Agreement between spectral-domain and time-domain OCT for measuring RNFL thickness

Background/aims:To evaluate spectral-domain (SD) optical coherence tomography (OCT) reproducibility and assess the agreement between SD-OCT and Time-Domain (TD) OCT retinal nerve fibre layer (RNFL) measurements.Methods:Three Cirrus-SD-OCT scans and one Stratus-TD-OCT scan were obtained from Diagnost...

Full description

Saved in:
Bibliographic Details
Published inBritish journal of ophthalmology Vol. 93; no. 6; pp. 775 - 781
Main Authors Vizzeri, G, Weinreb, R N, Gonzalez-Garcia, A O, Bowd, C, Medeiros, F A, Sample, P A, Zangwill, L M
Format Journal Article
LanguageEnglish
Published BMA House, Tavistock Square, London, WC1H 9JR BMJ Publishing Group Ltd 01.06.2009
BMJ Publishing Group
BMJ Publishing Group LTD
Subjects
Online AccessGet full text
ISSN0007-1161
1468-2079
1468-2079
DOI10.1136/bjo.2008.150698

Cover

Loading…
Abstract Background/aims:To evaluate spectral-domain (SD) optical coherence tomography (OCT) reproducibility and assess the agreement between SD-OCT and Time-Domain (TD) OCT retinal nerve fibre layer (RNFL) measurements.Methods:Three Cirrus-SD-OCT scans and one Stratus-TD-OCT scan were obtained from Diagnostic Innovations in Glaucoma Study (DIGS) healthy participants and glaucoma patients on the same day. Repeatability was evaluated using Sw (within-subject standard deviation), CV (coefficient of variation) and ICC (intraclass correlation coefficient). Agreement was assessed using correlation and Bland–Altman plots.Results:16 healthy participants (32 eyes) and 39 patients (78 eyes) were included. SD-OCT reproducibility was excellent in both groups. The CV and ICC for Average RNFL thickness were 1.5% and 0.96, respectively, in healthy eyes and 1.6% and 0.98, respectively, in patient eyes. Correlations between RNFL parameters were strong, particularly for average RNFL thickness (R2 = 0.92 in patient eyes). Bland–Altman plots showed good agreement between instruments, with better agreement for average RNFL thickness than for sectoral RNFL parameters (for example, at 90 µm average RNFL thickness, 95% limits of agreement were −13.1 to 0.9 for healthy eyes and −16.2 to −0.3 µm for patient eyes).Conclusions:SD-OCT measurements were highly repeatable in healthy and patient eyes. Although the agreement between instruments was good, TD-OCT provided thicker RNFL measurements than SD-OCT. Measurements with these instruments should not be considered interchangeable.
AbstractList To evaluate spectral-domain (SD) optical coherence tomography (OCT) reproducibility and assess the agreement between SD-OCT and Time-Domain (TD) OCT retinal nerve fibre layer (RNFL) measurements.BACKGROUND/AIMSTo evaluate spectral-domain (SD) optical coherence tomography (OCT) reproducibility and assess the agreement between SD-OCT and Time-Domain (TD) OCT retinal nerve fibre layer (RNFL) measurements.Three Cirrus-SD-OCT scans and one Stratus-TD-OCT scan were obtained from Diagnostic Innovations in Glaucoma Study (DIGS) healthy participants and glaucoma patients on the same day. Repeatability was evaluated using Sw (within-subject standard deviation), CV (coefficient of variation) and ICC (intraclass correlation coefficient). Agreement was assessed using correlation and Bland-Altman plots.METHODSThree Cirrus-SD-OCT scans and one Stratus-TD-OCT scan were obtained from Diagnostic Innovations in Glaucoma Study (DIGS) healthy participants and glaucoma patients on the same day. Repeatability was evaluated using Sw (within-subject standard deviation), CV (coefficient of variation) and ICC (intraclass correlation coefficient). Agreement was assessed using correlation and Bland-Altman plots.16 healthy participants (32 eyes) and 39 patients (78 eyes) were included. SD-OCT reproducibility was excellent in both groups. The CV and ICC for Average RNFL thickness were 1.5% and 0.96, respectively, in healthy eyes and 1.6% and 0.98, respectively, in patient eyes. Correlations between RNFL parameters were strong, particularly for average RNFL thickness (R(2) = 0.92 in patient eyes). Bland-Altman plots showed good agreement between instruments, with better agreement for average RNFL thickness than for sectoral RNFL parameters (for example, at 90 microm average RNFL thickness, 95% limits of agreement were -13.1 to 0.9 for healthy eyes and -16.2 to -0.3 microm for patient eyes).RESULTS16 healthy participants (32 eyes) and 39 patients (78 eyes) were included. SD-OCT reproducibility was excellent in both groups. The CV and ICC for Average RNFL thickness were 1.5% and 0.96, respectively, in healthy eyes and 1.6% and 0.98, respectively, in patient eyes. Correlations between RNFL parameters were strong, particularly for average RNFL thickness (R(2) = 0.92 in patient eyes). Bland-Altman plots showed good agreement between instruments, with better agreement for average RNFL thickness than for sectoral RNFL parameters (for example, at 90 microm average RNFL thickness, 95% limits of agreement were -13.1 to 0.9 for healthy eyes and -16.2 to -0.3 microm for patient eyes).SD-OCT measurements were highly repeatable in healthy and patient eyes. Although the agreement between instruments was good, TD-OCT provided thicker RNFL measurements than SD-OCT. Measurements with these instruments should not be considered interchangeable.CONCLUSIONSSD-OCT measurements were highly repeatable in healthy and patient eyes. Although the agreement between instruments was good, TD-OCT provided thicker RNFL measurements than SD-OCT. Measurements with these instruments should not be considered interchangeable.
Background/aims: To evaluate spectral-domain (SD) optical coherence tomography (OCT) reproducibility and assess the agreement between SD-OCT and Time-Domain (TD) OCT retinal nerve fibre layer (RNFL) measurements. Methods: Three Cirrus-SD-OCT scans and one Stratus-TD-OCT scan were obtained from Diagnostic Innovations in Glaucoma Study (DIGS) healthy participants and glaucoma patients on the same day. Repeatability was evaluated using Sw (within-subject standard deviation), CV (coefficient of variation) and ICC (intraclass correlation coefficient). Agreement was assessed using correlation and Bland-Altman plots. Results: 16 healthy participants (32 eyes) and 39 patients (78 eyes) were included. SD-OCT reproducibility was excellent in both groups. The CV and ICC for Average RNFL thickness were 1.5% and 0.96, respectively, in healthy eyes and 1.6% and 0.98, respectively, in patient eyes. Correlations between RNFL parameters were strong, particularly for average RNFL thickness (R 2 â[euro]S=â[euro]S0.92 in patient eyes). Bland-Altman plots showed good agreement between instruments, with better agreement for average RNFL thickness than for sectoral RNFL parameters (for example, at 90 µm average RNFL thickness, 95% limits of agreement were -13.1 to 0.9 for healthy eyes and -16.2 to -0.3 µm for patient eyes). Conclusions: SD-OCT measurements were highly repeatable in healthy and patient eyes. Although the agreement between instruments was good, TD-OCT provided thicker RNFL measurements than SD-OCT. Measurements with these instruments should not be considered interchangeable.
To evaluate spectral-domain (SD) optical coherence tomography (OCT) reproducibility and assess the agreement between SD-OCT and Time-Domain (TD) OCT retinal nerve fibre layer (RNFL) measurements. Three Cirrus-SD-OCT scans and one Stratus-TD-OCT scan were obtained from Diagnostic Innovations in Glaucoma Study (DIGS) healthy participants and glaucoma patients on the same day. Repeatability was evaluated using Sw (within-subject standard deviation), CV (coefficient of variation) and ICC (intraclass correlation coefficient). Agreement was assessed using correlation and Bland-Altman plots. 16 healthy participants (32 eyes) and 39 patients (78 eyes) were included. SD-OCT reproducibility was excellent in both groups. The CV and ICC for Average RNFL thickness were 1.5% and 0.96, respectively, in healthy eyes and 1.6% and 0.98, respectively, in patient eyes. Correlations between RNFL parameters were strong, particularly for average RNFL thickness (R(2) = 0.92 in patient eyes). Bland-Altman plots showed good agreement between instruments, with better agreement for average RNFL thickness than for sectoral RNFL parameters (for example, at 90 microm average RNFL thickness, 95% limits of agreement were -13.1 to 0.9 for healthy eyes and -16.2 to -0.3 microm for patient eyes). SD-OCT measurements were highly repeatable in healthy and patient eyes. Although the agreement between instruments was good, TD-OCT provided thicker RNFL measurements than SD-OCT. Measurements with these instruments should not be considered interchangeable.
Background/aims: To evaluate spectral-domain (SD) optical coherence tomography (OCT) reproducibility and assess the agreement between SD-OCT and Time-Domain (TD) OCT retinal nerve fibre layer (RNFL) measurements. Methods: Three Cirrus-SD-OCT scans and one Stratus-TD-OCT scan were obtained from Diagnostic Innovations in Glaucoma Study (DIGS) healthy participants and glaucoma patients on the same day. Repeatability was evaluated using Sw (within-subject standard deviation), CV (coefficient of variation) and ICC (intraclass correlation coefficient). Agreement was assessed using correlation and Bland–Altman plots. Results: 16 healthy participants (32 eyes) and 39 patients (78 eyes) were included. SD-OCT reproducibility was excellent in both groups. The CV and ICC for Average RNFL thickness were 1.5% and 0.96, respectively, in healthy eyes and 1.6% and 0.98, respectively, in patient eyes. Correlations between RNFL parameters were strong, particularly for average RNFL thickness (R2 = 0.92 in patient eyes). Bland–Altman plots showed good agreement between instruments, with better agreement for average RNFL thickness than for sectoral RNFL parameters (for example, at 90 µm average RNFL thickness, 95% limits of agreement were −13.1 to 0.9 for healthy eyes and −16.2 to −0.3 µm for patient eyes). Conclusions: SD-OCT measurements were highly repeatable in healthy and patient eyes. Although the agreement between instruments was good, TD-OCT provided thicker RNFL measurements than SD-OCT. Measurements with these instruments should not be considered interchangeable.
Author Weinreb, R N
Bowd, C
Sample, P A
Gonzalez-Garcia, A O
Zangwill, L M
Vizzeri, G
Medeiros, F A
Author_xml – sequence: 1
  givenname: G
  surname: Vizzeri
  fullname: Vizzeri, G
  email: zangwill@glaucoma.ucsd.edu
– sequence: 2
  givenname: R N
  surname: Weinreb
  fullname: Weinreb, R N
  email: zangwill@glaucoma.ucsd.edu
– sequence: 3
  givenname: A O
  surname: Gonzalez-Garcia
  fullname: Gonzalez-Garcia, A O
  email: zangwill@glaucoma.ucsd.edu
– sequence: 4
  givenname: C
  surname: Bowd
  fullname: Bowd, C
  email: zangwill@glaucoma.ucsd.edu
– sequence: 5
  givenname: F A
  surname: Medeiros
  fullname: Medeiros, F A
  email: zangwill@glaucoma.ucsd.edu
– sequence: 6
  givenname: P A
  surname: Sample
  fullname: Sample, P A
  email: zangwill@glaucoma.ucsd.edu
– sequence: 7
  givenname: L M
  surname: Zangwill
  fullname: Zangwill, L M
  email: zangwill@glaucoma.ucsd.edu
BackLink http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=21472392$$DView record in Pascal Francis
https://www.ncbi.nlm.nih.gov/pubmed/19304586$$D View this record in MEDLINE/PubMed
BookMark eNqFkUtv1DAUhS1URB-wZociIVggZeobO3G8qVSNKEUaWlGVws66cZypp4k92Bke_x6PZjpAF7Cyrvyd43t8Dsme884Q8hzoBIBVx83CTwpK6wmUtJL1I3IAvKrzggq5Rw4opSIHqGCfHMa4SGNRgXhC9kEyysu6OiBXp_NgzGDcmDVm_G6My-LS6DFgn7d-QOsydG022sHcz5fT66zzIRsMxlWwbp5dXZzNsvHW6jtnYnxKHnfYR_Nsex6RT2dvr6fn-ezy3fvp6SxveA1jLgDalrVClrrVrZFGS-hEKSQWDHijAankTSs4cqDQIfJO12XRMpScIkV2RE42vstVM5hWpwxpa7UMdsDwU3m06u8bZ2_V3H9TjFelLFkyeL01CP7rysRRDTZq0_fojF9FVYmirqCuEvjyAbjwq-BSOAVC1JIVlMtEvfhzn90i95-dgFdbAKPGvgvotI07rgAuCiaLxB1vOB18jMF0v62oWteuUu1qXbva1J4U5QOFtiOO1q-D2_4funyjs3E0P3bPYLhL4Zko1cXNVH0RH29mH9hndZ74Nxu-GRb_XeoX_R7NfQ
CODEN BJOPAL
CitedBy_id crossref_primary_10_1097_IJG_0b013e3181ca7cbe
crossref_primary_10_1016_j_ajo_2009_10_018
crossref_primary_10_1155_2012_564627
crossref_primary_10_1038_eye_2010_178
crossref_primary_10_1097_IAE_0b013e318242b838
crossref_primary_10_1016_j_clineuro_2015_05_002
crossref_primary_10_17816_OV2014260_68
crossref_primary_10_1007_s00417_011_1811_9
crossref_primary_10_1007_s10384_010_0870_5
crossref_primary_10_2147_OPTH_S483055
crossref_primary_10_4103_0301_4738_158064
crossref_primary_10_1016_j_ajo_2010_06_041
crossref_primary_10_1097_IJG_0b013e318237c878
crossref_primary_10_1097_OPX_0000000000000452
crossref_primary_10_1097_ICU_0b013e3283437222
crossref_primary_10_1097_OPX_0b013e31822f4b82
crossref_primary_10_1016_j_optlastec_2019_105886
crossref_primary_10_1111_ceo_14044
crossref_primary_10_1007_s00417_010_1538_z
crossref_primary_10_1007_s10792_014_0028_4
crossref_primary_10_1016_j_preteyeres_2010_02_001
crossref_primary_10_1371_journal_pone_0144721
crossref_primary_10_1016_j_jfo_2014_11_022
crossref_primary_10_1016_j_ophtha_2018_08_009
crossref_primary_10_3389_fnins_2017_00494
crossref_primary_10_3109_01658107_2010_485833
crossref_primary_10_1097_IJG_0b013e3182883c29
crossref_primary_10_1097_IJG_0000000000000224
crossref_primary_10_1038_eye_2010_66
crossref_primary_10_1007_s00417_011_1808_4
crossref_primary_10_1016_j_ophtha_2010_11_029
crossref_primary_10_1371_journal_pone_0107553
crossref_primary_10_1016_j_jns_2019_116505
crossref_primary_10_1007_s10072_017_2971_0
crossref_primary_10_1016_j_ajo_2010_08_033
crossref_primary_10_1016_j_tjo_2016_01_004
crossref_primary_10_1097_IJG_0b013e3182594f42
crossref_primary_10_1111_opo_12017
crossref_primary_10_1142_S1793545818500013
crossref_primary_10_1097_IAE_0b013e31820d3feb
crossref_primary_10_5301_EJO_2011_6289
crossref_primary_10_1097_IJG_0b013e3182127ab1
crossref_primary_10_3341_jkos_2012_53_1_103
crossref_primary_10_1016_j_ophtha_2009_08_039
crossref_primary_10_36106_ijsr_0705285
crossref_primary_10_1038_eye_2013_34
crossref_primary_10_1016_j_ajo_2021_05_016
crossref_primary_10_1038_eye_2010_206
crossref_primary_10_1097_IJG_0b013e3182071cdd
crossref_primary_10_4102_aveh_v74i1_24
crossref_primary_10_1111_ceo_14341
crossref_primary_10_1212_NXI_0000000000000700
crossref_primary_10_3341_kjo_2012_26_4_271
crossref_primary_10_1016_j_bpsgos_2023_08_013
crossref_primary_10_1136_bjophthalmol_2019_314706
crossref_primary_10_1097_IJG_0000000000000363
crossref_primary_10_1111_aos_12072
crossref_primary_10_1097_WNO_0b013e3181facbbd
crossref_primary_10_1002_ana_22266
crossref_primary_10_1097_MPA_0000000000000732
crossref_primary_10_1007_s00417_009_1241_0
crossref_primary_10_1080_01658107_2022_2066699
crossref_primary_10_1097_IAE_0b013e31821a891a
crossref_primary_10_3109_02713683_2010_533807
crossref_primary_10_3928_15428877_20110224_02
crossref_primary_10_1177_1352458510365156
crossref_primary_10_1097_IJG_0000000000000280
crossref_primary_10_1109_TMI_2011_2109962
crossref_primary_10_3341_jkos_2010_51_4_524
crossref_primary_10_1016_S0365_6691_10_55002_0
crossref_primary_10_1016_j_ajo_2012_11_025
crossref_primary_10_3341_jkos_2016_57_5_786
crossref_primary_10_1055_a_1554_5663
crossref_primary_10_5301_ejo_5000822
crossref_primary_10_2174_1874364101509010078
crossref_primary_10_1007_s40135_016_0108_x
crossref_primary_10_1016_j_ophtha_2011_08_022
crossref_primary_10_1371_journal_pone_0022947
crossref_primary_10_4102_aveh_v77i1_417
crossref_primary_10_1097_OPX_0000000000000406
crossref_primary_10_1007_s00417_013_2362_z
crossref_primary_10_1167_tvst_11_6_27
crossref_primary_10_1002_acn3_674
crossref_primary_10_3341_kjo_2012_26_5_369
crossref_primary_10_17116_oftalma2019135021130
crossref_primary_10_1016_j_jfo_2020_11_009
crossref_primary_10_1007_s10384_011_0023_5
crossref_primary_10_3341_kjo_2015_29_4_263
crossref_primary_10_18231_j_ijceo_2023_007
crossref_primary_10_5402_2012_860819
crossref_primary_10_1097_ICU_0b013e3283313d4e
crossref_primary_10_1111_j_1444_0938_2012_00765_x
crossref_primary_10_1007_s00417_013_2337_0
crossref_primary_10_1111_cxo_12052
crossref_primary_10_1097_IJG_0b013e3182070cc6
crossref_primary_10_1016_j_ajo_2010_06_024
crossref_primary_10_1038_s41433_020_1020_z
crossref_primary_10_1016_j_survophthal_2016_03_006
crossref_primary_10_1097_ICO_0b013e3181e16c65
crossref_primary_10_3341_kjo_2012_26_1_32
crossref_primary_10_1097_OPX_0b013e318238c34e
crossref_primary_10_1016_S2173_5794_10_70031_1
crossref_primary_10_1017_S0033291717003555
crossref_primary_10_1136_bjophthalmol_2014_305907
crossref_primary_10_3109_08820538_2013_833270
crossref_primary_10_1016_j_ajo_2010_06_011
crossref_primary_10_1111_j_1755_3768_2010_01977_x
crossref_primary_10_1007_s40135_013_0014_4
crossref_primary_10_1016_j_ophtha_2014_01_017
ContentType Journal Article
Copyright 2009 BMJ Publishing Group Ltd
2009 INIST-CNRS
Copyright: 2009 2009 BMJ Publishing Group Ltd
Copyright_xml – notice: 2009 BMJ Publishing Group Ltd
– notice: 2009 INIST-CNRS
– notice: Copyright: 2009 2009 BMJ Publishing Group Ltd
DBID BSCLL
AAYXX
CITATION
IQODW
CGR
CUY
CVF
ECM
EIF
NPM
3V.
7X7
7XB
88E
8FI
8FJ
8FK
ABUWG
AFKRA
BENPR
BTHHO
CCPQU
FYUFA
GHDGH
K9.
M0S
M1P
PHGZM
PHGZT
PJZUB
PKEHL
PPXIY
PQEST
PQQKQ
PQUKI
7X8
5PM
DOI 10.1136/bjo.2008.150698
DatabaseName Istex
CrossRef
Pascal-Francis
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
ProQuest Central (Corporate)
Health & Medical Collection
ProQuest Central (purchase pre-March 2016)
Medical Database (Alumni Edition)
ProQuest Hospital Collection
Hospital Premium Collection (Alumni Edition)
ProQuest Central (Alumni) (purchase pre-March 2016)
ProQuest Central (Alumni)
ProQuest Central UK/Ireland
AUTh Library subscriptions: ProQuest Central
BMJ Journals
ProQuest One Community College
Health Research Premium Collection
Health Research Premium Collection (Alumni)
ProQuest Health & Medical Complete (Alumni)
ProQuest Health & Medical Collection
Medical Database
ProQuest Central Premium
ProQuest One Academic (New)
ProQuest Health & Medical Research Collection
ProQuest One Academic Middle East (New)
ProQuest One Health & Nursing
ProQuest One Academic Eastern Edition (DO NOT USE)
ProQuest One Academic
ProQuest One Academic UKI Edition
MEDLINE - Academic
PubMed Central (Full Participant titles)
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
ProQuest One Academic Middle East (New)
ProQuest One Academic Eastern Edition
ProQuest Health & Medical Complete (Alumni)
ProQuest Central (Alumni Edition)
ProQuest One Community College
ProQuest One Health & Nursing
ProQuest Hospital Collection
Health Research Premium Collection (Alumni)
ProQuest Hospital Collection (Alumni)
ProQuest Central
ProQuest Health & Medical Complete
Health Research Premium Collection
ProQuest Medical Library
ProQuest One Academic UKI Edition
Health and Medicine Complete (Alumni Edition)
BMJ Journals
Health & Medical Research Collection
ProQuest Central (New)
ProQuest One Academic
ProQuest One Academic (New)
ProQuest Medical Library (Alumni)
ProQuest Central (Alumni)
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic
ProQuest One Academic Middle East (New)
MEDLINE


Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
– sequence: 3
  dbid: BENPR
  name: ProQuest Central
  url: https://www.proquest.com/central
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1468-2079
EndPage 781
ExternalDocumentID PMC3465953
4012486581
19304586
21472392
10_1136_bjo_2008_150698
ark_67375_NVC_X7QVLM3W_H
bjophthalmol
Genre Evaluation Study
Journal Article
Research Support, N.I.H., Extramural
GeographicLocations California
GeographicLocations_xml – name: California
GrantInformation_xml – fundername: NEI NIH HHS
  grantid: R01 EY008208
– fundername: NEI NIH HHS
  grantid: EY008208
– fundername: NEI NIH HHS
  grantid: R01 EY011008
– fundername: NEI NIH HHS
  grantid: EY011008
GroupedDBID ---
-~X
.55
.GJ
.VT
0R~
18M
23N
2WC
354
39C
3O-
4.4
40O
53G
5GY
5RE
5VS
6J9
7X7
7~S
88E
8FI
8FJ
8R4
8R5
AAHLL
AAKAS
AAOJX
AAWJN
ABAAH
ABJNI
ABKDF
ABMQD
ABTFR
ABUWG
ABVAJ
ACCCW
ACGFO
ACGFS
ACGTL
ACHTP
ACMFJ
ACNCT
ACOAB
ACOFX
ACQSR
ACTZY
ADBBV
ADCEG
ADZCM
AENEX
AFKRA
AFWFF
AGQPQ
AHMBA
AHNKE
AHQMW
AJYBZ
ALIPV
ALMA_UNASSIGNED_HOLDINGS
ASPBG
AVWKF
AZFZN
BAWUL
BENPR
BLJBA
BOMFT
BPHCQ
BTFSW
BTHHO
BVXVI
C1A
C45
CAG
CCPQU
COF
CS3
CXRWF
DIK
DU5
E3Z
EBS
EJD
F5P
FYUFA
H13
HAJ
HMCUK
HYE
HZ~
IAO
IEA
IHR
IOF
ITC
J5H
KQ8
L7B
M1P
N9A
NTWIH
NXWIF
O9-
OK1
OVD
P2P
PHGZT
PQQKQ
PROAC
PSQYO
Q2X
R53
RHI
RMJ
RPM
RV8
TEORI
TR2
UAW
UKHRP
UYXKK
V24
VM9
W8F
WH7
WOQ
X7M
XOL
YFH
YQY
ZGI
3V.
BSCLL
RHF
AAYXX
ACQHZ
AERUA
CITATION
PHGZM
AAFWJ
IQODW
PJZUB
PPXIY
CGR
CUY
CVF
ECM
EIF
NPM
7XB
8FK
K9.
PKEHL
PQEST
PQUKI
7X8
PUEGO
5PM
ID FETCH-LOGICAL-b481t-711dd3d795cdcde9ec91f7579a2314bc1a094bd74a4101faa4fc852d3a940a0a3
IEDL.DBID 7X7
ISSN 0007-1161
1468-2079
IngestDate Thu Aug 21 17:54:42 EDT 2025
Thu Sep 04 17:04:06 EDT 2025
Fri Jul 25 02:33:26 EDT 2025
Mon Jul 21 05:29:11 EDT 2025
Mon Jul 21 09:17:13 EDT 2025
Tue Jul 01 01:47:44 EDT 2025
Thu Apr 24 23:07:26 EDT 2025
Wed Oct 30 09:36:59 EDT 2024
Thu Apr 24 23:05:32 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 6
Keywords Thickness
Agreement
Ophthalmology
Language English
License CC BY 4.0
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-b481t-711dd3d795cdcde9ec91f7579a2314bc1a094bd74a4101faa4fc852d3a940a0a3
Notes ark:/67375/NVC-X7QVLM3W-H
local:bjophthalmol;93/6/775
href:bjophthalmol-93-775.pdf
ArticleID:bj150698
PMID:19304586
istex:F9B6259F0E062FBA1BADDCFE4D6046AC73C0544E
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
PMID 19304586
PQID 1778932049
PQPubID 2041039
PageCount 7
ParticipantIDs pubmedcentral_primary_oai_pubmedcentral_nih_gov_3465953
proquest_miscellaneous_67286186
proquest_journals_1778932049
pubmed_primary_19304586
pascalfrancis_primary_21472392
crossref_primary_10_1136_bjo_2008_150698
crossref_citationtrail_10_1136_bjo_2008_150698
istex_primary_ark_67375_NVC_X7QVLM3W_H
bmj_primary_10_1136_bjo_2008_150698
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2009-06-01
PublicationDateYYYYMMDD 2009-06-01
PublicationDate_xml – month: 06
  year: 2009
  text: 2009-06-01
  day: 01
PublicationDecade 2000
PublicationPlace BMA House, Tavistock Square, London, WC1H 9JR
PublicationPlace_xml – name: BMA House, Tavistock Square, London, WC1H 9JR
– name: London
– name: England
PublicationTitle British journal of ophthalmology
PublicationTitleAlternate Br J Ophthalmol
PublicationYear 2009
Publisher BMJ Publishing Group Ltd
BMJ Publishing Group
BMJ Publishing Group LTD
Publisher_xml – name: BMJ Publishing Group Ltd
– name: BMJ Publishing Group
– name: BMJ Publishing Group LTD
References van Velthoven, Faber, Verbraak 2007; 26
de Boer, Cense, Hyle Park 2003; 28
Huang, Swanson, Lin 1991; 254
Bland, Altman 1999; 8
Cheung, Leung, Lin 2008; 115
Wojtkowski, Leitgeb, Kowalczyk 2002; 7
Paunescu, Schuman, Price 2004; 45
Knighton, Qian 2000; 9
Budenz, Fredette, Feuer 2008; 115
Brusini, Salvetat, Zeppieri 2006; 84
Medeiros, Zangwill, Bowd 2005; 139
Medeiros, Zangwill, Bowd 2004; 122
Cheng, Huang 2005; 243
Budenz, Chang, Huang 2005; 46
Schuman, Pedut-Kloizman, Hertzmark 1996; 103
Kok, van Dijk, van den Berg 2009; 50
Gabriele, Ishikawa, Wollstein 2007; 48
Wu, Vazeen, Varma 2007; 114
Vizzeri, Bowd, Medeiros 2008; 17
Proschan, Leifer 2006; 27
Chen, Cense, Pierce 2005; 123
van Velthoven, van der Linden, de Smet 2006; 90
Nassif, Cense, Hyle Park 2004; 29
Vizzeri, Bowd, Medeiros 2009; 18
Hanley, Negassa, Edwardes 2003; 157
Bagga, Greenfield 2004; 137
Sihota, Sony, Gupta 2006; 47
Jeoung, Park, Kim 2005; 112
Barkana, Bugansky-Eliash, Gerber 2009; 147
Budenz, Michael, Chang 2005; 112
Mills, Budenz, Lee 2006; 141
Stein, Wollstein, Ishikawa 2006; 113
References_xml – volume: 137
  start-page: 797
  year: 2004
  article-title: Quantitative assessment of structural damage in eyes with localized visual field abnormalities.
  publication-title: Am J Ophthalmol
– volume: 45
  start-page: 1716
  year: 2004
  article-title: Reproducibility of nerve fiber layer thickness, macular thickness, and optic nerve head measurements using StratusOCT.
  publication-title: Invest Ophthalmol Vis Sci
– volume: 114
  start-page: 1505
  year: 2007
  article-title: Factors associated with variability in retinal nerve fiber layer thickness measurements obtained by optical coherence tomography.
  publication-title: Ophthalmology
– volume: 29
  start-page: 480
  year: 2004
  article-title: In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography.
  publication-title: Opt Lett
– volume: 50
  start-page: 787
  year: 2009
  article-title: A model for the effect of disturbances in the optical media on the OCT image quality.
  publication-title: Invest Ophthalmol Vis Sci
– volume: 122
  start-page: 827
  year: 2004
  article-title: Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and Stratus OCT optical coherence tomograph for the detection of glaucoma.
  publication-title: Arch Ophthalmol
– volume: 46
  start-page: 2440
  year: 2005
  article-title: Reproducibility of retinal nerve fiber thickness measurements using the Stratus OCT in normal and glaucomatous eyes.
  publication-title: Invest Ophthalmol Vis Sci
– volume: 27
  start-page: 472
  year: 2006
  article-title: Comparison of two or more measurement techniques to a standard.
  publication-title: Contemp Clin Trials
– volume: 141
  start-page: 24
  year: 2006
  article-title: Categorizing the stage of glaucoma from pre-diagnosis to end-stage disease.
  publication-title: Am J Ophthalmol
– volume: 157
  start-page: 364
  year: 2003
  article-title: Statistical analysis of correlated data using Generalized Estimating Equations: an orientation.
  publication-title: Am J Epidemiol
– volume: 115
  start-page: 1347
  year: 2008
  article-title: Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography.
  publication-title: Ophthalmology
– volume: 8
  start-page: 135
  year: 1999
  article-title: Measuring agreement in method comparison studies.
  publication-title: Stat Meth Med Res
– volume: 47
  start-page: 2006
  year: 2006
  article-title: Diagnostic capability of optical coherence tomography in evaluating the degree of glaucomatous retinal nerve fiber damage.
  publication-title: Invest Ophthalmol Vis Sci
– volume: 254
  start-page: 1178
  year: 1991
  article-title: Optical coherence tomography.
  publication-title: Science
– volume: 112
  start-page: 2157
  year: 2005
  article-title: Diagnostic ability of optical coherence tomography with a normative database to detect localized retinal nerve fiber layer defects.
  publication-title: Ophthalmology
– volume: 28
  start-page: 2067
  year: 2003
  article-title: Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography.
  publication-title: Opt Lett
– volume: 17
  start-page: 341
  year: 2008
  article-title: Effect of improper scan alignment on retinal nerve fiber layer thickness measurements using Stratus optical coherence tomograph.
  publication-title: J Glaucoma
– volume: 139
  start-page: 44
  year: 2005
  article-title: Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography.
  publication-title: Am J Ophthalmol
– volume: 103
  start-page: 1889
  year: 1996
  article-title: Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography.
  publication-title: Ophthalmology
– volume: 9
  start-page: 56
  year: 2000
  article-title: An optical model of the human retinal nerve fiber layer: implications of directional reflectance for variability of clinical measurements.
  publication-title: J Glaucoma
– volume: 90
  start-page: 1259
  year: 2006
  article-title: Influence of cataract on optical coherence tomography image quality and retinal thickness.
  publication-title: Br J Ophthalmol
– volume: 26
  start-page: 57
  year: 2007
  article-title: Recent developments in optical coherence tomography for imaging the retina.
  publication-title: Progr Retin Eye Res
– volume: 84
  start-page: 650
  year: 2006
  article-title: Comparison between GDx VCC scanning laser polarimetry and Stratus OCT optical coherence tomography in the diagnosis of chronic glaucoma.
  publication-title: Acta Ophthalmol Scand
– volume: 7
  start-page: 457
  year: 2002
  article-title: In vivo human retinal imaging by Fourier domain optical coherence tomography.
  publication-title: J Biom Opt
– volume: 112
  start-page: 3
  year: 2005
  article-title: Sensitivity and specificity of the StratusOCT for perimetric glaucoma.
  publication-title: Ophthalmology
– volume: 48
  start-page: 3154
  year: 2007
  article-title: Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning.
  publication-title: Invest Ophthalmol Vis Sci
– volume: 18
  start-page: 81
  year: 2009
  article-title: Scan tracking coordinates for improved centering of Stratus OCT scan pattern.
  publication-title: J Glaucoma
– volume: 243
  start-page: 894
  year: 2005
  article-title: Discrimination between normal and glaucomatous eyes using Stratus optical coherence tomography in Taiwan Chinese subjects.
  publication-title: Graefes Arch Clin Exp Ophthalmol
– volume: 115
  start-page: 661
  year: 2008
  article-title: Reproducibility of peripapillary retinal nerve fiber thickness measurements with Stratus OCT in glaucomatous eyes.
  publication-title: Ophthalmology
– volume: 147
  start-page: 260
  year: 2009
  article-title: Inter-device variability of the Stratus optical coherence tomography.
  publication-title: Am J Ophthalmol
– volume: 123
  start-page: 1715
  year: 2005
  article-title: Spectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging.
  publication-title: Arch Ophthalmol
– volume: 113
  start-page: 985
  year: 2006
  article-title: Effect of corneal drying on optical coherence tomography.
  publication-title: Ophthalmology
SSID ssj0002617
Score 2.3508663
Snippet Background/aims:To evaluate spectral-domain (SD) optical coherence tomography (OCT) reproducibility and assess the agreement between SD-OCT and Time-Domain...
Background/aims: To evaluate spectral-domain (SD) optical coherence tomography (OCT) reproducibility and assess the agreement between SD-OCT and Time-Domain...
To evaluate spectral-domain (SD) optical coherence tomography (OCT) reproducibility and assess the agreement between SD-OCT and Time-Domain (TD) OCT retinal...
SourceID pubmedcentral
proquest
pubmed
pascalfrancis
crossref
istex
bmj
SourceType Open Access Repository
Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 775
SubjectTerms Aged
Agreements
Algorithms
Automation
Biological and medical sciences
Diagnostic Techniques, Ophthalmological
Female
Glaucoma
Glaucoma - pathology
Humans
Male
Medical sciences
Middle Aged
Miscellaneous
Multivariate analysis
Nerve Fibers - pathology
Nerve Fibers - ultrastructure
Ophthalmology
Optics
Prospective Studies
Reproducibility of Results
Retinal Neurons - cytology
Retinal Neurons - pathology
Software
Studies
Tomography
Tomography, Optical Coherence - instrumentation
Tomography, Optical Coherence - methods
Title Agreement between spectral-domain and time-domain OCT for measuring RNFL thickness
URI http://bjo.bmj.com/content/93/6/775.full
https://api.istex.fr/ark:/67375/NVC-X7QVLM3W-H/fulltext.pdf
https://www.ncbi.nlm.nih.gov/pubmed/19304586
https://www.proquest.com/docview/1778932049
https://www.proquest.com/docview/67286186
https://pubmed.ncbi.nlm.nih.gov/PMC3465953
Volume 93
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwhV3db9MwELdglRAviG8Co1gCIV7MktiJkyc0qlUVWgtU2-hb5NiO2EaTsXYSfz53tptRxMdbItuJdb7zne_O9yPkVaxEHvPCMlNazYThminQo8wWVhbalrxO8YLzdJZPjsWHRbYIDrdVSKvc7IluozadRh_5XiIlqNYUDNp3F98ZokZhdDVAaNwkA1e6DPhZLvoDl6s27s1fyRIwbUJpn4Tne_VZ5xMpscJeiZdT6uXZlm4aIJl_YK6kWgG5Go9z8SdD9Pd8yl8U1PguuRMsS7rvWeEeuWHb--TWNMTOH5D5PhytnTOQhuQs6q5ZwqeY6ZbqtKWqNRTB5jfvH0dHFIxaunSORFBydD4bH1JMkT_HLfIhOR4fHI0mLCAqsFoUyZrJJDGGG1lm2mhjYXnKpJGZLBWYeaLWiYLTXm2kUAJEtVFKNLrIUsNVKWIVK_6I7LRda58QGtexkLLRUoJEw7ZXaw6E5SbPjYXnJiIvgaLVha-ZUbmzBs8roLtHvvR0j8jbDcUrHYqSIzbGt78PeNMP-O-3X7sl7Pupy3NMY5NZNTsZVQv5-eRwyr9Uk4gMt9a4H4AYTikYkBHZ3Sx6FUR8VV0zZERe9M0gnBhxUa3trlbwt7RAQIKIPPYccj3n0oWooUVu8U7fAct-b7e0p19d-W8usAYkf_rvST0jt33gCx1Gu2RnfXlln4P9tK6HTkiGZPD-YPZp_hODmBjD
linkProvider ProQuest
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtR3ZbtNAcFQSCXhB3BhKuxKHeDG1vRuv_YBQCY1SmgSI0pI3s95di7bEKU0q4Kf4RmZ8lSCOp77ZWu96NTM7x84F8NhTIvR4ZF0TW-0Kw7WrUI66NrIy0jbmaUAJzsNR2N8Xb6ad6Rr8qHNhKKyy5okFozZzTXfkW76UKFoDVGhfnnxxqWsUeVfrFholWezZ71_RZFu82H2N-H0SBL2dSbfvVl0F3FRE_tKVvm8MNzLuaKONxS3GfiY7Mlao6ohU-wotntRIoQSSa6aUyHTUCQxXsfCUpziuewnagjJaW9B-tTN6N254P9U3LxVu6fqoTFXFhHwebqVH8zJ0k2r6xZQOk86OVqRhmxD7jaIz1QIRlJWdNf6k-v4ewfmLSOxdh2uVLsu2S-K7AWs2vwmXh5W3_haMt9GYL64fWRUOxorETlzKNfOZOsyZyg2j9vb1-9vuhKEazWbF1SWKVTYe9QaMgvKPiSnfhv0LgfYdaOXz3N4D5qWekDLTUiIPQUabao6A5SYMjcXnzIFHCNHkpKzSkRTWDQ8ThHvZa7OEuwPPa4gnuiqDTt04Pv99wrNmwn_XflqgsPlOnR5T4JzsJKODbjKV7w8GQ_4h6TuwsYLjZgJ1jQpQZXVgvUZ6UjGVRXJ-BBzYbIaRHZCPR-V2frbAvwURtUBw4G5JIed7jgunOI7IFdppPqBC46sj-eGnouA4F1R1kt__96Y24Up_Mhwkg93R3gO4Wrrd6LpqHVrL0zP7ELW3ZbpRHRkGHy_6lP4E6sNWMg
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtR3ZbtQwcFRaqeIFcZNSWksc4sVsEnvj5AGhastqS3cXqHrsW3BsR_TYpHS3An6Nr2PsHGURx1PfEjl2rLnHM54BeOZLHvksNlQnRlGumaIS9Sg1sRGxMgnLQnvBeTSOBgf83aQ7WYIfzV0Ym1bZyEQnqHWp7Bl5JxACVWuIBm0nr9MiPmz335x_obaDlI20Nu00KhLZNd-_ovs2e72zjbh-Hob9t_u9Aa07DNCMx8GciiDQmmmRdJVW2uB2kyAXXZFINHt4pgKJ3k-mBZccSTeXkucq7oaayYT70pcM170BK4KhVYW8JCats-cqnVemt6ABmlV1WaGARZ3spKySOG11v8RejMmmJwt6ccWi-JvN05QzRFVe9dj4kxH8ey7nL8qxfxtu1VYt2arI8A4smeIurI7quP092NtCt94dRJI6MYy4K564FNXlVB4XRBaa2Eb3zfv73j5Bg5pM3SEmKliyN-4PiU3PP7Xi-T4cXAusH8ByURbmERA_87kQuRICpQmK3EwxBCzTUaQNPucePEWIpudVvY7U-TksShHuVdfNCu4evGognqq6ILrty3H29wkv2wn_XfuFQ2H7nbw4tSl0opuOD3vpRHw8HI7YUTrwYGMBx-0E2z8qROPVg_UG6WktXmbpFTN4sNkOo2Cw0R5ZmPJyhn8LY9sMwYOHFYVc7Tlx4XEcEQu0035gS44vjhTHn13pccZt_Um29u9NbcIq8mY63BnvPoabVfzNnlutw_L84tI8QTNunm04fiHw6boZ9Cf611j5
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Agreement+between+spectral-domain+and+time-domain+OCT+for+measuring+RNFL+thickness&rft.jtitle=British+journal+of+ophthalmology&rft.au=Vizzeri%2C+G&rft.au=Weinreb%2C+R+N&rft.au=Gonzalez-Garcia%2C+A+O&rft.au=Bowd%2C+C&rft.date=2009-06-01&rft.pub=BMJ+Publishing+Group+LTD&rft.issn=0007-1161&rft.eissn=1468-2079&rft.volume=93&rft.issue=6&rft.spage=775&rft_id=info:doi/10.1136%2Fbjo.2008.150698&rft.externalDBID=HAS_PDF_LINK&rft.externalDocID=4012486581
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0007-1161&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0007-1161&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0007-1161&client=summon