Adaption of the Quality Criteria Concept to Digital Radiology
In recent years conventional film-screen radiography has been more and more replaced by digital techniques like 'Digital Image Intensifier Radiography' and 'Digital Storage Phosphor (Selen) Radiography'. These new digital imaging methods can be used for all areas of radiography e...
Saved in:
Published in | Radiation protection dosimetry Vol. 80; no. 1-3; pp. 61 - 63 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
Oxford University Press
01.11.1998
|
Online Access | Get full text |
Cover
Loading…
Abstract | In recent years conventional film-screen radiography has been more and more replaced by digital techniques like 'Digital Image Intensifier Radiography' and 'Digital Storage Phosphor (Selen) Radiography'. These new digital imaging methods can be used for all areas of radiography except mammography. Digital radiography offers the advantage of additional diagnostic information, digital image format, lower radiation risk to the patient and a favourable cost/benefit relation. With digital techniques, dose can be varied over a wide range without losing diagnostic information. Thus, dose can be reduced in comparison to film-screen radiography. Inadequate technique can, in certain applications, however, lead to a significant increase of dose. Therefore, special reference dose values have to be established and controlled continuously. Different possibilities of pre- and post-processing make the evaluation of image quality of digital technique more complex compared with conventional film-screen radiography. New parameters like signal to noise ratio are more appropriate in assessing image quality. However, in daily routine well known parameters like spatial resolution, contrast detectability and dose can be more easily used for the assessment of image quality of the whole imaging chain including image processing and documentation. Special guidelines for digital radiography are necessary to guarantee high image quality and to avoid overexposure and misdiagnoses. These guidelines should be based on the Quality Criteria Concept of the EC. They should include criteria for the detectability of specific anatomic details, technical parameters for good radiographic technique and imaging performance and reference dose values. Assessment of image quality by suitable phantoms and constancy testing are prerequisites for quality assurance. The activities of an European quality criteria working group in the 'Concerted Action Programme' are focused on these subjects. |
---|---|
AbstractList | In recent years conventional film-screen radiography has been more and more replaced by digital techniques like 'Digital Image Intensifier Radiography' and 'Digital Storage Phosphor (Selen) Radiography'. These new digital imaging methods can be used for all areas of radiography except mammography. Digital radiography offers the advantage of additional diagnostic information, digital image format, lower radiation risk to the patient and a favourable cost/benefit relation. With digital techniques, dose can be varied over a wide range without losing diagnostic information. Thus, dose can be reduced in comparison to film-screen radiography. Inadequate technique can, in certain applications, however, lead to a significant increase of dose. Therefore, special reference dose values have to be established and controlled continuously. Different possibilities of pre- and post-processing make the evaluation of image quality of digital technique more complex compared with conventional film-screen radiography. New parameters like signal to noise ratio are more appropriate in assessing image quality. However, in daily routine well known parameters like spatial resolution, contrast detectability and dose can be more easily used for the assessment of image quality of the whole imaging chain including image processing and documentation. Special guidelines for digital radiography are necessary to guarantee high image quality and to avoid overexposure and misdiagnoses. These guidelines should be based on the Quality Criteria Concept of the EC. They should include criteria for the detectability of specific anatomic details, technical parameters for good radiographic technique and imaging performance and reference dose values. Assessment of image quality by suitable phantoms and constancy testing are prerequisites for quality assurance. The activities of an European quality criteria working group in the 'Concerted Action Programme' are focused on these subjects. |
Author | Jaschke (INVITED), W. Busch, H.P. |
Author_xml | – sequence: 1 givenname: H.P. surname: Busch fullname: Busch, H.P. – sequence: 2 givenname: W. surname: Jaschke (INVITED) fullname: Jaschke (INVITED), W. |
BookMark | eNqNkFtLwzAAhYNMcJv-h-B7Z9KkTSMIjk2dbCDOK76ELJeZWZuSZrD9ezsmgj75dJ7OdzhfD3QqXxkATjEaYMTJmd9YH_TKr0Mly2YQaj2QiKQZJQegixlNE0JR3gFdhClNCpqiI9BrmhVCKeMZ7YKLoZZ1dL6C3sL4buD9WpYubuEouGiCk3DkK2XqCKOHY7d0UZZwLrXzpV9uj8GhbXfNyXf2wdP11eNokszubm5Hw1miMM3HSZqRPC-MyRXKTK45SrVcaGO4xVRRSRfUcptxzFmBLWeM0yJjChllC0S1kaQPzvdcFXzTBGNFHdynDFuBkdiJEL9FiFaE-BbRli__lFX7Yvc5BunK_yGSPcI10Wx-xmX4EDkjLBOT1zcxnT9MX4pnIsbkC-LegNw |
CitedBy_id | crossref_primary_10_1016_j_ejmp_2008_11_002 crossref_primary_10_1093_rpd_nci728 crossref_primary_10_1259_bjr_20150430 |
ContentType | Journal Article |
DBID | BSCLL AAYXX CITATION |
DOI | 10.1093/oxfordjournals.rpd.a032543 |
DatabaseName | Istex CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1742-3406 |
EndPage | 63 |
ExternalDocumentID | 10_1093_oxfordjournals_rpd_a032543 ark_67375_HXZ_KRSKW8V3_D |
GroupedDBID | --- -E4 .2P .GJ .HR .I3 .ZR 0R~ 123 1TH 4.4 48X 53G 5VS 5WA 5WD 70D 8WZ A6W AABZA AACZT AAIJN AAJKP AAMDB AAMVS AAOGV AAPNW AAPQZ AAPXW AARHZ AAUAY AAUQX AAVAP ABDFA ABDTM ABEFU ABEJV ABEUO ABGNP ABIXL ABJNI ABKDP ABNGD ABNHQ ABNKS ABPQP ABPTD ABQLI ABQNK ABVGC ABWST ABXVV ABZBJ ACGFS ACUFI ACUKT ACUTO ACUXJ ACYHN ACYTK ADBBV ADEYI ADEZT ADGZP ADHKW ADHZD ADIPN ADMLS ADNBA ADOCK ADQBN ADRDM ADRTK ADVEK ADYJX ADYVW ADZXQ AECKG AEGPL AEJOX AEKKA AEKSI AEMDU AEMQT AENEX AENZO AEPUE AETBJ AFFZL AFIYH AFOFC AFXAL AGINJ AGKEF AGORE AGQPQ AGQXC AGSYK AGUTN AHMMS AHXPO AIJHB AJBYB AJEEA AJEUX AJNCP AKWXX ALMA_UNASSIGNED_HOLDINGS ALTZX ALUQC ALXQX ANAKG APIBT APWMN ASPBG ATGXG AVWKF AXUDD AZFZN AZVOD BAYMD BCRHZ BEYMZ BHONS BQUQU BSCLL BTQHN BTRTY BVRKM CDBKE CS3 CZ4 DAKXR DILTD DU5 D~K EBS EE~ EJD EMOBN ENERS F5P F9B FECEO FEDTE FLIZI FLUFQ FOEOM FOTVD FQBLK GAUVT GJXCC H5~ HAR HVGLF HW0 HZ~ IOX J21 JXSIZ KAQDR KBUDW KOP KSI KSN M-Z MHKGH N9A NGC NMDNZ NOMLY NOYVH NU- NVLIB O0~ O9- OAUYM OAWHX OCZFY ODMLO OJQWA OJZSN OPAEJ OWPYF P2P PAFKI PB- PEELM Q1. Q5Y RD5 RNI RNS ROL ROX ROZ RUSNO RW1 RXO RZO SV3 TJP TJX X7H YAYTL YKOAZ YXANX ZKX ~91 AAYXX CITATION |
ID | FETCH-LOGICAL-c146D-253668ee6c05e6d902dabdee9f14c4a4b4f9f5919781f97794857c0ecf804dea3 |
ISSN | 0144-8420 |
IngestDate | Tue Jul 01 03:50:17 EDT 2025 Thu Apr 24 23:16:09 EDT 2025 Tue Aug 05 16:49:14 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1-3 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c146D-253668ee6c05e6d902dabdee9f14c4a4b4f9f5919781f97794857c0ecf804dea3 |
Notes | istex:4BFB72964C0CF01290940BAAA142E146ABF8F159 local:800061 ark:/67375/HXZ-KRSKW8V3-D PII:0144-8420 |
PageCount | 3 |
ParticipantIDs | crossref_primary_10_1093_oxfordjournals_rpd_a032543 crossref_citationtrail_10_1093_oxfordjournals_rpd_a032543 istex_primary_ark_67375_HXZ_KRSKW8V3_D |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 1900 |
PublicationDate | 1998-11-01 |
PublicationDateYYYYMMDD | 1998-11-01 |
PublicationDate_xml | – month: 11 year: 1998 text: 1998-11-01 day: 01 |
PublicationDecade | 1990 |
PublicationTitle | Radiation protection dosimetry |
PublicationTitleAlternate | Radiat Prot Dosimetry |
PublicationYear | 1998 |
Publisher | Oxford University Press |
Publisher_xml | – name: Oxford University Press |
SSID | ssj0027954 |
Score | 1.4941978 |
Snippet | In recent years conventional film-screen radiography has been more and more replaced by digital techniques like 'Digital Image Intensifier Radiography' and... |
SourceID | crossref istex |
SourceType | Enrichment Source Index Database Publisher |
StartPage | 61 |
Title | Adaption of the Quality Criteria Concept to Digital Radiology |
URI | https://api.istex.fr/ark:/67375/HXZ-KRSKW8V3-D/fulltext.pdf |
Volume | 80 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lj9MwELaglRAXxFMsL_mAuKCENHbc5FhRUMVShPbBVlwiP1cV0FRtkIBfz0zsJC0Psewliix5lHg-j8f2zDeEPAWXARY5piNjYbpxzlwkx5JHHDoI5pw0DpOT5-_E7JS_WWSLvmZrk11Sq1j_-GNeyWW0Cm2gV8yS_Q_NdkKhAd5Bv_AEDcPzQjqeGLluPT50ID0hxnes1YUUzBLz-TBsBR3M6fIc64M8P5Jm2R-lt9TcyFDQSAq8Dfhqqu3yi603OykPW184aha_j7vQGwmNPsLnLO7PEJqkulF3htAeK_Io56m_IbHeFMKmOWI8Ebu20ldd2sOEN3yeUT0sod5k_WacPXFV1SRChlHcxpu1iWXCMCe_X5Laa_hfVqouftDfnLNyX1YJssog6yoZprBxSAdkOJnO3x73m_Ai83zv4Y9bItqCvfj7l-05LUOcf992vJCTm-RG2D7QicfCLXLFrm6Ta_MQIHGHdJCglaMACRogQVtI0AAJWlc0QIJ2kLhLTl-_Onk5i0KFjEjDCjeN0owJkVsrdJJZYYokNVIZaws34ppLrrgrXFaMkNjMgaePVEBjnVjt8oQbK9k9MlhVK3ufUGZyp9TIKqnAyWQy51JhYauU6bERTByQoh2CUgf6eKxi8rn8tzIOCOv6rj2JyoV6PWtGuusiN58wDHGclbPFx_Lw6PjwLP_AyumDS4l_SK73U-ERGdSbr_YxOJi1ehIw8xMvSIRT |
linkProvider | EBSCOhost |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Adaption+of+the+Quality+Criteria+Concept+to+Digital+Radiology&rft.jtitle=Radiation+protection+dosimetry&rft.au=Busch%2C+H.P.&rft.au=Jaschke%2C+W.&rft.date=1998-11-01&rft.issn=0144-8420&rft.eissn=1742-3406&rft.volume=80&rft.issue=1&rft.spage=61&rft.epage=63&rft_id=info:doi/10.1093%2Foxfordjournals.rpd.a032543&rft.externalDBID=n%2Fa&rft.externalDocID=10_1093_oxfordjournals_rpd_a032543 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0144-8420&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0144-8420&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0144-8420&client=summon |