The effects of labeling gap and susceptibility artifacts in pCASL perfusion MRI

To report problems found in a patient who has implemented stent implantation and then conducted a perfusion MRI using ASL(Arterial Spin Labeling), in order to suggest a solution to them. The perfusion MRI was conducted, using pCASL among ASL methods. Data from pCASL(Pseudo Continuous Arterial Spin L...

Full description

Saved in:
Bibliographic Details
Published inJournal of the Korean Society of Radiology Vol. 9; no. 4; pp. 213 - 217
Main Author Kim, Seong-Hu
Format Journal Article
LanguageEnglish
Published 한국방사선학회 30.06.2015
Subjects
Online AccessGet full text
ISSN1976-0620
2384-0633
DOI10.7742/jksr.2015.9.4.213

Cover

Abstract To report problems found in a patient who has implemented stent implantation and then conducted a perfusion MRI using ASL(Arterial Spin Labeling), in order to suggest a solution to them. The perfusion MRI was conducted, using pCASL among ASL methods. Data from pCASL(Pseudo Continuous Arterial Spin Labeling) was acquired together with the structural image simply by changing position(labeling gap 15 mm, 170 mm) of the labeling pulse to avoid stent. Data was processed through the ASLtbx. When perfusion MRI was acquired using pCASL, it showed that the position of the conventional labeling pulse (labeling gap 24 mm) was overlapped with that of stent, which made signal intensity in right brain tissue appear as if it were void. When the labeling pulse was positioned (labeling gap 15 mm) to avoid stent, high signal intensity images were acquired. In labeling pulse (labeling gap 170 mm), the signal intensity was more reduced due to relaxation before labeled blood arrived at the imaging slice. pCASL can be stably repeated measurements because it does not use a contrast agent. And it should be selected with the appropriate image acquisition parameters for the high quality image. KCI Citation Count: 0
AbstractList To report problems found in a patient who has implemented stent implantation and then conducted a perfusion MRI using ASL(Arterial Spin Labeling), in order to suggest a solution to them. The perfusion MRI was conducted, using pCASL among ASL methods. Data from pCASL(Pseudo Continuous Arterial Spin Labeling) was acquired together with the structural image simply by changing position(labeling gap 15 mm, 170 mm) of the labeling pulse to avoid stent. Data was processed through the ASLtbx. When perfusion MRI was acquired using pCASL, it showed that the position of the conventional labeling pulse (labeling gap 24 mm) was overlapped with that of stent, which made signal intensity in right brain tissue appear as if it were void. When the labeling pulse was positioned (labeling gap 15 mm) to avoid stent, high signal intensity images were acquired. In labeling pulse (labeling gap 170 mm), the signal intensity was more reduced due to relaxation before labeled blood arrived at the imaging slice. pCASL can be stably repeated measurements because it does not use a contrast agent. And it should be selected with the appropriate image acquisition parameters for the high quality image. KCI Citation Count: 0
Author Kim, Seong-Hu
Author_xml – sequence: 1
  givenname: Seong-Hu
  surname: Kim
  fullname: Kim, Seong-Hu
BackLink https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002005394$$DAccess content in National Research Foundation of Korea (NRF)
BookMark eNotkLtOwzAYRi1UJErpA7B5ZEnwLb6MVcWlUlGlUmbrj2MX05BEdjr07WmB6XzD0TecWzTp-s4jdE9JqZRgj1-HnEpGaFWaUpSM8is0ZVyLgkjOJ2hKjZLnzcgNmucca8KlkFJpMUWb3afHPgTvxoz7gFuofRu7Pd7DgKFrcD5m54cx1rGN4wlDGmOAixw7PCwX72s8-BSOOfYdftuu7tB1gDb7-T9n6OP5abd8Ldabl9VysS4cpZoXjSLUaaald6YGxplvQAktlQuUE_DQaAFBUUYMD0J7SRpfmQogGMpMqPgMPfz9dinYg4u2h_jLfW8PyS62u5XlrKLanFX6p7rU55x8sEOK35BOlhJ76Wcv_eylnzVW2HM__gNhYmWE
Cites_doi 10.1016/j.diii.2013.06.010
10.1016/j.nicl.2013.04.014
10.3174/ajnr.A1030
10.1016/S0720-048X(99)00050-9
10.1002/mrm.21790
10.1016/j.mri.2007.07.003
10.1002/mrm.21403
10.1002/mrm.22245
ContentType Journal Article
DBID AAYXX
CITATION
ACYCR
DOI 10.7742/jksr.2015.9.4.213
DatabaseName CrossRef
Korean Citation Index
DatabaseTitle CrossRef
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
EISSN 2384-0633
EndPage 217
ExternalDocumentID oai_kci_go_kr_ARTI_325189
10_7742_jksr_2015_9_4_213
GroupedDBID .UV
AAYXX
ALMA_UNASSIGNED_HOLDINGS
CITATION
ACYCR
KROLR
ID FETCH-LOGICAL-c1183-d701c8286ec9ba232eda74867cf130aead84af712093f48e60de595aaf9129f53
ISSN 1976-0620
IngestDate Tue Nov 21 21:42:53 EST 2023
Tue Jul 01 03:09:42 EDT 2025
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed false
IsScholarly false
Issue 4
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c1183-d701c8286ec9ba232eda74867cf130aead84af712093f48e60de595aaf9129f53
Notes http://www.radlab.org/page/page_view?menu_num=75
G704-SER000000653.2015.09.04.001
OpenAccessLink http://society.kisti.re.kr/sv/SV_svpsbs03V.do?method=download&cn1=JAKO201521056137301
PageCount 5
ParticipantIDs nrf_kci_oai_kci_go_kr_ARTI_325189
crossref_primary_10_7742_jksr_2015_9_4_213
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2015-06-30
PublicationDateYYYYMMDD 2015-06-30
PublicationDate_xml – month: 06
  year: 2015
  text: 2015-06-30
  day: 30
PublicationDecade 2010
PublicationTitle Journal of the Korean Society of Radiology
PublicationYear 2015
Publisher 한국방사선학회
Publisher_xml – name: 한국방사선학회
References (BSSHB5_2015_v9n4_213_005) 2008; 26
(BSSHB5_2015_v9n4_213_004) 2013; 2
(BSSHB5_2015_v9n4_213_002) 2011; 30
(BSSHB5_2015_v9n4_213_007) 2008; 60
(BSSHB5_2015_v9n4_213_008) 2007; 58
(BSSHB5_2015_v9n4_213_010) 2010; 63
(BSSHB5_2015_v9n4_213_003) 2013; 94
(BSSHB5_2015_v9n4_213_001) 1999; 30
(BSSHB5_2015_v9n4_213_009) 2013; 24
(BSSHB5_2015_v9n4_213_006) 2008; 29
References_xml – volume: 94
  start-page: 1211
  year: 2013
  ident: BSSHB5_2015_v9n4_213_003
  publication-title: Diagnostic and Interventional Imaging
  doi: 10.1016/j.diii.2013.06.010
– volume: 2
  start-page: 630
  year: 2013
  ident: BSSHB5_2015_v9n4_213_004
  publication-title: NeuroImage Clinical
  doi: 10.1016/j.nicl.2013.04.014
– volume: 29
  start-page: 1228
  year: 2008
  ident: BSSHB5_2015_v9n4_213_006
  publication-title: AJNR Am J Neuroradiol
  doi: 10.3174/ajnr.A1030
– volume: 30
  start-page: 115
  year: 1999
  ident: BSSHB5_2015_v9n4_213_001
  publication-title: European Journal of Radiology
  doi: 10.1016/S0720-048X(99)00050-9
– volume: 30
  start-page: 1321
  year: 2011
  ident: BSSHB5_2015_v9n4_213_002
  publication-title: Journal of Cerebral Blood Flow & Metabolism
– volume: 60
  start-page: 1488
  year: 2008
  ident: BSSHB5_2015_v9n4_213_007
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.21790
– volume: 26
  start-page: 261
  year: 2008
  ident: BSSHB5_2015_v9n4_213_005
  publication-title: Magn Reson Imaging
  doi: 10.1016/j.mri.2007.07.003
– volume: 58
  start-page: 1020
  year: 2007
  ident: BSSHB5_2015_v9n4_213_008
  publication-title: Magnetic Resonance in Medicine
  doi: 10.1002/mrm.21403
– volume: 24
  start-page: 108
  year: 2013
  ident: BSSHB5_2015_v9n4_213_009
  publication-title: Korean Journal of Medical Physics
– volume: 63
  start-page: 765
  year: 2010
  ident: BSSHB5_2015_v9n4_213_010
  publication-title: Magnetic Resonance in Medicine
  doi: 10.1002/mrm.22245
SSID ssib036466784
ssib010494110
ssib051116959
ssib012146256
ssib036279067
ssib039546180
Score 1.5674062
Snippet To report problems found in a patient who has implemented stent implantation and then conducted a perfusion MRI using ASL(Arterial Spin Labeling), in order to...
SourceID nrf
crossref
SourceType Open Website
Index Database
StartPage 213
SubjectTerms 원자력공학
Title The effects of labeling gap and susceptibility artifacts in pCASL perfusion MRI
URI https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002005394
Volume 9
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
ispartofPNX 한국방사선학회논문지, 2015, 09(04), 44, pp.213-217
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV3Pb9MwFLa6ceGCQIAYMGQkfAGlJLUdx8ckC9oQBQk2aTcrvzyVSu3UH4dx4J_jH-M9p83cAdKAS2S5jtO89-X5s_P8hZBXMMgJWdZVgPExEED4gyqC56oGLKuwsaF06vrjj_HxmXh_Ls8Hgx9e1tJ6VQ3rb7_dV_IvXoU68Cvukv0Lz_adQgWUwb9wBA_D8dY-9hIywKHd7vKL8tK9FFiuly5rxSXAXqGe0QQ3MnSp43n65QOqFts1Lpi9GX8-8YkqK46YlkznrEhZJll6xIqMZSFLNStyloxYmruCYGm4baxdIWVJjo0TyTJXgJZZgo1ThYkV4FSUH01C4S1DuMto_LnrNItcX9CL8BcmIrnNottA6T__pxeTgTFB36Ou69bVAdEQUMf5Tuzl3jA-6raE3hwhgO2i4uzX6RLFYCM51EMx7M_01bhvjJI7etzTemIu5ma6MDDrODEcSGKi98idkVIuV2D8vdgGtQgFeDyOFeGX1EfXAkZAIJT2JPR5LGIgEH2Q5FqKOHJfAOwN0b2dx1t5-8uN7PCrvdnCenTp9D65t5nn0LQD7QMyaGcPyScALN0Als4t3QKWAmApAJbuApb2gKWTGXWApT1gKQD2ETl7V5zmx8Hmix5BDRNZHjQqjGoULmhrXZVA5tumVKj5WFuIFSVEtUSUVuF-bm5F0sZh00oty9Jq4KVW8sdkfzaftU8IjRulVcWBWpVg0DasYquaqrQcTq8bLQ7I660dzGUn3GJgwotGM2g0g0Yz2ggDRjsgL8FSzq1_dO_TW7R5Ru5ePwnPyf5qsW4PgbSuqhcOFD8BuAd2Rw
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=The+effects+of+labeling+gap+and+susceptibility+artifacts+in+pCASL+perfusion+MRI&rft.jtitle=%ED%95%9C%EA%B5%AD%EB%B0%A9%EC%82%AC%EC%84%A0%ED%95%99%ED%9A%8C%EB%85%BC%EB%AC%B8%EC%A7%80%2C+09%2804%29&rft.au=%EA%B9%80%EC%84%B1%ED%9B%84&rft.date=2015-06-30&rft.pub=%ED%95%9C%EA%B5%AD%EB%B0%A9%EC%82%AC%EC%84%A0%ED%95%99%ED%9A%8C&rft.issn=1976-0620&rft.eissn=2384-0633&rft.spage=213&rft.epage=217&rft_id=info:doi/10.7742%2Fjksr.2015.9.4.213&rft.externalDBID=n%2Fa&rft.externalDocID=oai_kci_go_kr_ARTI_325189
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1976-0620&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1976-0620&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1976-0620&client=summon