Agreement between spectral-domain and time-domain OCT for measuring RNFL thickness

Background/aims:To evaluate spectral-domain (SD) optical coherence tomography (OCT) reproducibility and assess the agreement between SD-OCT and Time-Domain (TD) OCT retinal nerve fibre layer (RNFL) measurements.Methods:Three Cirrus-SD-OCT scans and one Stratus-TD-OCT scan were obtained from Diagnost...

Full description

Saved in:
Bibliographic Details
Published inBritish journal of ophthalmology Vol. 93; no. 6; pp. 775 - 781
Main Authors Vizzeri, G, Weinreb, R N, Gonzalez-Garcia, A O, Bowd, C, Medeiros, F A, Sample, P A, Zangwill, L M
Format Journal Article
LanguageEnglish
Published BMA House, Tavistock Square, London, WC1H 9JR BMJ Publishing Group Ltd 01.06.2009
BMJ Publishing Group
BMJ Publishing Group LTD
Subjects
Online AccessGet full text
ISSN0007-1161
1468-2079
1468-2079
DOI10.1136/bjo.2008.150698

Cover

Loading…
More Information
Summary:Background/aims:To evaluate spectral-domain (SD) optical coherence tomography (OCT) reproducibility and assess the agreement between SD-OCT and Time-Domain (TD) OCT retinal nerve fibre layer (RNFL) measurements.Methods:Three Cirrus-SD-OCT scans and one Stratus-TD-OCT scan were obtained from Diagnostic Innovations in Glaucoma Study (DIGS) healthy participants and glaucoma patients on the same day. Repeatability was evaluated using Sw (within-subject standard deviation), CV (coefficient of variation) and ICC (intraclass correlation coefficient). Agreement was assessed using correlation and Bland–Altman plots.Results:16 healthy participants (32 eyes) and 39 patients (78 eyes) were included. SD-OCT reproducibility was excellent in both groups. The CV and ICC for Average RNFL thickness were 1.5% and 0.96, respectively, in healthy eyes and 1.6% and 0.98, respectively, in patient eyes. Correlations between RNFL parameters were strong, particularly for average RNFL thickness (R2 = 0.92 in patient eyes). Bland–Altman plots showed good agreement between instruments, with better agreement for average RNFL thickness than for sectoral RNFL parameters (for example, at 90 µm average RNFL thickness, 95% limits of agreement were −13.1 to 0.9 for healthy eyes and −16.2 to −0.3 µm for patient eyes).Conclusions:SD-OCT measurements were highly repeatable in healthy and patient eyes. Although the agreement between instruments was good, TD-OCT provided thicker RNFL measurements than SD-OCT. Measurements with these instruments should not be considered interchangeable.
Bibliography:ark:/67375/NVC-X7QVLM3W-H
local:bjophthalmol;93/6/775
href:bjophthalmol-93-775.pdf
ArticleID:bj150698
PMID:19304586
istex:F9B6259F0E062FBA1BADDCFE4D6046AC73C0544E
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
ISSN:0007-1161
1468-2079
1468-2079
DOI:10.1136/bjo.2008.150698