselhorst-Klug (2181_CR5) 2009; 24
J Duchêne (2181_CR10) 1993; 21
J Avela (2181_CR1) 2001; 85
T W Beck (2181_CR12) 2005; 15
R M Enoka (2181_CR3) 2008; 586
K Ito (2181_CR8) 2013
S A Zaman (2181_CR9) 2011
J G Cashaback (2181_CR6) 2013; 23
Y Soo (2181_CR17) 2008
M Logan (2181_CR18) 2010
References_xml – volume: 19
  start-page: 65
  issue: 1
  year: 2009
  end-page: 74
  ident: CR13
  article-title: Frequency and conduction velocity analysis of the abductor pollicis brevis muscle during early fatigue [J]
  publication-title: Journal of Electromyography and Kinesiology
  doi: 10.1016/j.jelekin.2007.07.003
– volume: 24
  start-page: 327
  issue: 4
  year: 2009
  end-page: 340
  ident: CR7
  article-title: Surface EMG based muscle fatigue evaluation in biomechanics [J]
  publication-title: Clinical Biomechanics
  doi: 10.1016/j.clinbiomech.2009.01.010
– volume: 15
  start-page: 300
  issue: 4
  year: 2009
  end-page: 307
  ident: CR16
  article-title: Motion classification of EMG signals based on wavelet packet transform and LS-SVMs ensemble [J]
  publication-title: Transactions of Tianjin University
  doi: 10.1007/s12209-009-0053-y
– volume: 20
  start-page: 89
  issue: 1
  year: 2010
  end-page: 101
  ident: CR15
  article-title: Time-dependent power spectral density estimation of surface electromyography during isometric muscle contraction: Methods and comparisons [J]
  publication-title: Journal of Electromyography and Kinesiology
  doi: 10.1016/j.jelekin.2008.09.007
– year: 2010
  ident: CR18
  publication-title: : [M]
– year: 2011
  ident: CR9
  article-title: Repeatability of surface EMG-based single parameter muscle fatigue as-sessment strategies in static and cyclic contractions [C]
  publication-title: 33 . Boston, USA
– year: 2013
  ident: CR8
  article-title: Detection of muscle fatigue during low-level isometric contraction using recurrence quantification analysis[C]
  publication-title: ( ). Beijing, China
– volume: 9
  start-page: 105
  issue: 2
  year: 1999
  end-page: 119
  ident: CR11
  article-title: Repeatability of surface EMG variables during voluntary isometric contractions of the biceps brachii muscle [J]
  publication-title: Journal of Electromyography and Kinesiology
  doi: 10.1016/S1050-6411(98)00042-X
– volume: 586
  start-page: 11
  issue: 1
  year: 2008
  end-page: 23
  ident: CR3
  article-title: Muscle fatigue: What, why and how it influences muscle function [J]
  publication-title: The Journal of Physiology
  doi: 10.1113/jphysiol.2007.139477
– volume: 15
  start-page: 190
  issue: 2
  year: 2005
  end-page: 199
  ident: CR12
  article-title: Comparison of Fourier and wavelet transform procedures for examining the mechanomyographic and electromyographic frequency domain responses during fatiguing isokinetic muscle actions of the biceps brachii [J]
  publication-title: Journal of Electromyography and Kinesiology
  doi: 10.1016/j.jelekin.2004.08.007
– year: 2008
  ident: CR17
  article-title: Simultaneous measurement of force and muscle fatigue using frequency-band wavelet analysis [C]
  publication-title: 30 . Vancouver, Canada
– volume: 21
  start-page: 208
  issue: 2
  year: 2011
  end-page: 219
  ident: CR4
  article-title: Unraveling the neurophysiology of muscle fatigue [J]
  publication-title: Journal of Electromyography and Kinesiology
  doi: 10.1016/j.jelekin.2010.10.006
– volume: 23
  start-page: 78
  issue: 1
  year: 2013
  end-page: 83
  ident: CR6
  article-title: Muscle fatigue and contraction intensity modulates the complexity of surface electromyography [J]
  publication-title: Journal of Electromyography and Kinesiology
  doi: 10.1016/j.jelekin.2012.08.004
– volume: 24
  start-page: 225
  issue: 3
  year: 2009
  end-page: 235
  ident: CR5
  article-title: Surface electromyography and muscle force: Limits in sEMG-force relationship and new approaches for applications [J]
  publication-title: Clinical Biomechanics
  doi: 10.1016/j.clinbiomech.2008.08.003
– volume: 21
  start-page: 313
  issue: 4
  year: 1993
  end-page: 397
  ident: CR10
  article-title: Surface electromyogram during voluntary contraction: Processing tools and relation to physiological events [J]
  publication-title: Critical Reviews in Biomedical Engineering
– volume: 85
  start-page: 317
  issue: 3/4
  year: 2001
  end-page: 325
  ident: CR1
  article-title: Neuromuscular changes after long-lasting mechanically and electrically elicited fatigue [J]
  publication-title: European Journal of Applied Physiology
  doi: 10.1007/s004210100455
– volume: 17
  start-page: 270
  issue: 4
  year: 2011
  end-page: 274
  ident: CR2
  article-title: Load on bicycle frame during cycling with different speeds and gestures [J]
  publication-title: Transactions of Tianjin University
  doi: 10.1007/s12209-011-1628-y
– volume: 160
  start-page: 353
  issue: 4
  year: 1997
  end-page: 361
  ident: CR14
  article-title: Differential responses in intramuscular pressure and EMG fatigue indicators during low-vs
  publication-title: high-level isometric contractions to fatigue [J]. Acta Physiologica Scandinavica
  doi: 10.1046/j.1365-201X.1997.00168.x
– volume-title: International Federation for Medical and Biological Engineering (IFMBE). Beijing, China
  year: 2013
  ident: 2181_CR8
– volume: 15
  start-page: 190
  issue: 2
  year: 2005
  ident: 2181_CR12
  publication-title: Journal of Electromyography and Kinesiology
  doi: 10.1016/j.jelekin.2004.08.007
– volume-title: 33rd Annual International Conference of the IEEE EMBS. Boston, USA
  year: 2011
  ident: 2181_CR9
– volume: 17
  start-page: 270
  issue: 4
  year: 2011
  ident: 2181_CR2
  publication-title: Transactions of Tianjin University
  doi: 10.1007/s12209-011-1628-y
– volume-title: 30th Annual International Conference of the IEEE EMBS. Vancouver, Canada
  year: 2008
  ident: 2181_CR17
– volume: 24
  start-page: 225
  issue: 3
  year: 2009
  ident: 2181_CR5
  publication-title: Clinical Biomechanics
  doi: 10.1016/j.clinbiomech.2008.08.003
– volume: 21
  start-page: 313
  issue: 4
  year: 1993
  ident: 2181_CR10
  publication-title: Critical Reviews in Biomedical Engineering
– volume: 19
  start-page: 65
  issue: 1
  year: 2009
  ident: 2181_CR13
  publication-title: Journal of Electromyography and Kinesiology
  doi: 10.1016/j.jelekin.2007.07.003
– volume: 20
  start-page: 89
  issue: 1
  year: 2010
  ident: 2181_CR15
  publication-title: Journal of Electromyography and Kinesiology
  doi: 10.1016/j.jelekin.2008.09.007
– volume: 9
  start-page: 105
  issue: 2
  year: 1999
  ident: 2181_CR11
  publication-title: Journal of Electromyography and Kinesiology
  doi: 10.1016/S1050-6411(98)00042-X
– volume: 24
  start-page: 327
  issue: 4
  year: 2009
  ident: 2181_CR7
  publication-title: Clinical Biomechanics
  doi: 10.1016/j.clinbiomech.2009.01.010
– volume-title: Biostatistical Design and Analysis Using R: A Practical Guide [M]
  year: 2010
  ident: 2181_CR18
  doi: 10.1002/9781444319620
– volume: 21
  start-page: 208
  issue: 2
  year: 2011
  ident: 2181_CR4
  publication-title: Journal of Electromyography and Kinesiology
  doi: 10.1016/j.jelekin.2010.10.006
– volume: 85
  start-page: 317
  issue: 3/4
  year: 2001
  ident: 2181_CR1
  publication-title: European Journal of Applied Physiology
  doi: 10.1007/s004210100455
– volume: 15
  start-page: 300
  issue: 4
  year: 2009
  ident: 2181_CR16
  publication-title: Transactions of Tianjin University
  doi: 10.1007/s12209-009-0053-y
– volume: 23
  start-page: 78
  issue: 1
  year: 2013
  ident: 2181_CR6
  publication-title: Journal of Electromyography and Kinesiology
  doi: 10.1016/j.jelekin.2012.08.004
– volume: 160
  start-page: 353
  issue: 4
  year: 1997
  ident: 2181_CR14
  publication-title: high-level isometric contractions to fatigue [J]. Acta Physiologica Scandinavica
  doi: 10.1046/j.1365-201X.1997.00168.x
– volume: 586
  start-page: 11
  issue: 1
  year: 2008
  ident: 2181_CR3
  publication-title: The Journal of Physiology
  doi: 10.1113/jphysiol.2007.139477
SSID ssj0049071
Score 1.9296463
Snippet In order to detect and assess the muscle fatigue state with the surface electromyography(sEMG) characteristic parameters,this paper carried out a series of...
In order to detect and assess the muscle fatigue state with the surface electromyography (sEMG) characteristic parameters, this paper carried out a series of...
In order to detect and assess the muscle fatigue state with the surface electromyography (sEMG) character-istic parameters, this paper carried out a series of...
SourceID wanfang
crossref
springer
chongqing
SourceType Aggregation Database
Index Database
Publisher
StartPage 139
SubjectTerms Engineering
Humanities and Social Sciences
Mechanical Engineering
multidisciplinary
Science
信号特征
傅立叶变换
前臂
平均频率
收缩
肌肉疲劳
表面肌电图
连续小波变换
Title sEMG Feature Analysis on Forearm Muscle Fatigue During Isometric Contractions
URI http://lib.cqvip.com/qk/85460X/201402/49167034.html
https://link.springer.com/article/10.1007/s12209-014-2181-2
https://d.wanfangdata.com.cn/periodical/tianjdxxb-e201402010
Volume 20
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV3PS8MwFA6yXfQgbipu6shBwR8U2jRNl-OQzaHMk4N5KvnVqbBO7Qb7831p022CCJ56aJu2-ZL33te89wWhC-37UnBFPRGHyqOGco-njAFViQWjcSiEsgXOoyc2HNOHSTRxddx5le1eLUkWlnpT7EZIkdtDPeuWPLC79chSdxjEY9KrzC8FtlewLEuVKe-SainztyasoMLrPJt-wuN-OqbqFYpaniwV2XTL7QwO0L6LF3GvBLiBdkzWRHtbKoJN1HDzM8dXTkT6-hCN8v7oHqem0O3EwkmP4HmGIUq1_7HxbJlDizgFaKZLg8t6RfyWz2d2ky2FiyT2suwhP0LjQf_5bui5rRM8BV_mezomOiJMpiwwMQ-4FoEiOg4sGdY6NDTgaSxDInw4dFVKpQi0r31JqI4MRBXHqJbNM3OCMCOAmjF-CBBSpcHDa-ZLruzunlrSqIXa6z5MPkqJjIRC1Am2hLbQTdWp63MboWSLRgJoJBaNhLTQbdXtiZtJ-V9XXzpkNhdbo_iuVyuZGGKpo13qb_-r1VO0a-8sc3POUG3xtTTnEHYsZAfVe_cvj_1OMdy-ARhhz3o
linkProvider Springer Nature
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LS8NAEF6kHtSD2KrY-tqDgg8CyWaTNMcirVWbnlrobdlXqkITNS305zubR1tBBE85ZJkk82XnsTvzLUJXyrYFDyW1eOBKi2oaWmHs-5CqBNyngcu5NA3O0dDvj-nzxJuUfdxZVe1ebUnmlnrd7EZIXttDLeOWLLC72xALtE0d15h0KvNLIdvLsyyTKtOwTaqtzN9EGEKF1zSZfsLjfjqm6hXyXp4k5sl0w-30DtB-GS_iTgFwHW3ppIH2NlgEG6hezs8M35Qk0reHKMq60SOOdc7biXlJPYLTBEOUatax8WyRgUQcAzTThcZFvyJ-y9KZOWRL4ryIvWh7yI7QuNcdPfSt8ugES8KX2ZYKiPKIL2Lf0UHohIo7kqjAMcmwUq6mThgHwiXchktbxlRwR9nKFoQqT0NUcYxqSZroE4R9AqhpbbsAIZUKPLzybRFKc7qnEtRrotZKh-yjoMhgFKJOsCW0ie4qpa7urYmSDRoM0GAGDUaa6L5SOytnUvbX6OsSmfVgYxTf1XIpmCYmdTRb_a1_Sb1EO_1RNGCDp-HLKdo1Uoo6nTNUm38t9DmEIHNxkf9y34Dl0Nk
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1JS8NAFB5EQfQgtiq2bnNQcCF0MpkkzbFoa11aPFjoLcyWqtCkmhb6832Tpa0ggqccMrwk8828JfPe9xA6V4QIHkhmcd-RFtMssILI8yBU8bnHfIdzaQqce32vO2CPQ3dY9DlNy2z38kgyr2kwLE3xtDFRUWNZ-EZplufDLGOiLNDBG6CNbbOsB7RVqmIGkV8WcZmwmQVNWh5r_ibCkCu8JfHoEx7900iVr5PV9cQRj0crJqizi3YK3xG3crAraE3HVbS9wihYRZVir6b4siCUvtpDvbTdu8eRzjg8MS9oSHASY_BYzT9tPJ6lIBFHANNopnFeu4jf02RsGm5JnCW05yUQ6T4adNqvt12raKNgSfgyYimfKpd6IvJs7Qd2oLgtqfJtExgr5WhmB5EvHMoJXJoyYoLbiigiKFOuBg_jAK3HSawPEfYoIKg1cQBOJhVYe-UREUjT6VMJ5tZQfTGH4SSnywgZeKCgV1gNXZeTuri3JE02aISARmjQCGkN3ZTTHha7Kv1r9EWBzHKwUZAfaj4XoaYmjDTH_vV_ST1Dmy93nfD5of90hLaMkDxl5xitT79m-gS8kak4zVbcN8qM1RU
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=sEMG+Feature+Analysis+on+Forearm+Muscle+Fatigue+During+Isometric+Contractions&rft.jtitle=%E5%A4%A9%E6%B4%A5%E5%A4%A7%E5%AD%A6%E5%AD%A6%E6%8A%A5%EF%BC%88%E8%8B%B1%E6%96%87%E7%89%88%EF%BC%89&rft.au=Ming+Dong&rft.au=Wang+Xin&rft.au=Xu+Rui&rft.au=Qiu+Shuang&rft.date=2014-04-01&rft.issn=1006-4982&rft.issue=2&rft.spage=139&rft.epage=143&rft_id=info:doi/10.1007%2Fs12209-014-2181-2&rft.externalDocID=tianjdxxb_e201402010
thumbnail_s http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=http%3A%2F%2Fimage.cqvip.com%2Fvip1000%2Fqk%2F85460X%2F85460X.jpg
http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=http%3A%2F%2Fwww.wanfangdata.com.cn%2Fimages%2FPeriodicalImages%2Ftianjdxxb-e%2Ftianjdxxb-e.jpg