Measurement of internal pressure and air flow during colonoscopy
Appropriate adjustment of the air volume is an important for performing endoscopy. However, Novice is often confused to adjust the appropriate air volume for performing endoscopy because air volume is subjective. If the adjustment can be assessed objectively, it will be possible to instruct the adju...
Saved in:
Published in | Progress of Digestive Endoscopy Vol. 102; no. 1; pp. 23 - 26 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English Japanese |
Published |
Japan Gastroenterological Endoscopy Society Kanto Chapter
30.06.2023
|
Online Access | Get full text |
ISSN | 1348-9844 2187-4999 |
DOI | 10.11641/pde.102.1_23 |
Cover
Loading…
Abstract | Appropriate adjustment of the air volume is an important for performing endoscopy. However, Novice is often confused to adjust the appropriate air volume for performing endoscopy because air volume is subjective. If the adjustment can be assessed objectively, it will be possible to instruct the adjustment objectively to the novice. In this study, we tried to measure internal pressure in colon and flow volume inflated through endoscopy using an industrial pressure sensor and a flow sensor. We performed colonoscopy with controlling air volume while referring the internal pressure and flow volume displayed on the monitor. We conformed that the internal pressure changed directly according to flow air volume in colonoscopy insertion and removal. We successfully measured and displayed the internal pressure and flow volume during colonoscopy. The study has also limitation that number of subject is small and its clinical impact are not investigated. We would like to verify the clinical impact with collecting further data in the future. |
---|---|
AbstractList | Appropriate adjustment of the air volume is an important for performing endoscopy. However, Novice is often confused to adjust the appropriate air volume for performing endoscopy because air volume is subjective. If the adjustment can be assessed objectively, it will be possible to instruct the adjustment objectively to the novice. In this study, we tried to measure internal pressure in colon and flow volume inflated through endoscopy using an industrial pressure sensor and a flow sensor. We performed colonoscopy with controlling air volume while referring the internal pressure and flow volume displayed on the monitor. We conformed that the internal pressure changed directly according to flow air volume in colonoscopy insertion and removal. We successfully measured and displayed the internal pressure and flow volume during colonoscopy. The study has also limitation that number of subject is small and its clinical impact are not investigated. We would like to verify the clinical impact with collecting further data in the future. |
Author | Mochida, Kentaro Ishibashi, Fumiaki Nagai, Mizuki Morishita, Tetsuo Suzuki, Sho |
Author_xml | – sequence: 1 fullname: Ishibashi, Fumiaki organization: Department of Gastroenterology, International University of Heath and Welfare Ichikawa Hospital – sequence: 1 fullname: Mochida, Kentaro organization: Department of Gastroenterology, International University of Heath and Welfare Ichikawa Hospital – sequence: 1 fullname: Morishita, Tetsuo organization: Department of Gastroenterology, International University of Heath and Welfare Ichikawa Hospital – sequence: 1 fullname: Nagai, Mizuki organization: Department of Gastroenterology, International University of Heath and Welfare Ichikawa Hospital – sequence: 1 fullname: Suzuki, Sho organization: Department of Gastroenterology, International University of Heath and Welfare Ichikawa Hospital |
BookMark | eNpNkEtLAzEUhYNUsNYu3ecPTM1zJtmIUnxBxY2uQya5qSPTZEimSP-9rZXi5h4u5-Msvks0iSkCQteULCitBb0ZPCwoYQtqGD9DU0ZVUwmt9QRNKReq0kqICzQvpWsJkYI1suFTdPcKtmwzbCCOOAXcxRFytD0eMpRDgW302HYZhz59Y7_NXVxjl_oUU3Fp2F2h82D7AvO_nKGPx4f35XO1ent6Wd6vKkc545VtgrRBMSeFd0LW1HKifCCgmedaBxEok0G1gdRENa13tZM1QKtBN0wwy2eoOu66nErJEMyQu43NO0OJ-TVg9gb2DzMHA3v-9sh_ldGu4UTbPHauh3_w4TJ-KtynzQYi_wGw9WgN |
Cites_doi | 10.1055/a-1790-6141 |
ContentType | Journal Article |
Copyright | 2023 Japan Gastroenterological Endoscopy Society Kanto Chapter |
Copyright_xml | – notice: 2023 Japan Gastroenterological Endoscopy Society Kanto Chapter |
DBID | AAYXX CITATION |
DOI | 10.11641/pde.102.1_23 |
DatabaseName | CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
EISSN | 2187-4999 |
EndPage | 26 |
ExternalDocumentID | 10_11641_pde_102_1_23 article_pde_102_1_102_23_article_char_en |
GroupedDBID | ALMA_UNASSIGNED_HOLDINGS JMI JSF JSH KQ8 MOJWN RJT RZJ X7N AAYXX CITATION |
ID | FETCH-LOGICAL-c1323-a7f5af82c54dc4561a308df0e92d399f4f125f8bf06087bdc6c56eeb9e97242a3 |
ISSN | 1348-9844 |
IngestDate | Tue Jul 01 00:46:19 EDT 2025 Wed Sep 03 06:30:29 EDT 2025 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | true |
Issue | 1 |
Language | English Japanese |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c1323-a7f5af82c54dc4561a308df0e92d399f4f125f8bf06087bdc6c56eeb9e97242a3 |
OpenAccessLink | https://doi.org/10.11641/pde.102.1_23 |
PageCount | 4 |
ParticipantIDs | crossref_primary_10_11641_pde_102_1_23 jstage_primary_article_pde_102_1_102_23_article_char_en |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2023/06/30 2023-6-30 |
PublicationDateYYYYMMDD | 2023-06-30 |
PublicationDate_xml | – month: 06 year: 2023 text: 2023/06/30 day: 30 |
PublicationDecade | 2020 |
PublicationTitle | Progress of Digestive Endoscopy |
PublicationTitleAlternate | Prog. dig. Endosc |
PublicationYear | 2023 |
Publisher | Japan Gastroenterological Endoscopy Society Kanto Chapter |
Publisher_xml | – name: Japan Gastroenterological Endoscopy Society Kanto Chapter |
References | 1 2 3 |
References_xml | – ident: 2 – ident: 1 doi: 10.1055/a-1790-6141 – ident: 3 |
SSID | ssib005427573 ssj0002020061 ssib029851964 ssib043658157 ssib043658158 |
Score | 2.2246184 |
Snippet | Appropriate adjustment of the air volume is an important for performing endoscopy. However, Novice is often confused to adjust the appropriate air volume for... |
SourceID | crossref jstage |
SourceType | Index Database Publisher |
StartPage | 23 |
Title | Measurement of internal pressure and air flow during colonoscopy |
URI | https://www.jstage.jst.go.jp/article/pde/102/1/102_23/_article/-char/en |
Volume | 102 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | Progress of Digestive Endoscopy, 2023/06/30, Vol.102(1), pp.23-26 |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3Pb9MwFLbK4MAFgQCxjSEfJi6oJbETJ7kxIaaJqQjEJu0WOf5BM0EyVa2QduBv5z07Tt1th4FUWZFru3Xel5fPz-89E3JoKqaZkHYqKzTdWIZXBWAZyEBlhEgal8R1_kWcnGefL_KLyeRPHF2yambq-s64kv-RKtSBXDFK9h8kOw4KFXAN8oUSJAzlvWQ83xj4QuoHxy6dc2vYGZDt8p392f8OEYmYprrrMRpla0f3KzpqodqDgbTbdUKfItNp3xSZKMbbRJaDea8WrZZDdM9KLvvNDtP12h-H_X3Rb8C3aBs8usnx5fWvFrjraIqWP_yx2PMWe8amCMaD39yoPXkG2rP0CR1nxtUBhSimuKzaUrkJu4WtQYHy6FXsY-lvK3mRoZa_0gYTT8zSOnSKk2nfeMmNrodu0QMD1NC9hu41dn9AHrKicNv8p9_K0UYHc0SK59bsw8xCmlYY4X38B7ZozaNLYPbBK9ARlbOn5MmwwqBHHi7PyMR0z8mHCCq0tzRAhQaoUIAKBahQhAr1UKERVF6Q8-NPZx9PpsPhGVOVchCNLGwubclUnmmFLFnypNQ2wYcTSKnNLFBbWzY2EUlZNFoJlQtjmspUBdA2yV-Sna7vzCtCK14p-KhUpjASB4qbK5tqpYRkXFb5Lnkb5l5f-Rwp9Z23eZcU_s6MzYZHJ2qFJePjFxh7CI_63n1_Yp883iDzNdlZLdfmAGjjqnnjZPsXFF1vHA |
linkProvider | Colorado Alliance of Research Libraries |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Measurement+of+internal+pressure+and+air+flow+during+colonoscopy&rft.jtitle=Progress+of+digestive+endoscopy+%282000%29&rft.au=Mochida%2C+Kentaro&rft.au=Suzuki%2C+Sho&rft.au=Ishibashi%2C+Fumiaki&rft.au=Nagai%2C+Mizuki&rft.date=2023-06-30&rft.issn=1348-9844&rft.eissn=2187-4999&rft.volume=102&rft.issue=1&rft.spage=23&rft.epage=26&rft_id=info:doi/10.11641%2Fpde.102.1_23&rft.externalDBID=n%2Fa&rft.externalDocID=10_11641_pde_102_1_23 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1348-9844&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1348-9844&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1348-9844&client=summon |