An FBG-based Stiffness Estimation Sensor for In-vivo Diagnostics

In-vivo tissue stiffness identification can be useful in pulmonary fibrosis diagnostics and minimally invasive tumor identification, among many other applications. In this work, we propose a palpation-based method for tissue stiffness estimation that uses a sensorized beam buckled onto the surface o...

Full description

Saved in:
Bibliographic Details
Main Authors Moradkhani, Behnam, Kheradmand, Pejman, Jella, Harshith, Yamamoto, Kent K, Tofangchi, Alireza, Codd, Patrick J, Chitalia, Yash
Format Journal Article
LanguageEnglish
Published 30.05.2024
Subjects
Online AccessGet full text

Cover

Loading…
Abstract In-vivo tissue stiffness identification can be useful in pulmonary fibrosis diagnostics and minimally invasive tumor identification, among many other applications. In this work, we propose a palpation-based method for tissue stiffness estimation that uses a sensorized beam buckled onto the surface of a tissue. Fiber Bragg Gratings (FBGs) are used in our sensor as a shape-estimation modality to get real-time beam shape, even while the device is not visually monitored. A mechanical model is developed to predict the behavior of a buckling beam and is validated using finite element analysis and bench-top testing with phantom tissue samples (made of PDMS and PA-Gel). Bench-top estimations were conducted and the results were compared with the actual stiffness values. Mean RMSE and standard deviation (from the actual stiffnesses) values of 413.86 KPa and 313.82 KPa were obtained. Estimations for softer samples were relatively closer to the actual values. Ultimately, we used the stiffness sensor within a mock concentric tube robot as a demonstration of \textit{in-vivo} sensor feasibility. Bench-top trials with and without the robot demonstrate the effectiveness of this unique sensing modality in \textit{in-vivo} applications.
AbstractList In-vivo tissue stiffness identification can be useful in pulmonary fibrosis diagnostics and minimally invasive tumor identification, among many other applications. In this work, we propose a palpation-based method for tissue stiffness estimation that uses a sensorized beam buckled onto the surface of a tissue. Fiber Bragg Gratings (FBGs) are used in our sensor as a shape-estimation modality to get real-time beam shape, even while the device is not visually monitored. A mechanical model is developed to predict the behavior of a buckling beam and is validated using finite element analysis and bench-top testing with phantom tissue samples (made of PDMS and PA-Gel). Bench-top estimations were conducted and the results were compared with the actual stiffness values. Mean RMSE and standard deviation (from the actual stiffnesses) values of 413.86 KPa and 313.82 KPa were obtained. Estimations for softer samples were relatively closer to the actual values. Ultimately, we used the stiffness sensor within a mock concentric tube robot as a demonstration of \textit{in-vivo} sensor feasibility. Bench-top trials with and without the robot demonstrate the effectiveness of this unique sensing modality in \textit{in-vivo} applications.
Author Moradkhani, Behnam
Jella, Harshith
Codd, Patrick J
Tofangchi, Alireza
Chitalia, Yash
Kheradmand, Pejman
Yamamoto, Kent K
Author_xml – sequence: 1
  givenname: Behnam
  surname: Moradkhani
  fullname: Moradkhani, Behnam
– sequence: 2
  givenname: Pejman
  surname: Kheradmand
  fullname: Kheradmand, Pejman
– sequence: 3
  givenname: Harshith
  surname: Jella
  fullname: Jella, Harshith
– sequence: 4
  givenname: Kent K
  surname: Yamamoto
  fullname: Yamamoto, Kent K
– sequence: 5
  givenname: Alireza
  surname: Tofangchi
  fullname: Tofangchi, Alireza
– sequence: 6
  givenname: Patrick J
  surname: Codd
  fullname: Codd, Patrick J
– sequence: 7
  givenname: Yash
  surname: Chitalia
  fullname: Chitalia, Yash
BackLink https://doi.org/10.48550/arXiv.2405.20509$$DView paper in arXiv
BookMark eNotj71OwzAUhT3AUAoP0Am_gIPjn9jeKKUtlSoxtHt0nVwjS2CjOIrg7QmF4egsR5_Od0OuUk5IyKrmlbJa8wcYvuJUCcV1JbjmbkEe14nunvbMQ8GensYYQsJS6LaM8QPGmBM9YSp5oGHOIbEpTpk-R3hLeZ505ZZcB3gvePffS3Lebc-bF3Z83R826yODxjimJYrGK64QsFfeCKN6UCKg8pYraT0EZbgNDvvaSgjWYOccdNyIUDfSyCW5_8NeFNrPYX43fLe_Ku1FRf4AKttE-g
ContentType Journal Article
Copyright http://arxiv.org/licenses/nonexclusive-distrib/1.0
Copyright_xml – notice: http://arxiv.org/licenses/nonexclusive-distrib/1.0
DBID AKY
GOX
DOI 10.48550/arxiv.2405.20509
DatabaseName arXiv Computer Science
arXiv.org
DatabaseTitleList
Database_xml – sequence: 1
  dbid: GOX
  name: arXiv.org
  url: http://arxiv.org/find
  sourceTypes: Open Access Repository
DeliveryMethod fulltext_linktorsrc
ExternalDocumentID 2405_20509
GroupedDBID AKY
GOX
ID FETCH-LOGICAL-a679-53e26b404eaed4b7274da42fe4b80438baf4708f9ed183af87ec99ac072f16373
IEDL.DBID GOX
IngestDate Tue Jun 04 19:27:36 EDT 2024
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-a679-53e26b404eaed4b7274da42fe4b80438baf4708f9ed183af87ec99ac072f16373
OpenAccessLink https://arxiv.org/abs/2405.20509
ParticipantIDs arxiv_primary_2405_20509
PublicationCentury 2000
PublicationDate 2024-05-30
PublicationDateYYYYMMDD 2024-05-30
PublicationDate_xml – month: 05
  year: 2024
  text: 2024-05-30
  day: 30
PublicationDecade 2020
PublicationYear 2024
Score 1.9272487
SecondaryResourceType preprint
Snippet In-vivo tissue stiffness identification can be useful in pulmonary fibrosis diagnostics and minimally invasive tumor identification, among many other...
SourceID arxiv
SourceType Open Access Repository
SubjectTerms Computer Science - Robotics
Title An FBG-based Stiffness Estimation Sensor for In-vivo Diagnostics
URI https://arxiv.org/abs/2405.20509
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwdZ1NTwMhEIZJ7cmL0aipn-HglUhZ2GVvVu22mqiH1mRvG1iGpJfW1Lbx5zvAGr145OPCEHifyTADITdQKucsL5nWecakMsBMzg0bYnPYWt62MT365TWfvsvnWtU9Qn9yYcz6a7FL9YHt5y3KjUIfToUMvT0hwpOtyVudgpOxFFc3_3ceMmbs-iMS1SE56OiOjtJ2HJEeLI_J3WhJq_sJC4Lh6Gyz8D7cL3SMpyslDtIZOpOrNUWApE9LtlvsVvQxvYELVZRPyLwazx-mrPu4ANdZlExlIHIruQQDTlokBOmMFB6k1SHwZo2XBde-BIcHynhdQFuWpuWF8IhHRXZK-uj7w4DQDAGtNcgE1iB7GaQtwFtBqCx3oMHpMzKIy20-Um2KJliiiZY4_3_oguwL1OYYBOeXpL9Zb-EKtXVjr6OBvwHCW3hz
link.rule.ids 228,230,786,891
linkProvider Cornell University
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=An+FBG-based+Stiffness+Estimation+Sensor+for+In-vivo+Diagnostics&rft.au=Moradkhani%2C+Behnam&rft.au=Kheradmand%2C+Pejman&rft.au=Jella%2C+Harshith&rft.au=Yamamoto%2C+Kent+K&rft.date=2024-05-30&rft_id=info:doi/10.48550%2Farxiv.2405.20509&rft.externalDocID=2405_20509