Oral contrast media in CT of the abdomen. Iohexol of different concentrations as a gastrointestinal contrast medium

In a double-blind randomised study 3 different concentrations of iohexol for bowel opacification at CT of the abdomen were compared. Iohexol in a concentration of 4.5 mg I/ml, 6.75 mg I/ml and 9 mg I/ml was used. No significant differences between the 3 preparations of contrast media were found rega...

Full description

Saved in:
Bibliographic Details
Published inActa radiologica (1987) Vol. 36; no. 4; p. 396
Main Authors Lönnemark, M, Magnusson, A
Format Journal Article
LanguageEnglish
Published England 01.07.1995
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:In a double-blind randomised study 3 different concentrations of iohexol for bowel opacification at CT of the abdomen were compared. Iohexol in a concentration of 4.5 mg I/ml, 6.75 mg I/ml and 9 mg I/ml was used. No significant differences between the 3 preparations of contrast media were found regarding the contrast effect, the distribution or patient tolerance. When using iohexol as a bowel contrast medium at CT the concentration of 4.5 mg I/ml is sufficient for bowel opacification.
ISSN:0284-1851
DOI:10.1080/02841859509173396