Accreditation of automated complete blood count by the LH750 Analyzer (Beckman Coulter) in Georges Pompidou Hospital (Paris, France)

Preliminary evaluation of quantitative clinical laboratory measurements is a prerequisite for the accreditation of clinical laboratories, according to the French Committee of Accreditation guidelines following the European reference Standard EN ISO 15189. Numerous papers have been published regardin...

Full description

Saved in:
Bibliographic Details
Published inAnnales de biologie clinique (Paris) Vol. 71; no. 6; p. 717
Main Authors Robinet, Sylvain, Lemaire, Pierre, Louis, Gauthier, Vieillefond, Vincent, Daigneau, Yolande, Gaillaud, Emilie, Vincent, Béatrice, Fischer, Anne-Marie, Siguret, Virginie
Format Journal Article
LanguageFrench
Published France 01.11.2013
Subjects
Online AccessGet more information

Cover

Loading…
Abstract Preliminary evaluation of quantitative clinical laboratory measurements is a prerequisite for the accreditation of clinical laboratories, according to the French Committee of Accreditation guidelines following the European reference Standard EN ISO 15189. Numerous papers have been published regarding biochemistry and immunology. However, data are lacking for automated complete blood count accreditation. We report here our experience at Hôpital européen Georges Pompidou hematology laboratory and present the performance characteristics of two mirrored LH750 Beckman-Coulter analysers, including precision, accuracy and uncertainty of measurement.
AbstractList Preliminary evaluation of quantitative clinical laboratory measurements is a prerequisite for the accreditation of clinical laboratories, according to the French Committee of Accreditation guidelines following the European reference Standard EN ISO 15189. Numerous papers have been published regarding biochemistry and immunology. However, data are lacking for automated complete blood count accreditation. We report here our experience at Hôpital européen Georges Pompidou hematology laboratory and present the performance characteristics of two mirrored LH750 Beckman-Coulter analysers, including precision, accuracy and uncertainty of measurement.
Author Robinet, Sylvain
Louis, Gauthier
Vincent, Béatrice
Siguret, Virginie
Lemaire, Pierre
Gaillaud, Emilie
Vieillefond, Vincent
Daigneau, Yolande
Fischer, Anne-Marie
Author_xml – sequence: 1
  givenname: Sylvain
  surname: Robinet
  fullname: Robinet, Sylvain
  organization: Service d'hématologie biologique, Assistance publique-Hôpitaux de Paris, Hôpital européen Georges Pompidou, Paris, France
– sequence: 2
  givenname: Pierre
  surname: Lemaire
  fullname: Lemaire, Pierre
  organization: Service d'hématologie biologique, Assistance publique-Hôpitaux de Paris, Hôpital européen Georges Pompidou, Paris, France
– sequence: 3
  givenname: Gauthier
  surname: Louis
  fullname: Louis, Gauthier
  organization: Service d'hématologie biologique, Assistance publique-Hôpitaux de Paris, Hôpital européen Georges Pompidou, Paris, France
– sequence: 4
  givenname: Vincent
  surname: Vieillefond
  fullname: Vieillefond, Vincent
  organization: Service d'hématologie biologique, Assistance publique-Hôpitaux de Paris, Hôpital européen Georges Pompidou, Paris, France
– sequence: 5
  givenname: Yolande
  surname: Daigneau
  fullname: Daigneau, Yolande
  organization: Service d'hématologie biologique, Assistance publique-Hôpitaux de Paris, Hôpital européen Georges Pompidou, Paris, France
– sequence: 6
  givenname: Emilie
  surname: Gaillaud
  fullname: Gaillaud, Emilie
  organization: Service d'hématologie biologique, Assistance publique-Hôpitaux de Paris, Hôpital européen Georges Pompidou, Paris, France
– sequence: 7
  givenname: Béatrice
  surname: Vincent
  fullname: Vincent, Béatrice
  organization: Service d'hématologie biologique, Assistance publique-Hôpitaux de Paris, Hôpital européen Georges Pompidou, Paris, France
– sequence: 8
  givenname: Anne-Marie
  surname: Fischer
  fullname: Fischer, Anne-Marie
  organization: Service d'hématologie biologique, Assistance publique-Hôpitaux de Paris, Hôpital européen Georges Pompidou, Paris, France, Inserm UMR-S765, Université Paris Descartes, Paris, France
– sequence: 9
  givenname: Virginie
  surname: Siguret
  fullname: Siguret, Virginie
  organization: Service d'hématologie biologique, Assistance publique-Hôpitaux de Paris, Hôpital européen Georges Pompidou, Paris, France, Inserm UMR-S765, Université Paris Descartes, Paris, France
BackLink https://www.ncbi.nlm.nih.gov/pubmed/24342794$$D View this record in MEDLINE/PubMed
BookMark eNo1kMFLwzAYxYMozk2PXuU7bmBnkqZtepzDbcLAHfQ8kvSLVtukpOlhnv3Dnainx48HvwdvTE6dd0jINaNzlktxp7SZc8rSOZUlPyEXrMxokjPGR2Tc9--UMi7T9JyMuEgFL0pxQb4WxgSs6qhi7R14C2qIvlURKzC-7RqMCLrx_gcHF0EfIL4hbDdFRmHhVHP4xADTezQfrXKw9EMTMcygdrBGH16xh93RU1d-gI3vu-NSA9OdCnV_C6ugnMHZJTmzqunx6i8n5GX18LzcJNun9eNysU0MK8qYSC1MppXOdUmtyVnFEHN-7GRqy0pzmaFFTrlAWeaVMtYaYSXjthAo0lzzCbn59XaDbrHad6FuVTjs_-_g34UBYs4
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1684/abc.2013.0892
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
Biology
DocumentTitleAlternate Vérification de méthode en vue de l'accréditation : exemple de l'hémogramme automatisé sur deux analyseurs LH750 Beckman-Coulter à l'Hôpital européen Georges Pompidou
EISSN 1950-6112
ExternalDocumentID 24342794
Genre English Abstract
Journal Article
GeographicLocations France
Paris
GeographicLocations_xml – name: Paris
– name: France
GroupedDBID --K
.GJ
1B1
23M
53G
5GY
ABJNI
ACUKS
ADBBV
AENEX
AI.
ALMA_UNASSIGNED_HOLDINGS
BAWUL
CGR
CUY
CVF
DIK
EBS
ECM
EIF
EJD
EMOBN
F5P
IHE
M41
NPM
NQ-
OK1
P2P
RIG
ROL
RPZ
RXQ
SV3
VH1
ID FETCH-LOGICAL-c179t-8b4c5bab6b90fc61d1ee62c1783f9db285efe2024e896dacffc4f812f74e436b2
IngestDate Thu May 23 23:20:40 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 6
Keywords accreditation
control
complete blood count
quality
Language French
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c179t-8b4c5bab6b90fc61d1ee62c1783f9db285efe2024e896dacffc4f812f74e436b2
PMID 24342794
ParticipantIDs pubmed_primary_24342794
PublicationCentury 2000
PublicationDate 2013 Nov-Dec
PublicationDateYYYYMMDD 2013-11-01
PublicationDate_xml – month: 11
  year: 2013
  text: 2013 Nov-Dec
PublicationDecade 2010
PublicationPlace France
PublicationPlace_xml – name: France
PublicationTitle Annales de biologie clinique (Paris)
PublicationTitleAlternate Ann Biol Clin (Paris)
PublicationYear 2013
SSID ssj0012833
Score 1.9646097
Snippet Preliminary evaluation of quantitative clinical laboratory measurements is a prerequisite for the accreditation of clinical laboratories, according to the...
SourceID pubmed
SourceType Index Database
StartPage 717
SubjectTerms Accreditation - methods
Automation, Laboratory - instrumentation
Automation, Laboratory - standards
Blood Cell Count - instrumentation
Blood Cell Count - standards
Equipment Contamination
France
Hematologic Tests - instrumentation
Hematologic Tests - standards
Hospitals, Public - standards
Humans
Paris
Quality Control
Reproducibility of Results
Risk Management
Sensitivity and Specificity
Uncertainty
Title Accreditation of automated complete blood count by the LH750 Analyzer (Beckman Coulter) in Georges Pompidou Hospital (Paris, France)
URI https://www.ncbi.nlm.nih.gov/pubmed/24342794
Volume 71
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9QwELa2IFAvCMr7pTlwaFXSbpxs7BxLBaxQW1WirXqrYseWIuimKrtI2zO_jl_FjB_ZbHkIuESrWLa8mU8z4_HMfIy90hmvBFrihDhkkxwPHIlUpUp4UY4yIVA7WDoo7h8U4-P8w-nodDD43stamk3Vlr76ZV3J_0gV36FcqUr2HyTbLYov8DfKF58oYXz-lYx3NPX7DF223Y3-bNqiC2pqnyqODrHPTN90lBDO1URY7I3RgPt2JFfUSYLLN0Z_omD-LrFMkxBLioP4ePmXzUNcq6nbWUcyQlMOib0wur666-3U78uMU2vcgCuIaYwvwqRusYvZXRTClaH5e5GP889fq6aXKXRexVI0NOGLXN29duY38B7_NTF6x4GTxlCBow2EySfNRMfsnhDeSLNQ5-esk1fJ5YgOuOmSzva0LQGbfQUsfCXoT4ahkDlZPUVdK9Nsayg9A18PJBfnDiU8z3IuPPHyn0ev9emOQytsRUjStQcUNwr3WejEZaHDK-5ke2kf1I86zL12tnE-ztFddiccTmDHI-0eG9jLNXbL05XO19jt_ZCIcZ99W4IetBY66EGEHjjogYMeqDkg9MBBDyL0YD0ADwLwNqCZQIAdRNhBhB2sO9i8Bg-5jQfs-N3bo91xEgg9Eo16f4paINcjValClUOri7ROjSk4jsnMlrXicmSs4eg1GlkWdaWt1blFD9SK3ORZofhDdmPSTsxjBkQQU1YZLpbWqGCsNLwq6yoVSkkzFOIJe-S_5NmF79pyFr_x09-OPGOrCwQ-ZzctqgnzAn3OqXrpxPkDpKiCCw
link.rule.ids 786
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Accreditation+of+automated+complete+blood+count+by+the+LH750+Analyzer+%28Beckman+Coulter%29+in+Georges+Pompidou+Hospital+%28Paris%2C+France%29&rft.jtitle=Annales+de+biologie+clinique+%28Paris%29&rft.au=Robinet%2C+Sylvain&rft.au=Lemaire%2C+Pierre&rft.au=Louis%2C+Gauthier&rft.au=Vieillefond%2C+Vincent&rft.date=2013-11-01&rft.eissn=1950-6112&rft.volume=71&rft.issue=6&rft.spage=717&rft_id=info:doi/10.1684%2Fabc.2013.0892&rft_id=info%3Apmid%2F24342794&rft_id=info%3Apmid%2F24342794&rft.externalDocID=24342794