Self-navigated MRI 3D whole heart sequence for non-enhanced aortic root measurement in transcatheter aortic valve intervention: comparison to cardiac CT

Abstract Purpose To evaluate image quality, inter-observer reliability and diagnostic accuracy of self-navigated noncontrast 3D whole-heart magnetic resonance angiography (MRA) for transcatheter aortic valve intervention (TAVI) evaluation in comparison to standardized contrast-enhanced computed tomo...

Full description

Saved in:
Bibliographic Details
Published inEuropean heart journal Vol. 41; no. Supplement_2
Main Authors Holzknecht, M, Pamminger, M, Tiller, C, Kranewitter, C, Kremser, C, Reindl, M, Reinstadler, S.J, Reiter, G, Piccini, D, Klug, G, Bauer, A, Metzler, B, Mayr, A
Format Journal Article
LanguageEnglish
Published 01.11.2020
Online AccessGet full text

Cover

Loading…
Abstract Abstract Purpose To evaluate image quality, inter-observer reliability and diagnostic accuracy of self-navigated noncontrast 3D whole-heart magnetic resonance angiography (MRA) for transcatheter aortic valve intervention (TAVI) evaluation in comparison to standardized contrast-enhanced computed tomography angiography (CTA). Methods Whole-heart 1.5 T MRA was performed in 33 patients (aged 84 years [IQR 79–86], 48% male) for aortic root sizing and measurements of coronary ostia heights. A subgroup of 18 (55%) patients underwent additional CTA as gold standard for TAVI measurements. Image quality was assessed by a 4-point Likert scale, continuous MRA and CTA measurements were compared with regression and Bland-Altman analysis, valve sizing by kappa statistics. Results Median image quality of MRA as rated by two observers according was 1.5 [IQR 1.5–2.5]. In 4 patients (12%) one coronary ostium each (right coronary artery 3, left main artery 1) was not clearly definable on MRA. Inter-observer correlation was substantial to excellent (r=0.61 to 0.92) with a bias of 19 mm2 for annulus area (lower limit of agreement −59 mm2, upper limit of agreement 98 mm2; p=0.009). Aortic root and ostia height measurements by MRA and CTA showed substantial to excellent correlation (r=0.65 to 0.90) with no significant bias (all p≥0.333). Mean annulus area for MRA was 414±71 mm2 and for CTA 422±80 mm2 (r=0.9) with a bias of −8 mm2 (lower limit of agreement −79 mm2, upper limit of agreement −62 mm2; p=0.333). Regarding prosthetic valve sizing there was complete consistency between MRA and CTA-based decisions (κ=1). Conclusion Self-navigated noncontrast 3D whole-heart MRA enables reliable aortic root TAVI measurements without significant difference to standardized CTA. Prosthesis sizing by MRA measurements would completely match to CTA-based choice. However, in some cases coronary ostia may be difficult to define. Funding Acknowledgement Type of funding source: None
AbstractList Abstract Purpose To evaluate image quality, inter-observer reliability and diagnostic accuracy of self-navigated noncontrast 3D whole-heart magnetic resonance angiography (MRA) for transcatheter aortic valve intervention (TAVI) evaluation in comparison to standardized contrast-enhanced computed tomography angiography (CTA). Methods Whole-heart 1.5 T MRA was performed in 33 patients (aged 84 years [IQR 79–86], 48% male) for aortic root sizing and measurements of coronary ostia heights. A subgroup of 18 (55%) patients underwent additional CTA as gold standard for TAVI measurements. Image quality was assessed by a 4-point Likert scale, continuous MRA and CTA measurements were compared with regression and Bland-Altman analysis, valve sizing by kappa statistics. Results Median image quality of MRA as rated by two observers according was 1.5 [IQR 1.5–2.5]. In 4 patients (12%) one coronary ostium each (right coronary artery 3, left main artery 1) was not clearly definable on MRA. Inter-observer correlation was substantial to excellent (r=0.61 to 0.92) with a bias of 19 mm2 for annulus area (lower limit of agreement −59 mm2, upper limit of agreement 98 mm2; p=0.009). Aortic root and ostia height measurements by MRA and CTA showed substantial to excellent correlation (r=0.65 to 0.90) with no significant bias (all p≥0.333). Mean annulus area for MRA was 414±71 mm2 and for CTA 422±80 mm2 (r=0.9) with a bias of −8 mm2 (lower limit of agreement −79 mm2, upper limit of agreement −62 mm2; p=0.333). Regarding prosthetic valve sizing there was complete consistency between MRA and CTA-based decisions (κ=1). Conclusion Self-navigated noncontrast 3D whole-heart MRA enables reliable aortic root TAVI measurements without significant difference to standardized CTA. Prosthesis sizing by MRA measurements would completely match to CTA-based choice. However, in some cases coronary ostia may be difficult to define. Funding Acknowledgement Type of funding source: None
Author Reindl, M
Kremser, C
Mayr, A
Piccini, D
Kranewitter, C
Reiter, G
Tiller, C
Metzler, B
Pamminger, M
Reinstadler, S.J
Holzknecht, M
Klug, G
Bauer, A
Author_xml – sequence: 1
  givenname: M
  surname: Holzknecht
  fullname: Holzknecht, M
  organization: Medical University of Innsbruck, University Hospital for Internal Medicine III, Cardiology and Angiology, Innsbruck, Austria
– sequence: 2
  givenname: M
  surname: Pamminger
  fullname: Pamminger, M
  organization: Medical University of Innsbruck, University Hospital for Radiology, Innsbruck, Austria
– sequence: 3
  givenname: C
  surname: Tiller
  fullname: Tiller, C
  organization: Medical University of Innsbruck, University Hospital for Internal Medicine III, Cardiology and Angiology, Innsbruck, Austria
– sequence: 4
  givenname: C
  surname: Kranewitter
  fullname: Kranewitter, C
  organization: Medical University of Innsbruck, University Hospital for Radiology, Innsbruck, Austria
– sequence: 5
  givenname: C
  surname: Kremser
  fullname: Kremser, C
  organization: Medical University of Innsbruck, University Hospital for Radiology, Innsbruck, Austria
– sequence: 6
  givenname: M
  surname: Reindl
  fullname: Reindl, M
  organization: Medical University of Innsbruck, University Hospital for Internal Medicine III, Cardiology and Angiology, Innsbruck, Austria
– sequence: 7
  givenname: S.J
  surname: Reinstadler
  fullname: Reinstadler, S.J
  organization: Medical University of Innsbruck, University Hospital for Internal Medicine III, Cardiology and Angiology, Innsbruck, Austria
– sequence: 8
  givenname: G
  surname: Reiter
  fullname: Reiter, G
  organization: Research and Development, Siemens Healthcare Diagnostics GmbH, Graz, Austria
– sequence: 9
  givenname: D
  surname: Piccini
  fullname: Piccini, D
  organization: Research and Development, Siemens Healthcare Switzerland, Renens, Switzerland
– sequence: 10
  givenname: G
  surname: Klug
  fullname: Klug, G
  organization: Medical University of Innsbruck, University Hospital for Internal Medicine III, Cardiology and Angiology, Innsbruck, Austria
– sequence: 11
  givenname: A
  surname: Bauer
  fullname: Bauer, A
  organization: Medical University of Innsbruck, University Hospital for Internal Medicine III, Cardiology and Angiology, Innsbruck, Austria
– sequence: 12
  givenname: B
  surname: Metzler
  fullname: Metzler, B
  organization: Medical University of Innsbruck, University Hospital for Internal Medicine III, Cardiology and Angiology, Innsbruck, Austria
– sequence: 13
  givenname: A
  surname: Mayr
  fullname: Mayr, A
  organization: Medical University of Innsbruck, University Hospital for Radiology, Innsbruck, Austria
BookMark eNo1kE1OwzAQhS1UJNrCBVj5Ail2HLsJO1T-KhUhQZHYRRNnQlw1drHdIG7CcUn52czTzLx5I30TMrLOIiHnnM04K8QFthtthgpQZGrGBMuOyJjLNE0KlckRGTNeyESp_PWETELYMMZyxdWYfD3jtkks9OYNItb04WlJxTX9aN0WaYvgIw34vkerkTbO0-FvgraFoa8pOB-Npt65SDuEsPfYoY3UWBo92KAhthjR_xt72PY4bIdRP_iMs5dUu24H3gQ33DiqwdcGNF2sT8lxA9uAZ386JS-3N-vFfbJ6vFsurlaJ5qnMEs64FkLLLBdCpHOOlRKY5yjruWJZpZhUjKVM1pngBU9zUch5KmotmqrWBVZiStLfXO1dCB6bcudNB_6z5Kw8sC1_2JZ_bMsDW_ENdR9zRw
ContentType Journal Article
DBID AAYXX
CITATION
DOI 10.1093/ehjci/ehaa946.0304
DatabaseName CrossRef
DatabaseTitle CrossRef
DatabaseTitleList CrossRef
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1522-9645
ExternalDocumentID 10_1093_ehjci_ehaa946_0304
GroupedDBID ---
-E4
.2P
.I3
.XZ
.ZR
08P
0R~
18M
1TH
29G
2WC
4.4
482
48X
53G
5GY
5RE
5VS
5WA
5WD
70D
AABZA
AACZT
AAJKP
AAMVS
AAOGV
AAPNW
AAPQZ
AAPXW
AARHZ
AASNB
AAUAY
AAUQX
AAVAP
AAYXX
ABEUO
ABIXL
ABKDP
ABNHQ
ABNKS
ABOCM
ABPTD
ABQLI
ABQNK
ABWST
ABXVV
ABZBJ
ACGFO
ACGFS
ACPRK
ACUFI
ACUTJ
ACUTO
ACYHN
ADBBV
ADEYI
ADEZT
ADGZP
ADHKW
ADHZD
ADIPN
ADJQC
ADOCK
ADQBN
ADRIX
ADRTK
ADVEK
ADYVW
ADZXQ
AEGPL
AEGXH
AEJOX
AEKSI
AEMDU
AENEX
AENZO
AEPUE
AETBJ
AEWNT
AFFZL
AFIYH
AFOFC
AFXAL
AFXEN
AGINJ
AGKEF
AGQXC
AGSYK
AGUTN
AHMBA
AHXPO
AIAGR
AIJHB
AJEEA
ALMA_UNASSIGNED_HOLDINGS
ALUQC
APIBT
APWMN
ATGXG
AXUDD
BAWUL
BAYMD
BCGUY
BCRHZ
BEYMZ
BHONS
BTRTY
BVRKM
C45
CDBKE
CITATION
CS3
CZ4
DAKXR
DIK
DILTD
D~K
E3Z
EBS
EE~
EMOBN
ENERS
F5P
F9B
FECEO
FLUFQ
FOEOM
FOTVD
FQBLK
GAUVT
GJXCC
GX1
H13
H5~
HAR
HW0
HZ~
IOX
J21
KAQDR
KBUDW
KOP
KQ8
KSI
KSN
L7B
M-Z
M41
M49
MHKGH
ML0
N9A
NGC
NOMLY
NOYVH
NU-
O9-
OAUYM
OAWHX
OB3
OCZFY
ODMLO
OGROG
OJQWA
OJZSN
OK1
OPAEJ
OVD
OWPYF
P2P
PAFKI
PEELM
PQQKQ
Q1.
Q5Y
R44
RD5
ROL
ROX
ROZ
RUSNO
RW1
RXO
SEL
TCURE
TEORI
TJX
W8F
WOQ
X7H
YAYTL
YKOAZ
YXANX
ZKX
~91
ID FETCH-LOGICAL-c1254-101c33c548333271eb63e88e5d7604b605600205d4319128395723dc3fbdc9eb3
ISSN 0195-668X
IngestDate Thu Sep 12 18:58:08 EDT 2024
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue Supplement_2
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c1254-101c33c548333271eb63e88e5d7604b605600205d4319128395723dc3fbdc9eb3
OpenAccessLink https://academic.oup.com/eurheartj/article-pdf/41/Supplement_2/ehaa946.0304/34520704/ehaa946.0304.pdf
ParticipantIDs crossref_primary_10_1093_ehjci_ehaa946_0304
PublicationCentury 2000
PublicationDate 2020-11-01
PublicationDateYYYYMMDD 2020-11-01
PublicationDate_xml – month: 11
  year: 2020
  text: 2020-11-01
  day: 01
PublicationDecade 2020
PublicationTitle European heart journal
PublicationYear 2020
SSID ssj0008616
Score 2.3912566
Snippet Abstract Purpose To evaluate image quality, inter-observer reliability and diagnostic accuracy of self-navigated noncontrast 3D whole-heart magnetic resonance...
SourceID crossref
SourceType Aggregation Database
Title Self-navigated MRI 3D whole heart sequence for non-enhanced aortic root measurement in transcatheter aortic valve intervention: comparison to cardiac CT
Volume 41
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1ba9RAFB7WCuKLeEXrhXnwLaTd7FyS8U12lVZZEU2hbyFzWbbqZsuSttBf4i_x93nmkmRWVrC-hDAMh5k5H3Oucw5Cr0UmpKYyS7kuaEo1gXvQ5CylQtULalscK-vvmH_iRyf0wyk7HY1-RVlLF608UNc735X8D1dhDPhqX8negLM9URiAf-AvfIHD8P0nHn81PxZpU1_aMhmgOM6_HCdkllzZlrdWA9y0SZcp7bIJwdJPTbP0Mf96vXHlm9frNlkNjkKX92jll6vnaisohomw7kvjqkt0KZLWmaCGNoagxCoHN5VMy50Of7-keGf-TcT198Yo7yLo_UCf69XKeRy3Rsvh5WIvKWCx5uqsbePx4MYAmzXr3RjBsylYyrnrMwyCKdzGYCkL7utNdtc1zSJYutan7niqyU6B4ItlmeU35SCyrGtB-YGNBw8CsAv6_yEX-2xFH6cnlaNSBRqVpXEL3Z7kgtlU0tnxx14DKLhrudtvKTzWAhqHjsZhvI5IIYo0m_I-uhdMEvzW4-sBGpnmIbozD0kXj9DPbZhhgBkmM-xghh1PcQczDDDDMcywRw-2MMMRzPBZg7dg1k10MMMxzN7gAWS4XeMAMjwtH6OT9-_K6VEaGnqkCvRoCiI_U4QoMJIJIZM8M5ITUxSG6ZyPqQTL2kaJx0yDVitAcbIx5AnRiiykVsJI8gTtwR7MU4RZpnMmxnCtFGDjL0zNRFboWkkpM66VfIaS7lSrc1-3pfo7H_dvNPs5ujsg-AXaazcX5iWopq185XDwG24Klvc
link.rule.ids 315,786,790,27955,27956
linkProvider Flying Publisher
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Self-navigated+MRI+3D+whole+heart+sequence+for+non-enhanced+aortic+root+measurement+in+transcatheter+aortic+valve+intervention%3A+comparison+to+cardiac+CT&rft.jtitle=European+heart+journal&rft.au=Holzknecht%2C+M&rft.au=Pamminger%2C+M&rft.au=Tiller%2C+C&rft.au=Kranewitter%2C+C&rft.date=2020-11-01&rft.issn=0195-668X&rft.eissn=1522-9645&rft.volume=41&rft.issue=Supplement_2&rft_id=info:doi/10.1093%2Fehjci%2Fehaa946.0304&rft.externalDBID=n%2Fa&rft.externalDocID=10_1093_ehjci_ehaa946_0304
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0195-668X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0195-668X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0195-668X&client=summon