Effect of misalignment of analytical centers on higher-order aberration

[Purpose] Effect of misalignment of the analytical centers on higher-order aberration was examined. [Cases and Methods] The subjects were divided into a group of phakia; 23 eyes in 23 subjects with no disorder other than ametropia, and an IOL group; 23 eyes in 23 subjects implanted with intraocular...

Full description

Saved in:
Bibliographic Details
Published inJAPANESE ORTHOPTIC JOURNAL Vol. 35; pp. 69 - 76
Main Authors Kuraoka, Sachiko, Suto, Chikako, Shimamura, Emiko, Sato, Chiaki, Takahashi, Midori
Format Journal Article
LanguageEnglish
Published JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS 2006
Subjects
Online AccessGet full text

Cover

Loading…
Abstract [Purpose] Effect of misalignment of the analytical centers on higher-order aberration was examined. [Cases and Methods] The subjects were divided into a group of phakia; 23 eyes in 23 subjects with no disorder other than ametropia, and an IOL group; 23 eyes in 23 subjects implanted with intraocular lens were evaluated with using a Hartmann-Shack wavefront sensor (KR-9000PW™; Topcon). Analysis was performed at the center of pupil and the center of corneal reflex in order to obtain the corneal aberration and the total ocular aberration (comalike aberration, spherical-like aberration and total higher-order aberration) at pupil diameter of 4mm. (1) Misalignment of the analytical centers (distance between the center of pupil and the center of corneal reflex) (2) aberration amount in analysis at the center of pupil and the center of corneal reflex (3) change quantity of aberration (absolute value of the difference between the center of pupil and the center of corneal reflex) (4) correlation between the misalignment of the analytical centers and the change quantity of aberration were examined. [Results] (1) Misalignment of the analytical centers did not present significant difference between the two groups. (2) Corneal aberration presented significant difference in both groups for comalike aberration and total higher-order aberration, while total ocular aberration presented significant difference in the IOL group for all aberrations. (3) In change quantity of aberration, corneal aberration did not present significant difference between the two groups, while total ocular aberration were significantly larger in the IOL group than in the group of phakia for comalike aberration and total higher-order aberration. (4) Corneal aberration increased in the change quantity of aberration as the misalignment in the centers of analysis intensified, in both groups. Total ocular aberration did not indicate relation with misalignment of the analytical centers in the group of phakia, while positive correlation with the misalignment of the analytical centers was observed in IOL group. [Conclusion] Misalignment of the analytical centers has greater influence on eyes with IOL than on the phakic eyes. Lack of mydriasis or concentrical mydriasis may alter the center of pupil, thus resulting in misalignment of the analytical centers; the measurements should be taken with the pupil uniformly open.
AbstractList [Purpose] Effect of misalignment of the analytical centers on higher-order aberration was examined. [Cases and Methods] The subjects were divided into a group of phakia; 23 eyes in 23 subjects with no disorder other than ametropia, and an IOL group; 23 eyes in 23 subjects implanted with intraocular lens were evaluated with using a Hartmann-Shack wavefront sensor (KR-9000PW™; Topcon). Analysis was performed at the center of pupil and the center of corneal reflex in order to obtain the corneal aberration and the total ocular aberration (comalike aberration, spherical-like aberration and total higher-order aberration) at pupil diameter of 4mm. (1) Misalignment of the analytical centers (distance between the center of pupil and the center of corneal reflex) (2) aberration amount in analysis at the center of pupil and the center of corneal reflex (3) change quantity of aberration (absolute value of the difference between the center of pupil and the center of corneal reflex) (4) correlation between the misalignment of the analytical centers and the change quantity of aberration were examined. [Results] (1) Misalignment of the analytical centers did not present significant difference between the two groups. (2) Corneal aberration presented significant difference in both groups for comalike aberration and total higher-order aberration, while total ocular aberration presented significant difference in the IOL group for all aberrations. (3) In change quantity of aberration, corneal aberration did not present significant difference between the two groups, while total ocular aberration were significantly larger in the IOL group than in the group of phakia for comalike aberration and total higher-order aberration. (4) Corneal aberration increased in the change quantity of aberration as the misalignment in the centers of analysis intensified, in both groups. Total ocular aberration did not indicate relation with misalignment of the analytical centers in the group of phakia, while positive correlation with the misalignment of the analytical centers was observed in IOL group. [Conclusion] Misalignment of the analytical centers has greater influence on eyes with IOL than on the phakic eyes. Lack of mydriasis or concentrical mydriasis may alter the center of pupil, thus resulting in misalignment of the analytical centers; the measurements should be taken with the pupil uniformly open.
Author Shimamura, Emiko
Kuraoka, Sachiko
Suto, Chikako
Sato, Chiaki
Takahashi, Midori
Author_xml – sequence: 1
  fullname: Kuraoka, Sachiko
  organization: Department of Ophthalmology, Saiseikai Kurihashi Hospital
– sequence: 2
  fullname: Suto, Chikako
  organization: Department of Ophthalmology, Saiseikai Kurihashi Hospital
– sequence: 3
  fullname: Shimamura, Emiko
  organization: Department of Ophthalmology, Saiseikai Kurihashi Hospital
– sequence: 4
  fullname: Sato, Chiaki
  organization: Department of Ophthalmology, Saiseikai Kurihashi Hospital
– sequence: 5
  fullname: Takahashi, Midori
  organization: Department of Ophthalmology, Saiseikai Kurihashi Hospital
BookMark eNpNkM1uwjAQhK2KSqWUe495gaRrm_jnWCFKkZB6ac_W4tgkKNjIzoW3bygV7R52Nav55jCPZBJicIQ8U6gWTPCXQ0xDG09DZyteV0LfkSlVipea0XpCpsCVLGsq2QOZ53yAcbjSlNMpWa-8d3Yooi-OXca-24ejCz8aA_bnMRL7wo4vl3IRQ9F2-9alMqbGpQJ3LiUcuhieyL3HPrv5752Rr7fV5_K93H6sN8vXbWkZCF1qEKBrVN4LCjXT9Y6pRrmmkZR6zSwsLGtgIZDJRirplB8pYAAeJVoQfEbgmmtTzDk5b06pO2I6Gwrm0oX568Lw2gg9IpsrcsgD7t0NwDR6evcPoFrKCwTXJfTNY1tMxgX-DRRucXE
ContentType Journal Article
Copyright JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS
Copyright_xml – notice: JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS
DBID AAYXX
CITATION
DOI 10.4263/jorthoptic.35.69
DatabaseName CrossRef
DatabaseTitle CrossRef
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
EISSN 1883-9215
EndPage 76
ExternalDocumentID 10_4263_jorthoptic_35_69
article_jorthoptic1977_35_0_35_0_69_article_char_en
GroupedDBID ALMA_UNASSIGNED_HOLDINGS
JSF
KQ8
RJT
AAYXX
CITATION
ID FETCH-LOGICAL-c2069-906095a8ff6105295b28d8edd711f92c04c2d046a27d787e8f0690200fa7ac063
ISSN 0387-5172
IngestDate Fri Aug 23 04:01:59 EDT 2024
Wed Apr 05 15:04:44 EDT 2023
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed false
IsScholarly true
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c2069-906095a8ff6105295b28d8edd711f92c04c2d046a27d787e8f0690200fa7ac063
OpenAccessLink https://www.jstage.jst.go.jp/article/jorthoptic1977/35/0/35_0_69/_article/-char/en
PageCount 8
ParticipantIDs crossref_primary_10_4263_jorthoptic_35_69
jstage_primary_article_jorthoptic1977_35_0_35_0_69_article_char_en
PublicationCentury 2000
PublicationDate 2006
PublicationDateYYYYMMDD 2006-01-01
PublicationDate_xml – year: 2006
  text: 2006
PublicationDecade 2000
PublicationTitle JAPANESE ORTHOPTIC JOURNAL
PublicationTitleAlternate Jpn. Orthopt. J.
PublicationYear 2006
Publisher JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS
Publisher_xml – name: JAPANESE ASSOCIATION OF CERTIFIED ORTHOPTISTS
References 12) Stiles WS, Crawford BH: The luminous efficiency of rays entering the pupil at different points. Proc R Soc London Ser B112: 428-450, 1933
5) 酒井幸弘, 宇陀恵子, 山田裕子, 内藤尚久, 小島隆司, 市川一夫, 他:ARK-10000を用いた波面収差解析の評価. 日視会誌31:89-94, 2002
3) 後藤浩也, 前田直之:Hartmann-Shack波面センサー. あたらしい眼科21(3):289-296, 2004
1) 黒田輝仁:Hartmann-Shack波面センサー. 角膜形状解析の基礎と臨床:眼科診療プラクティス89. 453-459, 2002
4) 不二門尚:II波面収差解析 波面光学と幾何光学:角膜トポグラファーと波面センサー. 96-103, メジカルビュー社, 東京, 2002
14) He JC, Marcos S, Webb RH, Burns SA: Measurement of the wave-front aberration of the eye by a fast psychophysical procedure. J Opt Soc Am A15: 2449-2456, 1998
6) 大鹿哲郎, 岡本周子, 園尾純一郎, 平塚健太郎, 川名啓介, 坂田典繁, 他:眼科検査診断法 視覚の質quality of visionを測る. 日眼会誌108:770-808, 2004
11) Uozato H, Guyton DL: Centering corneal surgical procedures. Am J Ophthalmol 103: 264-275, 1987
2) 三橋俊文:波面センサーと収差. 診療に役立つ眼光学. 眼科診療プラクティス71. 111-113, 2001
10) Artal P, Antonio G, Berrio E, Williams D: Compensation of corneal aberration by internal optics in the human eye. Journal of Vision 1: 1-8, 2001
15) 大川賀孝, 不二門尚, 黒田輝仁, 二宮さゆり, 前田直之, 田野保雄, 他:眼内レンズの傾き・偏位の高次収差に及ぼす影響. 日眼会誌106臨増:214, 2002
9) Amano S, Amano Y, Yamagami S, Miyai T, Miyata K, Samejima T et al: Age-related changes in corneal and ocular higher-order wavefront aberration. Am J Ophthalmol. 137 (6): 998-992, 2004
7) Oshika T, Klyce SD, Applegate RA: Changes in corneal wavefront aberrations with aging. Invest Ophtalmol Vis Sci 40: 1351-1355, 1999
8) 伊藤美沙絵, 清水公也, 魚里博, 矢野隆, 関口沙知子, 田村千春, 他:高次波面収差の年齢変化. 日眼会誌108臨増:269, 2004
13) 魚里博:屈折矯正手術におけるセンタリングについて. 視覚の科学15(3):138-148, 1994
References_xml
SSID ssj0000389131
ssib053390835
Score 1.6271939
Snippet [Purpose] Effect of misalignment of the analytical centers on higher-order aberration was examined. [Cases and Methods] The subjects were divided into a group...
SourceID crossref
jstage
SourceType Aggregation Database
Publisher
StartPage 69
SubjectTerms analysis at the center of corneal reflex
analysis at the center of pupil
Hartmann-Shack wavefront sensor
higher-order aberration
misalignment of the analytical centers
Title Effect of misalignment of analytical centers on higher-order aberration
URI https://www.jstage.jst.go.jp/article/jorthoptic1977/35/0/35_0_69/_article/-char/en
Volume 35
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
ispartofPNX JAPANESE ORTHOPTIC JOURNAL, 2006/08/31, Vol.35, pp.69-76
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9QwELaWwoFLBQJEaUE50AOKsiTOyzlCKVSsVAmplXqLHD9IWG2Cll1V7a9nxs7DXYFEuVgby3aymcnn8TwJecvzPGeVFoGWDA4oEu27rEIXKyFVFktGtfHyPc_OLpOvV-nVbHbtRpdsqrm4_WNcyf9QFfqArhglew_KjotCB_wG-kILFIb2n2jcpx5GE3nzCwTq75NpH3ONWDU1ul9ilC6QuTZOHYFJt-nzSq3XE116AfW8qRFB6qY9PkmP2Sd_sYWbo0-Xv7ixXUve-HDtGIF4t-RWvSzqZtlNhqaNVcRCJ3e662bFV1tT4Mg_XbkT-DgBBNu7CgkHsTBRbxrZWjxzZRGVMSA_tTGbA-TGqYOZtlRLv_vaYjC7uI5Z5RHX0ZTVAZSKeZzOh3luCu2drW10OISjDq5RTiuUcVpmxQPykAJCoS_o4tsIRCACF-GQh85s6caaa6ovDn_Rmrxx0fe7j3VHxHn0A6T8wUPQCC0XT8h-f9rwPljWeUpmqn1Gvli28TrtuWyD1xPbeD3beF3ruWzjTWzznFx-Pr04OQv6ehqBoGFWBEWI2QU50xpkZjTwVpRJpqTMo0gXVISJoDJMMk5zCTiumMY01kBizXMuQJZ9QfbarlUviSd5VGU8VJFmNInhk85okulKYz67Ko3iA_JueAXlT5s2pfwbDQ7IR_uOxpH9B-WMjOCYgqND22TFOAaDEwELXt3jhofk8aRIOyJ7m_VWvQbRclO9MWzwG1mgftk
link.rule.ids 315,783,787,4031,27935,27936,27937
linkProvider Colorado Alliance of Research Libraries
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Effect+of+misalignment+of+analytical+centers+on+higher-order+aberration&rft.jtitle=Nihon+Shin%C5%8D+Kunrenshi+Ky%C5%8Dkai+shi&rft.au=Kuraoka%2C+Sachiko&rft.au=Suto%2C+Chikako&rft.au=Shimamura%2C+Emiko&rft.au=Sato%2C+Chiaki&rft.date=2006&rft.issn=0387-5172&rft.eissn=1883-9215&rft.volume=35&rft.spage=69&rft.epage=76&rft_id=info:doi/10.4263%2Fjorthoptic.35.69&rft.externalDBID=n%2Fa&rft.externalDocID=10_4263_jorthoptic_35_69
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0387-5172&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0387-5172&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0387-5172&client=summon