SU‐D‐18C‐05: Variable Bolus Arterial Spin Labeling MRI for Accurate Cerebral Blood Flow and Arterial Transit Time Mapping
Purpose: Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) maps can be calculated. Acquisition with variable post‐labeling delays (PLD) and variable TRs allows for arterial transit time (ATT) mapping and leads to more accurate CBF quant...
Saved in:
Published in | Medical physics (Lancaster) Vol. 41; no. 6Part4; p. 121 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
United States
American Association of Physicists in Medicine
01.06.2014
|
Subjects | |
Online Access | Get full text |
ISSN | 0094-2405 2473-4209 |
DOI | 10.1118/1.4887913 |
Cover
Loading…
Abstract | Purpose:
Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) maps can be calculated. Acquisition with variable post‐labeling delays (PLD) and variable TRs allows for arterial transit time (ATT) mapping and leads to more accurate CBF quantification with a scan time saving of 48%. In addition, T1 and M0 maps can be obtained without a separate scan. In order to accurately estimate ATT and T1 of brain tissue from the ASL data, variable labeling durations were invented, entitled variable‐bolus ASL.
Methods:
All images were collected on a healthy subject with a 3T Siemens Skyra scanner. Variable‐bolus Psuedo‐continuous ASL (PCASL) images were collected with 7 TI times ranging 100‐4300ms in increments of 700ms with TR ranging 1000‐5200ms. All boluses were 1600ms when the TI allowed, otherwise the bolus duration was 100ms shorter than the TI. All TI times were interleaved to reduce sensitivity to motion. Voxel‐wise T1 and M0 maps were estimated using a linear least squares fitting routine from the average singal from each TI time. Then pairwise subtraction of each label/control pair and averaging for each TI time was performed. CBF and ATT maps were created using the standard model by Buxton et al. with a nonlinear fitting routine using the T1 tissue map.
Results:
CBF maps insensitive to ATT were produced along with ATT maps. Both maps show patterns and averages consistent with literature. The T1 map also shows typical T1 contrast.
Conclusion:
It has been demonstrated that variablebolus ASL produces CBF maps free from the errors due to ATT and tissue T1 variations and provides M0, T1, and ATT maps which have potential utility. This is accomplished with a single scan in a feasible scan time (under 6 minutes) with low sensivity to motion. |
---|---|
AbstractList | Abstract only Purpose: Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) maps can be calculated. Acquisition with variable post-labeling delays (PLD) and variable TRs allows for arterial transit time (ATT) mapping and leads to more accurate CBF quantification with a scan time saving of 48%. In addition, T1 and M0 maps can be obtained without a separate scan. In order to accurately estimate ATT and T1 of brain tissue from the ASL data, variable labeling durations were invented, entitled variable-bolus ASL. Methods: All images were collected on a healthy subject with a 3T Siemens Skyra scanner. Variable-bolus Psuedo-continuous ASL (PCASL) images were collected with 7 TI times ranging 100-4300ms in increments of 700ms with TR ranging 1000-5200ms. All boluses were 1600ms when the TI allowed, otherwise the bolus duration was 100ms shorter than the TI. All TI times were interleaved to reduce sensitivity to motion. Voxel-wise T1 and M0 maps were estimated using a linear least squares fitting routine from the average singal from each TI time. Then pairwise subtraction of each label/control pair and averaging for each TI time was performed. CBF and ATT maps were created using the standard model by Buxton et al. with a nonlinear fitting routine using the T1 tissue map. Results: CBF maps insensitive to ATT were produced along with ATT maps. Both maps show patterns and averages consistent with literature. The T1 map also shows typical T1 contrast. Conclusion: It has been demonstrated that variablebolus ASL produces CBF maps free from the errors due to ATT and tissue T1 variations and provides M0, T1, and ATT maps which have potential utility. This is accomplished with a single scan in a feasible scan time (under 6 minutes) with low sensivity to motion. Purpose: Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) maps can be calculated. Acquisition with variable post‐labeling delays (PLD) and variable TRs allows for arterial transit time (ATT) mapping and leads to more accurate CBF quantification with a scan time saving of 48%. In addition, T1 and M0 maps can be obtained without a separate scan. In order to accurately estimate ATT and T1 of brain tissue from the ASL data, variable labeling durations were invented, entitled variable‐bolus ASL. Methods: All images were collected on a healthy subject with a 3T Siemens Skyra scanner. Variable‐bolus Psuedo‐continuous ASL (PCASL) images were collected with 7 TI times ranging 100‐4300ms in increments of 700ms with TR ranging 1000‐5200ms. All boluses were 1600ms when the TI allowed, otherwise the bolus duration was 100ms shorter than the TI. All TI times were interleaved to reduce sensitivity to motion. Voxel‐wise T1 and M0 maps were estimated using a linear least squares fitting routine from the average singal from each TI time. Then pairwise subtraction of each label/control pair and averaging for each TI time was performed. CBF and ATT maps were created using the standard model by Buxton et al. with a nonlinear fitting routine using the T1 tissue map. Results: CBF maps insensitive to ATT were produced along with ATT maps. Both maps show patterns and averages consistent with literature. The T1 map also shows typical T1 contrast. Conclusion: It has been demonstrated that variablebolus ASL produces CBF maps free from the errors due to ATT and tissue T1 variations and provides M0, T1, and ATT maps which have potential utility. This is accomplished with a single scan in a feasible scan time (under 6 minutes) with low sensivity to motion. |
Author | Jung, Y Johnston, M |
Author_xml | – sequence: 1 givenname: M surname: Johnston fullname: Johnston, M – sequence: 2 givenname: Y surname: Jung fullname: Jung, Y |
BackLink | https://www.osti.gov/biblio/22334007$$D View this record in Osti.gov |
BookMark | eNp10M1OwkAQB_CNwURAD77BJp48FGc_Cq03QFESiEaq12a7neKa0iW7JYSTPoLP6JNYhcSTh5lJJr_5H6ZDWpWtkJBzBj3GWHTFejKKBjETR6TN5UAEkkPcIm2AWAZcQnhCOt6_AUBfhNAm74vnr4_Pm6ZYNG46hNf0RTmjshLpyJYbT4euxmZR0sXaVHSmMixNtaTzpyktrKNDrTdO1UjH6DBzjRuV1uZ0UtotVVX-d584VXlT08SskM7VuolbnpLjQpUezw6zS5LJbTK-D2YPd9PxcBZoBiCCEEWkeZ9noYhlLIq-LHIllQgFA8YGKpYMMcacoRRFCCHXUrI8EzlwzLNMdMnFPtb62qRemxr1q7ZVhbpOORdCAgwadblX2lnvHRbp2pmVcruUQfrz3pSlh_c2NtjbrSlx9z9M54-__htZwHx1 |
ContentType | Journal Article |
Copyright | 2014 American Association of Physicists in Medicine |
Copyright_xml | – notice: 2014 American Association of Physicists in Medicine |
DBID | AAYXX CITATION OTOTI |
DOI | 10.1118/1.4887913 |
DatabaseName | CrossRef OSTI.GOV |
DatabaseTitle | CrossRef |
DatabaseTitleList | CrossRef |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine Physics |
EISSN | 2473-4209 |
EndPage | 121 |
ExternalDocumentID | 22334007 10_1118_1_4887913 MP7913 |
Genre | miscellaneous |
GroupedDBID | --- --Z -DZ .GJ 0R~ 1OB 1OC 29M 2WC 33P 36B 3O- 4.4 53G 5GY 5RE 5VS AAHHS AAHQN AAIPD AAMNL AANLZ AAQQT AASGY AAXRX AAYCA AAZKR ABCUV ABDPE ABEFU ABFTF ABJNI ABLJU ABQWH ABTAH ABXGK ACAHQ ACBEA ACCFJ ACCZN ACGFO ACGFS ACGOF ACPOU ACXBN ACXQS ADBBV ADBTR ADKYN ADOZA ADXAS ADZMN AEEZP AEGXH AEIGN AENEX AEQDE AEUYR AFBPY AFFPM AFWVQ AHBTC AIACR AIAGR AITYG AIURR AIWBW AJBDE ALMA_UNASSIGNED_HOLDINGS ALUQN ALVPJ AMYDB ASPBG BFHJK C45 CS3 DCZOG DRFUL DRMAN DRSTM DU5 EBD EBS EJD EMB EMOBN F5P HDBZQ HGLYW I-F KBYEO LATKE LEEKS LOXES LUTES LYRES MEWTI O9- OVD P2P P2W PALCI PHY RJQFR RNS ROL SAMSI SUPJJ SV3 TEORI TN5 TWZ USG WOHZO WXSBR XJT ZGI ZVN ZXP ZY4 ZZTAW AAYXX ADMLS AEYWJ AGHNM AGYGG CITATION 476 AAJUZ AAPBV ABCVL ABPTK ACSMX ADDAD AEUQT OTOTI |
ID | FETCH-LOGICAL-c1003-5e38c262b539493f64fda4a35310117a941ee9ed1e43f5052c441db3d02edbb3 |
ISSN | 0094-2405 |
IngestDate | Fri May 19 00:35:09 EDT 2023 Tue Jul 01 00:18:40 EDT 2025 Wed Jan 22 16:40:24 EST 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 6Part4 |
Language | English |
License | http://onlinelibrary.wiley.com/termsAndConditions#vor |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c1003-5e38c262b539493f64fda4a35310117a941ee9ed1e43f5052c441db3d02edbb3 |
PageCount | 1 |
ParticipantIDs | osti_scitechconnect_22334007 crossref_primary_10_1118_1_4887913 wiley_primary_10_1118_1_4887913_MP7913 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | June 2014 2014-06-00 2014-06-01 |
PublicationDateYYYYMMDD | 2014-06-01 |
PublicationDate_xml | – month: 06 year: 2014 text: June 2014 |
PublicationDecade | 2010 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Medical physics (Lancaster) |
PublicationYear | 2014 |
Publisher | American Association of Physicists in Medicine |
Publisher_xml | – name: American Association of Physicists in Medicine |
SSID | ssj0006350 |
Score | 2.0916908 |
Snippet | Purpose:
Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) maps can be calculated. Acquisition... Abstract only Purpose: Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) maps can be calculated. Acquisition... |
SourceID | osti crossref wiley |
SourceType | Open Access Repository Index Database Publisher |
StartPage | 121 |
SubjectTerms | 60 APPLIED LIFE SCIENCES ANIMAL TISSUES BLOOD FLOW BRAIN CARBON 18 ENERGY BEAM DEPOSITION Flow visualization Haemodynamics Image scanners LABELLING LASER RADIATION Magnetic resonance imaging Medical imaging NMR IMAGING Nonlinear maps Pulsed laser deposition RADIOLOGY AND NUCLEAR MEDICINE Standard Model |
Title | SU‐D‐18C‐05: Variable Bolus Arterial Spin Labeling MRI for Accurate Cerebral Blood Flow and Arterial Transit Time Mapping |
URI | https://onlinelibrary.wiley.com/doi/abs/10.1118%2F1.4887913 https://www.osti.gov/biblio/22334007 |
Volume | 41 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnZ3faxQxEMeDXFF8Ea2Kp1WCiC9L6v5I9odv16ulSleKd5X6tCSbRArlrtTtg_71ziSbva1YUV_2jnCbW_IJszPJfCeEvEqsFJVOLSsqLRnPecIUNzkrha2k5lIIjXrn-mN-eMI_nIrTzcl0Tl3Sqd32x291Jf9DFdqAK6pk_4Hs0Ck0wHfgC1cgDNe_Yrw4YfssKecsFhjZf4a41ymh9uBfv-G6u3uIaHFxtoqOpPLS8_rTe5dbOGvbK6wTEc3NJe4en0d7mMQeHZyvfZbwcL97n511Ti4S1RIrOnwdO7Vhs8evkrhlXJRWS3_ox7DS4A7jCtn6Q2NvbL6Mlx8SvkmTCia14rhF47emjWtLeZExnsbV2MzyZDSd8husNyoSkl0wKkXlJaq_FMMGZybjrnrAVgpxQTwhW7P9-mgxvHzBf_Kqo_6p-mJS0PObod9rLshkDab0emTiXIvlfXKvjwnozAN-QG6Z1Ta5U_dZD9vk9rEf2Ifk-4j4Wxp4U8ebBl4UedPAmwJvCrxp4E0Db-p4U-RNgffm_p43Rd605_2ILA_eLeeHrD88g7UJ5hsKk5VtmqdKZBWvMptzqyWXGdhcLAMoK54YUxmdGJ5ZPM2wBcdYq0zHqdFKZY_JZLVemSeEtrJQhkurtIDfiLS0lvOstbmUotBFPCUvw3A2F75ESuNDy7JJmn7Mp2QHB7oBvw6LE7eYxdV2TeA5Ja8dgJs7aOpj_Hj6536ekbubSbpDJt3llXkOXmOnXvQz5Se9zmZ6 |
linkProvider | EBSCOhost |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=SU-D-18C-05%3A+Variable+Bolus+Arterial+Spin+Labeling+MRI+for+Accurate+Cerebral+Blood+Flow+and+Arterial+Transit+Time+Mapping&rft.jtitle=Medical+physics+%28Lancaster%29&rft.au=Johnston%2C+M&rft.au=Jung%2C+Y&rft.date=2014-06-01&rft.issn=0094-2405&rft.eissn=2473-4209&rft.volume=41&rft.issue=6&rft_id=info:doi/10.1118%2F1.4887913&rft.externalDocID=22334007 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0094-2405&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0094-2405&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0094-2405&client=summon |