Development of Program for Relative Biological Effectiveness (RBE) Analysis of Particle Beam Therapy
Relative biological effectiveness (RBE) of particle beam needs to be evaluated at particle beam therapy centers before the clinical application of the particle beam. However, since RBE analysis is implemented manually, it is useful to have a tool that can easily and effectively handle the data of ex...
Saved in:
Published in | Progress in Medical Physics Vol. 28; no. 1; pp. 11 - 15 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
한국의학물리학회
01.03.2017
|
Subjects | |
Online Access | Get full text |
ISSN | 1226-5829 2508-4445 2288-9620 2508-4453 |
DOI | 10.14316/pmp.2017.28.1.11 |
Cover
Abstract | Relative biological effectiveness (RBE) of particle beam needs to be evaluated at particle beam therapy centers before the clinical application of the particle beam. However, since RBE analysis is implemented manually, it is useful to have a tool that can easily and effectively handle the data of experiments to generate cell survival curve and to analyze RBE simultaneously. In this work, the development of a program for RBE analysis of particle beam therapy was presented. This RBE analysis program was developed to include two parts; fitting the cell survival curves to linear-quadratic model and calculating the RBE values at a certain endpoint using fitting results. This program was also developed to simultaneously compare and analyze the template results that stored experiment data with photon and particle beam irradiations. The results of the cell survival curve obtained by each irradiation can be analyzed by the user on a desired data after reading the template stored in the easy-to-use excel file. The analysis results include the cell survival curves with error range, which are appeared in the screen and the α and β parameters of linear-quadratic model with 95% confidence intervals, RBE values, and R2 values to evaluate goodness-of-fit of survival curves to model, which are stored in a text cvs file. This software can generate cell survival curve, fit to model, and calculate RBE all at once with raw experiment data, so it helps users to save time for data handling and to reduce the possibility of making error on analysis. As a coming plan, we will create a user-friendly graphical user interface to present the results more intuitively. KCI Citation Count: 0 |
---|---|
AbstractList | Relative biological effectiveness (RBE) of particle beam needs to be evaluated at particle beam therapy centers before the clinical application of the particle beam. However, since RBE analysis is implemented manually, it is useful to have a tool that can easily and effectively handle the data of experiments to generate cell survival curve and to analyze RBE simultaneously. In this work, the development of a program for RBE analysis of particle beam therapy was presented. This RBE analysis program was developed to include two parts; fitting the cell survival curves to linear-quadratic model and calculating the RBE values at a certain endpoint using fitting results. This program was also developed to simultaneously compare and analyze the template results that stored experiment data with photon and particle beam irradiations. The results of the cell survival curve obtained by each irradiation can be analyzed by the user on a desired data after reading the template stored in the easy-to-use excel file. The analysis results include the cell survival curves with error range, which are appeared in the screen and the α and β parameters of linear-quadratic model with 95% confidence intervals, RBE values, and R2 values to evaluate goodness-of-fit of survival curves to model, which are stored in a text cvs file. This software can generate cell survival curve, fit to model, and calculate RBE all at once with raw experiment data, so it helps users to save time for data handling and to reduce the possibility of making error on analysis. As a coming plan, we will create a user-friendly graphical user interface to present the results more intuitively. KCI Citation Count: 0 |
Author | Choi, Changhoon Ahn, Sang Hee Park, Sohee Chung, Yoonsun |
Author_xml | – sequence: 1 givenname: Yoonsun surname: Chung fullname: Chung, Yoonsun organization: Department of Radiation Oncology, Samsung Medical Center, Seoul, Korea – sequence: 2 givenname: Sang Hee surname: Ahn fullname: Ahn, Sang Hee organization: Department of Health Sciences and Technology, Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, Seoul, Korea – sequence: 3 givenname: Changhoon surname: Choi fullname: Choi, Changhoon organization: Department of Radiation Oncology, Samsung Medical Center, Seoul, Korea – sequence: 4 givenname: Sohee surname: Park fullname: Park, Sohee organization: Department of Radiation Oncology, Samsung Medical Center, Seoul, Korea |
BackLink | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002556608$$DAccess content in National Research Foundation of Korea (NRF) |
BookMark | eNp9kDFvwjAUhK2KSqWUH9AtYxmS5jnEdkagtEVCaoXobL04NrUIcWRHSPz7BujUodNJp_tO7909GTSu0YQ8QprANAP23B7ahKbAEyoSSABuyJBSIeKC0XRAhkApi3NBizsyDsGWKbBc8EyIIale9FHXrj3opouciT6923k8RMb5aKNr7OxRR3PrarezCutoaYxWZ7PRIURPm_lyEs0arE_BhguPvrOq7hndt2y_tcf29EBuDdZBj391RL5el9vFe7z-eFstZutYAeMQl1mR5RyRVbliGSpE1V-pUlMwjgWlpSmRFbyiFAwUmhlj-JRykedllRfTKhuRybW38UbulZUO7UV3Tu69nG22K8l4KlJK-yy_ZpV3IXhtpLJd_65rOo-2lpDKy7ay31aet5VUSJAAPQl_yNbbA_rTP8wPb31_Tw |
CitedBy_id | crossref_primary_10_1371_journal_pone_0218049 crossref_primary_10_3390_ijms20194943 |
Cites_doi | 10.1667/RR2839.1 10.1088/0031-9155/55/22/008 10.1088/1361-6560/62/3/890 10.3857/roj.2012.30.1.1 10.1016/j.ijrobp.2010.08.010 10.1088/0031-9155/60/21/8399 10.1269/jrr.42.79 10.1088/0031-9155/57/20/6671 10.1088/0031-9155/59/22/R419 10.1080/0284186X.2016.1250947 |
ContentType | Journal Article |
DBID | AAYXX CITATION ACYCR |
DOI | 10.14316/pmp.2017.28.1.11 |
DatabaseName | CrossRef Korean Citation Index |
DatabaseTitle | CrossRef |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
EISSN | 2288-9620 2508-4453 |
EndPage | 15 |
ExternalDocumentID | oai_kci_go_kr_ARTI_6708022 10_14316_pmp_2017_28_1_11 |
GroupedDBID | AAYXX ALMA_UNASSIGNED_HOLDINGS CITATION M~E ACYCR |
ID | FETCH-LOGICAL-c1671-b39357aa6d5c63acaac873c0f967a922bfba697d221f19e6fff7427855bd594d3 |
ISSN | 1226-5829 2508-4445 |
IngestDate | Tue Nov 21 21:39:38 EST 2023 Thu Apr 24 23:10:30 EDT 2025 Tue Jul 01 03:43:40 EDT 2025 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c1671-b39357aa6d5c63acaac873c0f967a922bfba697d221f19e6fff7427855bd594d3 |
Notes | http://www.progmedphys.org/journal/view.html?uid=781&sort=&scale=&key=year&keyword=&s_v=28&s_n=1&pn=vol&year=2017&vmd=Full |
OpenAccessLink | http://synapse.koreamed.org/Synapse/Data/PDFData/2129PMP/pmp-28-11.pdf |
PageCount | 5 |
ParticipantIDs | nrf_kci_oai_kci_go_kr_ARTI_6708022 crossref_citationtrail_10_14316_pmp_2017_28_1_11 crossref_primary_10_14316_pmp_2017_28_1_11 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2017-03 |
PublicationDateYYYYMMDD | 2017-03-01 |
PublicationDate_xml | – month: 03 year: 2017 text: 2017-03 |
PublicationDecade | 2010 |
PublicationTitle | Progress in Medical Physics |
PublicationYear | 2017 |
Publisher | 한국의학물리학회 |
Publisher_xml | – name: 한국의학물리학회 |
References | Girdhani (10.14316/pmp.2017.28.1.11_ref6) 2013; 179 Paganetti (10.14316/pmp.2017.28.1.11_ref7) 2014; 59 McNamara (10.14316/pmp.2017.28.1.11_ref8) 2015; 60 Kim (10.14316/pmp.2017.28.1.11_ref12) 2011; 79 Choi (10.14316/pmp.2017.28.1.11_ref1) 2012; 30 Ando (10.14316/pmp.2017.28.1.11_ref3) 2001; 42 Fokas (10.14316/pmp.2017.28.1.11_ref2) 2009; 1796 Inaniwa (10.14316/pmp.2017.28.1.11_ref9) 2010; 55 Hall (10.14316/pmp.2017.28.1.11_ref11) 2012 Butterworth (10.14316/pmp.2017.28.1.11_ref4) 2012; 57 Saager (10.14316/pmp.2017.28.1.11_ref10) 2016; 55 Grun (10.14316/pmp.2017.28.1.11_ref5) 2017; 62 |
References_xml | – volume: 179 start-page: 257 year: 2013 ident: 10.14316/pmp.2017.28.1.11_ref6 publication-title: Radiat Res doi: 10.1667/RR2839.1 – volume: 55 start-page: 6721 year: 2010 ident: 10.14316/pmp.2017.28.1.11_ref9 publication-title: Phys Med Biol doi: 10.1088/0031-9155/55/22/008 – volume: 62 start-page: 890 year: 2017 ident: 10.14316/pmp.2017.28.1.11_ref5 publication-title: Phys Med Biol doi: 10.1088/1361-6560/62/3/890 – volume: 30 start-page: 1 year: 2012 ident: 10.14316/pmp.2017.28.1.11_ref1 publication-title: Radiat Oncol J doi: 10.3857/roj.2012.30.1.1 – volume: 1796 start-page: 216 year: 2009 ident: 10.14316/pmp.2017.28.1.11_ref2 publication-title: Biochim Biophys Acta – volume-title: Radiobiology for the radiologist year: 2012 ident: 10.14316/pmp.2017.28.1.11_ref11 – volume: 79 start-page: 559 year: 2011 ident: 10.14316/pmp.2017.28.1.11_ref12 publication-title: Int J Radiat Oncol Biol Phys doi: 10.1016/j.ijrobp.2010.08.010 – volume: 60 start-page: 8399 year: 2015 ident: 10.14316/pmp.2017.28.1.11_ref8 publication-title: Phys Med Biol doi: 10.1088/0031-9155/60/21/8399 – volume: 42 start-page: 79 year: 2001 ident: 10.14316/pmp.2017.28.1.11_ref3 publication-title: J Radiat Res doi: 10.1269/jrr.42.79 – volume: 57 start-page: 6671 year: 2012 ident: 10.14316/pmp.2017.28.1.11_ref4 publication-title: Phys Med Biol doi: 10.1088/0031-9155/57/20/6671 – volume: 59 start-page: R419 year: 2014 ident: 10.14316/pmp.2017.28.1.11_ref7 publication-title: Phys Med Biol doi: 10.1088/0031-9155/59/22/R419 – volume: 55 start-page: 1512 year: 2016 ident: 10.14316/pmp.2017.28.1.11_ref10 publication-title: Acta Oncol doi: 10.1080/0284186X.2016.1250947 |
SSID | ssib016587388 ssib044763779 ssib036278804 ssib005568776 ssib011906891 ssib044757084 |
Score | 1.9818603 |
Snippet | Relative biological effectiveness (RBE) of particle beam needs to be evaluated at particle beam therapy centers before the clinical application of the particle... |
SourceID | nrf crossref |
SourceType | Open Website Enrichment Source Index Database |
StartPage | 11 |
SubjectTerms | 방사선과학 |
Title | Development of Program for Relative Biological Effectiveness (RBE) Analysis of Particle Beam Therapy |
URI | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002556608 |
Volume | 28 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | 의학물리, 2017, 28(1), , pp.11-15 |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LbxMxELZCuXBBIECUlyzEgYc2rJ1de_fYVkEFqagSqSgny88kKuyiKOXAgV_Aj2bsddabFhDl4kSW7U08345n7JnPCD0j1nOGKJIpZ1RWUM0zVRCTGcKJAgeAyJBIe_SeHZ4U707L09Ho5yBq6Xytxvr7b_NK_keqUAdy9VmyV5BsPyhUwHeQL5QgYSj_ScaDiJ8Qy9bFWoXIwS7I7ZuNl00GUXRMxRv15vcO9qd-V2BITHIcH_Nq38JIswHnQLRgw0N8_2U65QlhpClq_mARNcin1id49vDbW3SbrbKZw3JnU_N2GU_-m_miTXEBxzGO-0O7iK3j9gQseX18VtSoYN9lZRW3NWyooxQEWTOaD9UwrS7BrdOpnTK-pOp9Dr-_oPiLZx0lfEyrMRlHxb1Fq31hueuDEL374wcRMITwQwhaCSJ8ovh1ynk49C-zj0lblaziyXgjYEqxKjENEbDl-CSRv4FlwEE59tquKECV80D-2M9JPGb3v-L1xT-yZShda1ZuYPfMbqGb0WHBex0sbqORbe4gM0Aebh2OyMOAPLxBHk7Iw1vIw88Bdy_wBnWhf0Qd9qjDEXV30cmb6ezgMIv3dWSaMA6vu0_z5lIyU2o2kVpKDTOic1czLmtKlVOS1dxQShypLXPOcX_TS1kqU9aFmdxDO03b2PsI5w68Pi11wcGlYLVRlS3dhMnKmYppm--ifDM5Qkcye3-nymfxR6nuopd9l68dk8vfGj-FGRdneik8_7r_nLfibCXAy3wrGA8Z6g-uMuJDdCO9Ho_Qznp1bh-DPbtWTwLMoDz6Mf0FTqyX5Q |
linkProvider | Korean Association of Medical Journal Editors |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Development+of+Program+for+Relative+Biological+Effectiveness+%28RBE%29+Analysis+of+Particle+Beam+Therapy&rft.jtitle=Progress+in+Medical+Physics&rft.au=Chung%2C+Yoonsun&rft.au=Ahn%2C+Sang+Hee&rft.au=Choi%2C+Changhoon&rft.au=Park%2C+Sohee&rft.date=2017-03-01&rft.issn=1226-5829&rft.eissn=2288-9620&rft.volume=28&rft.issue=1&rft.spage=11&rft_id=info:doi/10.14316%2Fpmp.2017.28.1.11&rft.externalDBID=n%2Fa&rft.externalDocID=10_14316_pmp_2017_28_1_11 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1226-5829&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1226-5829&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1226-5829&client=summon |