Piping Cracks in JPDR, (II)

Ultrasonic and radiographic examinations of weldments in the primary piping of the Japan Power Demonstration Reactor (JPDR) revealed crack indications in two reactor vessel nozzle safe-end to pipe joints CS-1 and UL-1, while on the joint FW-132 a crack-like indication was given only on the ultrasoni...

Full description

Saved in:
Bibliographic Details
Published inJournal of nuclear science and technology Vol. 15; no. 11; p. 856
Main Authors FUTAMURA, Yoshiaki, KINOSHITA, Takehiko, TORIKAI, Kinichi
Format Journal Article
LanguageEnglish
Published Tokyo Taylor & Francis Ltd 01.11.1978
Online AccessGet full text