A study on SN characteristic of line spectrum sensor in practical use
Remote sensing is a technology which acquires the physical information of a measuring object indirectly based on the radiation acquired by a remote sensor. Therefore, to systematize the technology of converting the radiation to physical quantity is an important subject for remote sensing to spread i...
Saved in:
Published in | Journal of the Japan society of photogrammetry and remote sensing Vol. 47; no. 4; pp. 4 - 12 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
Japan Society of Photogrammetry and Remote Sensing
2008
|
Online Access | Get full text |
ISSN | 0285-5844 1883-9061 |
DOI | 10.4287/jsprs.47.4_4 |
Cover
Abstract | Remote sensing is a technology which acquires the physical information of a measuring object indirectly based on the radiation acquired by a remote sensor. Therefore, to systematize the technology of converting the radiation to physical quantity is an important subject for remote sensing to spread in all the natural science fields. We have been developed a portable line spectrum radiometer, which are constructed entirely from commercially available components. Developed radiometer has steadiness and lightness with the commercial digital camera as a measurement unit. These two features are important in field use. And, developed radiometer was proven to be effective by actually measuring the sample color chart in the relative comparison of a spectral pattern. In this paper, we describe the instrument design of developed radiometer. Especially, we discusses it through the examination of the signal-noise characteristics based on the emphasis on the measuring a spectral pattern with the high signal-noise characteristics. |
---|---|
AbstractList | Remote sensing is a technology which acquires the physical information of a measuring object indirectly based on the radiation acquired by a remote sensor. Therefore, to systematize the technology of converting the radiation to physical quantity is an important subject for remote sensing to spread in all the natural science fields. We have been developed a portable line spectrum radiometer, which are constructed entirely from commercially available components. Developed radiometer has steadiness and lightness with the commercial digital camera as a measurement unit. These two features are important in field use. And, developed radiometer was proven to be effective by actually measuring the sample color chart in the relative comparison of a spectral pattern. In this paper, we describe the instrument design of developed radiometer. Especially, we discusses it through the examination of the signal-noise characteristics based on the emphasis on the measuring a spectral pattern with the high signal-noise characteristics. |
Author | SUHAMA, Tomoyuki TAKAHASHI, Kazuyoshi SHIMAMURA, Hideki MOCHIZUKI, Kanichiro RIKIMARU, Atsushi |
Author_xml | – sequence: 1 fullname: SUHAMA, Tomoyuki organization: PASCO Corporation – sequence: 1 fullname: RIKIMARU, Atsushi organization: NAGAOKA University of Technology – sequence: 1 fullname: SHIMAMURA, Hideki organization: PASCO Corporation – sequence: 1 fullname: TAKAHASHI, Kazuyoshi organization: NAGAOKA University of Technology – sequence: 1 fullname: MOCHIZUKI, Kanichiro organization: PASCO Corporation |
BookMark | eNo9kMtOwzAQRS1UJErpjg_wB5DixyROllVVHlIFC2Bt2c4YUqVOZKeL_j3pQ53FzOKeGY3OPZmELiAhj5wtQJTqeZv6mBagFqDhhkx5WcqsYgWfkCkTZZ7lJcAdmae0ZWMBYyKvpmS9pGnY1wfaBfr1Qd2ficYNGJs0NI52nrZNQJp6dEPc72jCkLpIm0D7I9c409J9wgdy602bcH6ZM_Lzsv5evWWbz9f31XKTOV4JyISvVSGkcxKst3UhbCm48OBFbmrGrOQo0QFY5QFUjaVgUnnhrbOV9VUhZ-TpfNfFLqWIXvex2Zl40JzpowV9sqBB6dHCiK_O-DYN5hevsInj5y2eYV6p_LJwatf06EJjkP9n3WvQ |
ContentType | Journal Article |
Copyright | Japan Society of Photogrammetry and Remote Sensing |
Copyright_xml | – notice: Japan Society of Photogrammetry and Remote Sensing |
DBID | AAYXX CITATION |
DOI | 10.4287/jsprs.47.4_4 |
DatabaseName | CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Visual Arts |
EISSN | 1883-9061 |
EndPage | 12 |
ExternalDocumentID | 10_4287_jsprs_47_4_4 article_jsprs1975_47_4_47_4_4_article_char_en |
GroupedDBID | ABJNI ACGFS ALMA_UNASSIGNED_HOLDINGS JSF KQ8 RJT ~02 AAYXX CITATION |
ID | FETCH-LOGICAL-c1924-2fd7623cc34bfbd62b8212f4f25ad00b31e3ec44b7f447de82037f2fbcb9bf963 |
ISSN | 0285-5844 |
IngestDate | Tue Jul 01 04:16:06 EDT 2025 Wed Sep 03 06:21:58 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | true |
Issue | 4 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c1924-2fd7623cc34bfbd62b8212f4f25ad00b31e3ec44b7f447de82037f2fbcb9bf963 |
OpenAccessLink | https://www.jstage.jst.go.jp/article/jsprs1975/47/4/47_4_4/_article/-char/en |
PageCount | 9 |
ParticipantIDs | crossref_primary_10_4287_jsprs_47_4_4 jstage_primary_article_jsprs1975_47_4_47_4_4_article_char_en |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2008 |
PublicationDateYYYYMMDD | 2008-01-01 |
PublicationDate_xml | – year: 2008 text: 2008 |
PublicationDecade | 2000 |
PublicationTitle | Journal of the Japan society of photogrammetry and remote sensing |
PublicationTitleAlternate | Journal of the Japan society of photogrammetry and remote sensing |
PublicationYear | 2008 |
Publisher | Japan Society of Photogrammetry and Remote Sensing |
Publisher_xml | – name: Japan Society of Photogrammetry and Remote Sensing |
References | 洲濱智幸, 島村秀樹, 望月貫一郎, 力丸厚, 高橋一義, 2007. 可搬型ライン分光センサの試作, 写真測量とリモートセンシング, vol. 46, no. 6, pp. 36-41. 矢野宏, 2007. 品質工学計算法入門, 日本規格協会, 東京, pp. 74-100. 松田真典, 大澤昭一, 保坂幸男, 金田和文, 山下英生, 2003. 近接リモートセンシングによる水稲の生育診断-デジタルカメラによる葉身窒素含有率の測定-, 日本リモートセンシング学会誌, vol. 23, no. 5, pp. 506-515. 三宅洋一編, 2006. 分光画像処理入門, 東京大学出版会, 東京, 10pp. 安田嘉純, 山本博, 成ヶ澤憲太郎, 1985. II. 分光放射計, 写真測量とリモートセンシング, vol. 24, 特集号I, pp. 19-27. 田口玄一, 1972. 統計解析, 丸善株式会社, 東京, pp. 187-214. Spectral imaging ltd., 2008. eagle_datasheet_ver2-07, http: //www.specim.fi/media/pdf/aisa-datasheets (accessed 22 June. 2008) . |
References_xml | – reference: 三宅洋一編, 2006. 分光画像処理入門, 東京大学出版会, 東京, 10pp. – reference: 洲濱智幸, 島村秀樹, 望月貫一郎, 力丸厚, 高橋一義, 2007. 可搬型ライン分光センサの試作, 写真測量とリモートセンシング, vol. 46, no. 6, pp. 36-41. – reference: 安田嘉純, 山本博, 成ヶ澤憲太郎, 1985. II. 分光放射計, 写真測量とリモートセンシング, vol. 24, 特集号I, pp. 19-27. – reference: 松田真典, 大澤昭一, 保坂幸男, 金田和文, 山下英生, 2003. 近接リモートセンシングによる水稲の生育診断-デジタルカメラによる葉身窒素含有率の測定-, 日本リモートセンシング学会誌, vol. 23, no. 5, pp. 506-515. – reference: Spectral imaging ltd., 2008. eagle_datasheet_ver2-07, http: //www.specim.fi/media/pdf/aisa-datasheets (accessed 22 June. 2008) . – reference: 田口玄一, 1972. 統計解析, 丸善株式会社, 東京, pp. 187-214. – reference: 矢野宏, 2007. 品質工学計算法入門, 日本規格協会, 東京, pp. 74-100. |
SSID | ssj0000400259 |
Score | 1.6497501 |
Snippet | Remote sensing is a technology which acquires the physical information of a measuring object indirectly based on the radiation acquired by a remote sensor.... |
SourceID | crossref jstage |
SourceType | Index Database Publisher |
StartPage | 4 |
Title | A study on SN characteristic of line spectrum sensor in practical use |
URI | https://www.jstage.jst.go.jp/article/jsprs1975/47/4/47_4_4/_article/-char/en |
Volume | 47 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | Journal of the Japan society of photogrammetry and remote sensing, 2008/09/01, Vol.47(4), pp.4-12 |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb5wwELa2aQ_toepTTV_yoTlFbHmYAFIvKE3FdrUrNRuq3BDGtkKjhWhZDskv6M_ujA2UjXJIe7HA2EbMDOPP45kxIZ-E8m3GRWG5gNwsJpzc4lxIKxKhx8Pc9aUOClssj5KUfT_3zyeT3yOvpXbLp8XNnXEl_8NVqAO-YpTsP3B2GBQq4Br4CyVwGMp78Tg22WHR4L9aYgzvKPcyokANIXUs5aZdHzawYtXe531oFHCnbXZcgVYX-mylw6a-xP31Y_8g_IrodFOuzQ1c4zBotmoH40yaoJ0eGV-v6-v2shx2cWbz2SI-TbUC2jYt9BssBfE8TuJVMjMuHTftdT16CvWLeJGe6lGTUshuzN48MdKlgFx8C_CNsRdIo1_D0LMi2-Rf7xWwSbnZCRobaVM2mpaNs_VthY8LPlT4zdWmmbJgyjL2d2LrN_NvzXeDFyKsf7B_pntnLMig9wPy0A0CB51D5z_CwVqHqs7VJ-8NX2WiKHCAz-PX7-CbR78A4vfugRqxnD0jT7ulBo2N3DwnE1m9IE9-lk1rapuX5CSmWoJoXdHVku5KEK0VRQmivQRRI0G0rOggQRQk6BVJv52cHSdWd7CGVeB623KVgDnQKwqPccXFkctDQDCKKdfPhW1zz5GeLBjjgWIsEBJQohcoV_GCR1yByn5N9qq6km8IDZXj8jxguRSChX4YuUp6CnEhc2xbiX1y0JMjuzL5U7K76L5PvhhaDa26v8q0cqLA71rqYniKhAFV8Paer3lHHhuHH7ShvSd7QDz5AVDlln_UDP8DEsl8OQ |
linkProvider | Colorado Alliance of Research Libraries |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=A+study+on+SN+characteristic+of+line+spectrum+sensor+in+practical+use&rft.jtitle=Shashin+sokury%C5%8D+to+rim%C5%8Dto+senshingu&rft.au=SUHAMA%2C+Tomoyuki&rft.au=RIKIMARU%2C+Atsushi&rft.au=TAKAHASHI%2C+Kazuyoshi&rft.au=SHIMAMURA%2C+Hideki&rft.date=2008&rft.issn=0285-5844&rft.eissn=1883-9061&rft.volume=47&rft.issue=4&rft.spage=4&rft.epage=12&rft_id=info:doi/10.4287%2Fjsprs.47.4_4&rft.externalDBID=n%2Fa&rft.externalDocID=10_4287_jsprs_47_4_4 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0285-5844&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0285-5844&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0285-5844&client=summon |