Development of a Device to Measure Human Hair Luster
Evaluating human hair luster is important to develop hair-care products. Many methods to measure human hair luster have been proposed so far. However, they have some disadvantages: some method needs to cut subject's hair and some needs a long time of period. To solve these problems, a new devic...
Saved in:
Published in | Journal of Society of Cosmetic Chemists of Japan Vol. 33; no. 2; pp. 140 - 146 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
The Society of Cosmetic Chemists of Japan
1999
|
Subjects | |
Online Access | Get full text |
ISSN | 0387-5253 1884-4146 |
DOI | 10.5107/sccj.33.2_140 |
Cover
Loading…
Abstract | Evaluating human hair luster is important to develop hair-care products. Many methods to measure human hair luster have been proposed so far. However, they have some disadvantages: some method needs to cut subject's hair and some needs a long time of period. To solve these problems, a new device to measure human hair luster is developed. This new device has some excellent features: It can measure human hair luster accurately without cutting hair. The measurement is not affected by subject's hairstyle and/or color. The device needs extremely short time of period. The relationship between sensory data of human hair luster and the measurement has highly correlative coefficient, so the measurement by this new device is effective for evaluating human hair luster. |
---|---|
AbstractList | Evaluating human hair luster is important to develop hair-care products. Many methods to measure human hair luster have been proposed so far. However, they have some disadvantages: some method needs to cut subject's hair and some needs a long time of period. To solve these problems, a new device to measure human hair luster is developed. This new device has some excellent features: It can measure human hair luster accurately without cutting hair. The measurement is not affected by subject's hairstyle and/or color. The device needs extremely short time of period. The relationship between sensory data of human hair luster and the measurement has highly correlative coefficient, so the measurement by this new device is effective for evaluating human hair luster. |
Author | Tango, Yutaka Shimmoto, Koichi |
Author_xml | – sequence: 1 fullname: Tango, Yutaka organization: Fundamental Research Laboratory, KOSÉ Corporation – sequence: 1 fullname: Shimmoto, Koichi organization: Fundamental Research Laboratory, KOSÉ Corporation |
BookMark | eNo9j8tOwzAQRS1UJELpkr1_wMHPxFmiFihSERtYW_ZkAqmapLJTJP6ePmhXI90590rnlkz6oUdC7gXPjeDlQwJY50rl0gnNr0gmrNVMC11MSMaVLZmRRt2QWUpt4NyISgvDM6IX-IObYdthP9KhoZ7ugxaQjgN9Q592Eely1_meLn0b6WqXRox35Lrxm4Sz_zsln89PH_MlW72_vM4fVwxEZTiTtTZGe954Y8GoGupgZSGkkqUAZdFqA1ByK4MO0iKEGgofQAUoJMq6UFPCTrsQh5QiNm4b287HXye4O1i7g7VTyh2t9_zixK_T6L_wQvs4trDBIy2qsjo1zrXLG759dNirP1hEZEA |
ContentType | Journal Article |
Copyright | Socity of Cosmetic Chemists of Japan |
Copyright_xml | – notice: Socity of Cosmetic Chemists of Japan |
DBID | AAYXX CITATION |
DOI | 10.5107/sccj.33.2_140 |
DatabaseName | CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
EISSN | 1884-4146 |
EndPage | 146 |
ExternalDocumentID | 10_5107_sccj_33_2_140 article_sccj1979_33_2_33_2_140_article_char_en |
GroupedDBID | ALMA_UNASSIGNED_HOLDINGS OK1 AAYXX CITATION |
ID | FETCH-LOGICAL-c1950-2d4554a0fa58c53dcdb826123271c38e845cc7082b4b28ecbdc6abc3bc62e2d63 |
ISSN | 0387-5253 |
IngestDate | Tue Jul 01 03:49:44 EDT 2025 Wed Sep 03 06:29:31 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | false |
Issue | 2 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c1950-2d4554a0fa58c53dcdb826123271c38e845cc7082b4b28ecbdc6abc3bc62e2d63 |
OpenAccessLink | https://www.jstage.jst.go.jp/article/sccj1979/33/2/33_2_140/_article/-char/en |
PageCount | 7 |
ParticipantIDs | crossref_primary_10_5107_sccj_33_2_140 jstage_primary_article_sccj1979_33_2_33_2_140_article_char_en |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 1900 |
PublicationDate | 1999 |
PublicationDateYYYYMMDD | 1999-01-01 |
PublicationDate_xml | – year: 1999 text: 1999 |
PublicationDecade | 1990 |
PublicationTitle | Journal of Society of Cosmetic Chemists of Japan |
PublicationTitleAlternate | Journal of Society of Cosmetic Chemists of Japan |
PublicationYear | 1999 |
Publisher | The Society of Cosmetic Chemists of Japan |
Publisher_xml | – name: The Society of Cosmetic Chemists of Japan |
References | 6) 富永昌治, 大橋伸一郎, 情報処理学会論文誌, 33, 37-45 (1992 4) C. R. Robbins (本間意富訳), 毛髪の科学, フレグランスジャーナル社 (1982) p. 162-213 2) 前田哲夫, 岡田正紀, 渡辺 博, 原 烈, 粧技誌, 25, 215-222 (1992 1) A. Guiolet, J. C. Garson, J. L. Lerecque, Int. J. Cosmet. Sci., 9, 111-124 (1987 5) S. A. Shafer, Color Res. Appl., 10, 210-218 (1985 3) 渡辺 靖, 田村健夫, 原田裕文, 八木原陽一, ヘアサイエンス, 日本毛髪科学協会 (1986) p. 3-15 7) 日本色彩学会編, 新編色彩科学ハンドブック, 東京大学出版会 (1980) p. 625-644 |
References_xml | – reference: 3) 渡辺 靖, 田村健夫, 原田裕文, 八木原陽一, ヘアサイエンス, 日本毛髪科学協会 (1986) p. 3-15 – reference: 7) 日本色彩学会編, 新編色彩科学ハンドブック, 東京大学出版会 (1980) p. 625-644 – reference: 4) C. R. Robbins (本間意富訳), 毛髪の科学, フレグランスジャーナル社 (1982) p. 162-213 – reference: 1) A. Guiolet, J. C. Garson, J. L. Lerecque, Int. J. Cosmet. Sci., 9, 111-124 (1987) – reference: 2) 前田哲夫, 岡田正紀, 渡辺 博, 原 烈, 粧技誌, 25, 215-222 (1992) – reference: 6) 富永昌治, 大橋伸一郎, 情報処理学会論文誌, 33, 37-45 (1992) – reference: 5) S. A. Shafer, Color Res. Appl., 10, 210-218 (1985) |
SSID | ssib005194150 ssib020483907 ssib046621875 |
Score | 1.2657974 |
Snippet | Evaluating human hair luster is important to develop hair-care products. Many methods to measure human hair luster have been proposed so far. However, they... |
SourceID | crossref jstage |
SourceType | Index Database Publisher |
StartPage | 140 |
SubjectTerms | color dichromatic reflection model diffuse reflection direct measurement gonio photometric method hair hairstyle light emitting diode luster photodiode small device specular reflection |
Title | Development of a Device to Measure Human Hair Luster |
URI | https://www.jstage.jst.go.jp/article/sccj1979/33/2/33_2_140/_article/-char/en |
Volume | 33 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | Journal of Society of Cosmetic Chemists of Japan, 1999/06/20, Vol.33(2), pp.140-146 |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LS8QwEA6-Dl5EUfFNDuJl6WqTPg8eRJTFF4gKeip5ra7iVrR78dc7k6Td-jiol1KySbrpTCZfpjNfCNmGTYPQSqWBlDoKoliYQBgpAs404I1McxNivvP5RdK7iU5u49v6iHufXVLJrnr_Ma_kP1KFMpArZsn-QbJNp1AA9yBfuIKE4forGbciflyeIxTAxEc8ee58f95J3xOD187Z6K2Oxf2ORuvoTYzOKN-eMbWxc-gOg7PBHiewqI5jdsXw3rpY70aVeGoM-9XDAMZuz2XqnJYD9TAY-xSQh6BldJBrN2aOwLdrnFHMMhBj7Sr0VtPRV3jtYC0TGDr6Jb-a-lZfDTVYApu4rNRjl_MuK5pWbULsLwtVEz4IGxfsoMDmBeeFbT5JplmahmjZTi_bFGU5YJTGJiFPMc_HW94oSQDkWD7mZuiOihWfsPvpD36CLjOPgN7ryD8LRq7nyZyXGz1wKrFAJsxwkUQtdaBlnwrq1IFWJfXqQK06UFQH6tRhidwcH10f9gJ_KEag8MTegOkIEKDY64s4UzHXSssMaeA4S0PFM5NFMUw9AHYykiwzSmqVCKm4VAkzTCd8mUwNy6FZIdRgy5xpLfsSP49L2Mz2cwEii_MwT-Uq2anHW7w47pPix1e_Svbd22iq-Slhq0FXuata129-xsxCmMhrv33QOpl1tBnoAtsgU9XryGwCKKzklpX6B08wYEI |
linkProvider | Colorado Alliance of Research Libraries |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Development+of+a+Device+to+Measure+Human+Hair+Luster&rft.jtitle=Journal+of+Society+of+Cosmetic+Chemists+of+Japan&rft.au=Tango%2C+Yutaka&rft.au=Shimmoto%2C+Koichi&rft.date=1999&rft.issn=0387-5253&rft.eissn=1884-4146&rft.volume=33&rft.issue=2&rft.spage=140&rft.epage=146&rft_id=info:doi/10.5107%2Fsccj.33.2_140&rft.externalDBID=n%2Fa&rft.externalDocID=10_5107_sccj_33_2_140 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0387-5253&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0387-5253&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0387-5253&client=summon |