Carbon Fiber Ionization Mass Spectrometry for the Analysis of Analytes in Vapor, Liquid, and Solid Phases
Various ionization methods in mass spectrometry (MS) are available for the analysis of analytes with different properties. Nonetheless, the use of a single ionization method to analyze mixtures containing analytes with different polarities and volatilities in different phases at atmospheric pressure...
Saved in:
Published in | Analytical chemistry (Washington) Vol. 89; no. 24; pp. 13458 - 13465 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
United States
American Chemical Society
19.12.2017
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Various ionization methods in mass spectrometry (MS) are available for the analysis of analytes with different properties. Nonetheless, the use of a single ionization method to analyze mixtures containing analytes with different polarities and volatilities in different phases at atmospheric pressure remains a challenge. Exploring an ionization method that can ionize small organics and large biomolecules with different properties for MS analysis is advantageous. Carbon fiber ionization mass spectrometry (CFI-MS), which uses a carbon fiber bundle as the ion source, is useful for the analysis of small organics with low polarities. Voltage needs to be applied on the carbon fiber bundle to initiate corona discharge for ionization of analytes. In this study, we explore the suitability of using CFI-MS in the analysis of analytes in vapor, liquid, and solid phases using a single carbon fiber (length : ∼1 cm; diameter: ∼10 μm) as the ion source. Furthermore direct electric contact on the carbon fiber is not required. We demonstrate that CFI-MS is useful for analyzing not only small and low-polarity organics but also polar biomolecules, such as peptides and proteins. The limits of detection for analytes with high polarities such as dodecyl trimethylammonium bromide and bradykinin are estimated to be ∼16 and ∼53 pM, respectively. Ionization mechanisms, including corona discharge and electrospray, are involved in the ionization of analytes with the polarity from low to high. Furthermore, sesame oil containing aromatic volatiles and compounds with different polarities is used as a model sample to demonstrate the capability of the developed ionization method to provide comprehensive chemical information from a complex sample. In addition, the feasibility of using the developed method for quantitative analysis of nonpolar as well as medium and high polarity analytes is also demonstrated. The sensitivity of the developed method toward analytes with high polarity is higher than those with low polarity. The method precision was estimated to be ∼7.8%. |
---|---|
AbstractList | Various ionization methods in mass spectrometry (MS) are available for the analysis of analytes with different properties. Nonetheless, the use of a single ionization method to analyze mixtures containing analytes with different polarities and volatilities in different phases at atmospheric pressure remains a challenge. Exploring an ionization method that can ionize small organics and large biomolecules with different properties for MS analysis is advantageous. Carbon fiber ionization mass spectrometry (CFI-MS), which uses a carbon fiber bundle as the ion source, is useful for the analysis of small organics with low polarities. Voltage needs to be applied on the carbon fiber bundle to initiate corona discharge for ionization of analytes. In this study, we explore the suitability of using CFI-MS in the analysis of analytes in vapor, liquid, and solid phases using a single carbon fiber (length : ∼1 cm; diameter: ∼10 μm) as the ion source. Furthermore direct electric contact on the carbon fiber is not required. We demonstrate that CFI-MS is useful for analyzing not only small and low-polarity organics but also polar biomolecules, such as peptides and proteins. The limits of detection for analytes with high polarities such as dodecyl trimethylammonium bromide and bradykinin are estimated to be ∼16 and ∼53 pM, respectively. Ionization mechanisms, including corona discharge and electrospray, are involved in the ionization of analytes with the polarity from low to high. Furthermore, sesame oil containing aromatic volatiles and compounds with different polarities is used as a model sample to demonstrate the capability of the developed ionization method to provide comprehensive chemical information from a complex sample. In addition, the feasibility of using the developed method for quantitative analysis of nonpolar as well as medium and high polarity analytes is also demonstrated. The sensitivity of the developed method toward analytes with high polarity is higher than those with low polarity. The method precision was estimated to be ∼7.8%.Various ionization methods in mass spectrometry (MS) are available for the analysis of analytes with different properties. Nonetheless, the use of a single ionization method to analyze mixtures containing analytes with different polarities and volatilities in different phases at atmospheric pressure remains a challenge. Exploring an ionization method that can ionize small organics and large biomolecules with different properties for MS analysis is advantageous. Carbon fiber ionization mass spectrometry (CFI-MS), which uses a carbon fiber bundle as the ion source, is useful for the analysis of small organics with low polarities. Voltage needs to be applied on the carbon fiber bundle to initiate corona discharge for ionization of analytes. In this study, we explore the suitability of using CFI-MS in the analysis of analytes in vapor, liquid, and solid phases using a single carbon fiber (length : ∼1 cm; diameter: ∼10 μm) as the ion source. Furthermore direct electric contact on the carbon fiber is not required. We demonstrate that CFI-MS is useful for analyzing not only small and low-polarity organics but also polar biomolecules, such as peptides and proteins. The limits of detection for analytes with high polarities such as dodecyl trimethylammonium bromide and bradykinin are estimated to be ∼16 and ∼53 pM, respectively. Ionization mechanisms, including corona discharge and electrospray, are involved in the ionization of analytes with the polarity from low to high. Furthermore, sesame oil containing aromatic volatiles and compounds with different polarities is used as a model sample to demonstrate the capability of the developed ionization method to provide comprehensive chemical information from a complex sample. In addition, the feasibility of using the developed method for quantitative analysis of nonpolar as well as medium and high polarity analytes is also demonstrated. The sensitivity of the developed method toward analytes with high polarity is higher than those with low polarity. The method precision was estimated to be ∼7.8%. Various ionization methods in mass spectrometry (MS) are available for the analysis of analytes with different properties. Nonetheless, the use of a single ionization method to analyze mixtures containing analytes with different polarities and volatilities in different phases at atmospheric pressure remains a challenge. Exploring an ionization method that can ionize small organics and large biomolecules with different properties for MS analysis is advantageous. Carbon fiber ionization mass spectrometry (CFI-MS), which uses a carbon fiber bundle as the ion source, is useful for the analysis of small organics with low polarities. Voltage needs to be applied on the carbon fiber bundle to initiate corona discharge for ionization of analytes. In this study, we explore the suitability of using CFI-MS in the analysis of analytes in vapor, liquid, and solid phases using a single carbon fiber (length : ∼1 cm; diameter: ∼10 μm) as the ion source. Furthermore direct electric contact on the carbon fiber is not required. We demonstrate that CFI-MS is useful for analyzing not only small and low-polarity organics but also polar biomolecules, such as peptides and proteins. The limits of detection for analytes with high polarities such as dodecyl trimethylammonium bromide and bradykinin are estimated to be ∼16 and ∼53 pM, respectively. Ionization mechanisms, including corona discharge and electrospray, are involved in the ionization of analytes with the polarity from low to high. Furthermore, sesame oil containing aromatic volatiles and compounds with different polarities is used as a model sample to demonstrate the capability of the developed ionization method to provide comprehensive chemical information from a complex sample. In addition, the feasibility of using the developed method for quantitative analysis of nonpolar as well as medium and high polarity analytes is also demonstrated. The sensitivity of the developed method toward analytes with high polarity is higher than those with low polarity. The method precision was estimated to be ∼7.8%. Various ionization methods in mass spectrometry (MS) are available for the analysis of analytes with different properties. Nonetheless, the use of a single ionization method to analyze mixtures containing analytes with different polarities and volatilities in different phases at atmospheric pressure remains a challenge. Exploring an ionization method that can ionize small organics and large biomolecules with different properties for MS analysis is advantageous. Carbon fiber ionization mass spectrometry (CFI-MS), which uses a carbon fiber bundle as the ion source, is useful for the analysis of small organics with low polarities. Voltage needs to be applied on the carbon fiber bundle to initiate corona discharge for ionization of analytes. In this study, we explore the suitability of using CFI-MS in the analysis of analytes in vapor, liquid, and solid phases using a single carbon fiber (length : ~1 cm; diameter: ~10 7mgr;m) as the ion source. Furthermore direct electric contact on the carbon fiber is not required. We demonstrate that CFI-MS is useful for analyzing not only small and low-polarity organics but also polar biomolecules, such as peptides and proteins. The limits of detection for analytes with high polarities such as dodecyl trimethylammonium bromide and bradykinin are estimated to be ~16 and ~53 pM, respectively. Ionization mechanisms, including corona discharge and electrospray, are involved in the ionization of analytes with the polarity from low to high. Furthermore, sesame oil containing aromatic volatiles and compounds with different polarities is used as a model sample to demonstrate the capability of the developed ionization method to provide comprehensive chemical information from a complex sample. In addition, the feasibility of using the developed method for quantitative analysis of nonpolar as well as medium and high polarity analytes is also demonstrated. The sensitivity of the developed method toward analytes with high polarity is higher than those with low polarity. The method precision was estimated to be ~7.8%. |
Author | Chen, Yu-Chie Chen, Te-Yu Wu, Min-Li Chen, Yen-Chun |
AuthorAffiliation | Department of Applied Chemistry National Chiao Tung University |
AuthorAffiliation_xml | – name: National Chiao Tung University – name: Department of Applied Chemistry |
Author_xml | – sequence: 1 givenname: Min-Li surname: Wu fullname: Wu, Min-Li – sequence: 2 givenname: Te-Yu surname: Chen fullname: Chen, Te-Yu – sequence: 3 givenname: Yen-Chun surname: Chen fullname: Chen, Yen-Chun – sequence: 4 givenname: Yu-Chie orcidid: 0000-0003-2253-4049 surname: Chen fullname: Chen, Yu-Chie email: yuchie@mail.nctu.edu.tw |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/29155550$$D View this record in MEDLINE/PubMed |
BookMark | eNqFkU1v1DAQhi1URLeFf4CQJS49NMvYiT_CrVpRqLQIpAJXy3EmWldJvLWTw_Lr8bK7QuqB-jKW53nHM_NekLMxjEjIWwZLBpx9sC4t7Wh7t8FhqRooVSlfkAUTHAqpNT8jCwAoC64AzslFSg8AjAGTr8g5r5nIBxbEr2xswkhvfYOR3oXR_7aTzw9fbUr0fotuimHAKe5oFyKdNkhv8qe75BMN3eE-YaJ-pL_sNsRruvaPs2-vqR1beh9639LvG5swvSYvO9snfHOMl-Tn7acfqy_F-tvnu9XNurCC8akoXQOONaVzTlVKMSGV40prJUBL51CKPILGmqOoLZRSdLrtOrDokGmhq_KSXB3qbmN4nDFNZvDJYd_bEcOcDAepuBZSq2dRVktZ11VuIaPvn6APYY55-j2lOVMV5zpT747U3AzYmm30g407c9p3Bj4eABdDShE74_z0d-FTtL43DMzeXJPNNSdzzdHcLK6eiE_1n5HBQbbP_uv6f5I_gji6_A |
CitedBy_id | crossref_primary_10_1007_s00216_022_04080_w crossref_primary_10_1007_s00216_024_05282_0 crossref_primary_10_3390_molecules29010137 crossref_primary_10_3390_molecules26226760 crossref_primary_10_1021_acsomega_1c06869 crossref_primary_10_1016_j_aca_2018_10_037 crossref_primary_10_1002_jms_4289 crossref_primary_10_1016_j_aca_2018_10_016 crossref_primary_10_1016_j_chroma_2023_463958 crossref_primary_10_1007_s00216_023_04917_y crossref_primary_10_1016_j_trac_2021_116202 crossref_primary_10_1016_j_aca_2025_343817 crossref_primary_10_1002_jms_4307 crossref_primary_10_5702_massspectrometry_A0146 crossref_primary_10_1021_acs_analchem_1c04926 crossref_primary_10_1007_s00216_020_02769_4 crossref_primary_10_1177_14690667241236073 crossref_primary_10_1021_acs_analchem_4c03157 crossref_primary_10_3390_separations9080199 crossref_primary_10_1016_j_foodchem_2023_136610 crossref_primary_10_1016_j_aca_2024_343560 crossref_primary_10_1021_acs_analchem_4c02086 crossref_primary_10_1007_s00216_018_1539_z crossref_primary_10_1007_s00216_023_05022_w crossref_primary_10_1021_acs_analchem_3c02589 crossref_primary_10_1016_j_snb_2022_132324 crossref_primary_10_1186_s13065_019_0641_4 crossref_primary_10_2139_ssrn_4123085 crossref_primary_10_1177_14690667221133388 |
Cites_doi | 10.1021/ac050162j 10.1002/jms.2983 10.1039/B818541G 10.1021/ac60364a031 10.1070/RCR4508 10.1016/j.aca.2016.07.011 10.1021/ac60342a009 10.1021/j150664a002 10.1093/chromsci/12.11.725 10.1039/C5RA17878A 10.1126/science.2675315 10.1663/0013-0001(2004)058[0330:HALOSI]2.0.CO;2 10.5702/massspectrometry.S0057 10.2116/analsci.21.1457 10.1002/jms.3546 10.1021/ac0001636 10.1021/ac200479s 10.1002/jms.621 10.1002/rcm.2243 10.1021/ac030419i 10.1074/mcp.M900527-MCP200 10.1021/jf960115f 10.1021/ac025659x 10.1021/acs.analchem.6b02074 10.1371/journal.pone.0066292 10.1021/ac60328a035 10.1039/b602614a 10.1021/ac702216q 10.1002/anie.201311053 10.1021/acs.analchem.6b02166 10.1021/acs.analchem.6b02152 10.1002/9781118887332 10.1039/c3cs35389c 10.1126/science.1119426 10.1002/rcm.862 |
ContentType | Journal Article |
Copyright | Copyright © 2017 American Chemical Society Copyright American Chemical Society Dec 19, 2017 |
Copyright_xml | – notice: Copyright © 2017 American Chemical Society – notice: Copyright American Chemical Society Dec 19, 2017 |
DBID | AAYXX CITATION NPM 7QF 7QO 7QQ 7SC 7SE 7SP 7SR 7TA 7TB 7TM 7U5 7U7 7U9 8BQ 8FD C1K F28 FR3 H8D H8G H94 JG9 JQ2 KR7 L7M L~C L~D P64 7X8 7S9 L.6 |
DOI | 10.1021/acs.analchem.7b03736 |
DatabaseName | CrossRef PubMed Aluminium Industry Abstracts Biotechnology Research Abstracts Ceramic Abstracts Computer and Information Systems Abstracts Corrosion Abstracts Electronics & Communications Abstracts Engineered Materials Abstracts Materials Business File Mechanical & Transportation Engineering Abstracts Nucleic Acids Abstracts Solid State and Superconductivity Abstracts Toxicology Abstracts Virology and AIDS Abstracts METADEX Technology Research Database Environmental Sciences and Pollution Management ANTE: Abstracts in New Technology & Engineering Engineering Research Database Aerospace Database Copper Technical Reference Library AIDS and Cancer Research Abstracts Materials Research Database ProQuest Computer Science Collection Civil Engineering Abstracts Advanced Technologies Database with Aerospace Computer and Information Systems Abstracts Academic Computer and Information Systems Abstracts Professional Biotechnology and BioEngineering Abstracts MEDLINE - Academic AGRICOLA AGRICOLA - Academic |
DatabaseTitle | CrossRef PubMed Materials Research Database Technology Research Database Computer and Information Systems Abstracts – Academic Mechanical & Transportation Engineering Abstracts Nucleic Acids Abstracts ProQuest Computer Science Collection Computer and Information Systems Abstracts Materials Business File Environmental Sciences and Pollution Management Aerospace Database Copper Technical Reference Library Engineered Materials Abstracts Biotechnology Research Abstracts AIDS and Cancer Research Abstracts Advanced Technologies Database with Aerospace ANTE: Abstracts in New Technology & Engineering Civil Engineering Abstracts Aluminium Industry Abstracts Virology and AIDS Abstracts Toxicology Abstracts Electronics & Communications Abstracts Ceramic Abstracts METADEX Biotechnology and BioEngineering Abstracts Computer and Information Systems Abstracts Professional Solid State and Superconductivity Abstracts Engineering Research Database Corrosion Abstracts MEDLINE - Academic AGRICOLA AGRICOLA - Academic |
DatabaseTitleList | MEDLINE - Academic Materials Research Database PubMed AGRICOLA |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering Chemistry |
EISSN | 1520-6882 |
EndPage | 13465 |
ExternalDocumentID | 29155550 10_1021_acs_analchem_7b03736 c80760923 |
Genre | Research Support, Non-U.S. Gov't Journal Article |
GroupedDBID | - .K2 02 1AW 23M 53G 53T 55A 5GY 5RE 5VS 7~N 85S AABXI ABFLS ABMVS ABOCM ABPPZ ABPTK ABUCX ABUFD ACGFS ACGOD ACIWK ACJ ACNCT ACPRK ACS AEESW AENEX AFEFF AFRAH ALMA_UNASSIGNED_HOLDINGS AQSVZ BAANH BKOMP CS3 D0L DZ EBS ED ED~ EJD F20 F5P GNL IH9 IHE JG JG~ K2 P2P PQEST PQQKQ ROL RXW TAE TN5 UHB UI2 UKR VF5 VG9 VQA W1F WH7 X X6Y XFK YZZ --- -DZ -~X .DC 4.4 6J9 AAHBH AAYXX ABBLG ABHFT ABHMW ABJNI ABLBI ABQRX ACBEA ACGFO ACKOT ADHLV AGXLV AHGAQ CITATION CUPRZ GGK KZ1 LMP XSW ZCA ~02 NPM YIN 7QF 7QO 7QQ 7SC 7SE 7SP 7SR 7TA 7TB 7TM 7U5 7U7 7U9 8BQ 8FD C1K F28 FR3 H8D H8G H94 JG9 JQ2 KR7 L7M L~C L~D P64 7X8 7S9 L.6 |
ID | FETCH-LOGICAL-a512t-3cb0c1b3ccc74771567c278875086cce650168e92e59a0365f8dff0aece185843 |
IEDL.DBID | ACS |
ISSN | 0003-2700 1520-6882 |
IngestDate | Fri Jul 11 08:01:31 EDT 2025 Fri Jul 11 06:54:33 EDT 2025 Mon Jun 30 10:16:38 EDT 2025 Wed Feb 19 02:32:31 EST 2025 Tue Jul 01 04:15:04 EDT 2025 Thu Apr 24 23:01:25 EDT 2025 Thu Aug 27 13:42:28 EDT 2020 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 24 |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-a512t-3cb0c1b3ccc74771567c278875086cce650168e92e59a0365f8dff0aece185843 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ORCID | 0000-0003-2253-4049 |
PMID | 29155550 |
PQID | 1982174228 |
PQPubID | 45400 |
PageCount | 8 |
ParticipantIDs | proquest_miscellaneous_2067285687 proquest_miscellaneous_1966994567 proquest_journals_1982174228 pubmed_primary_29155550 crossref_citationtrail_10_1021_acs_analchem_7b03736 crossref_primary_10_1021_acs_analchem_7b03736 acs_journals_10_1021_acs_analchem_7b03736 |
ProviderPackageCode | JG~ 55A AABXI GNL VF5 7~N ACJ VG9 W1F ACS AEESW AFEFF .K2 ABMVS ABUCX IH9 BAANH AQSVZ ED~ UI2 CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2017-12-19 |
PublicationDateYYYYMMDD | 2017-12-19 |
PublicationDate_xml | – month: 12 year: 2017 text: 2017-12-19 day: 19 |
PublicationDecade | 2010 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States – name: Washington |
PublicationTitle | Analytical chemistry (Washington) |
PublicationTitleAlternate | Anal. Chem |
PublicationYear | 2017 |
Publisher | American Chemical Society |
Publisher_xml | – name: American Chemical Society |
References | ref9/cit9 ref6/cit6 ref36/cit36 ref3/cit3 ref27/cit27 ref18/cit18 ref11/cit11 ref25/cit25 ref29/cit29 ref32/cit32 ref23/cit23 ref14/cit14 ref8/cit8 ref5/cit5 ref31/cit31 ref2/cit2 ref37/cit37 ref28/cit28 ref20/cit20 ref17/cit17 ref26/cit26 Bedigian D. (ref34/cit34) 2004; 58 ref35/cit35 Urban P. L. (ref10/cit10) 2016 ref19/cit19 ref21/cit21 ref12/cit12 ref15/cit15 ref22/cit22 ref13/cit13 ref33/cit33 ref4/cit4 ref30/cit30 ref1/cit1 ref24/cit24 ref7/cit7 |
References_xml | – ident: ref11/cit11 doi: 10.1021/ac050162j – ident: ref27/cit27 doi: 10.1002/jms.2983 – ident: ref19/cit19 doi: 10.1039/B818541G – ident: ref7/cit7 doi: 10.1021/ac60364a031 – ident: ref9/cit9 doi: 10.1070/RCR4508 – ident: ref31/cit31 doi: 10.1016/j.aca.2016.07.011 – ident: ref6/cit6 doi: 10.1021/ac60342a009 – ident: ref2/cit2 doi: 10.1021/j150664a002 – ident: ref5/cit5 doi: 10.1093/chromsci/12.11.725 – ident: ref30/cit30 doi: 10.1039/C5RA17878A – ident: ref3/cit3 doi: 10.1126/science.2675315 – volume: 58 start-page: 329 issue: 3 year: 2004 ident: ref34/cit34 publication-title: Econ. Bot. doi: 10.1663/0013-0001(2004)058[0330:HALOSI]2.0.CO;2 – ident: ref17/cit17 doi: 10.5702/massspectrometry.S0057 – ident: ref37/cit37 doi: 10.2116/analsci.21.1457 – ident: ref29/cit29 doi: 10.1002/jms.3546 – ident: ref33/cit33 doi: 10.1093/chromsci/12.11.725 – ident: ref14/cit14 doi: 10.1021/ac0001636 – ident: ref26/cit26 doi: 10.1021/ac200479s – ident: ref21/cit21 doi: 10.1002/jms.621 – ident: ref13/cit13 doi: 10.1002/rcm.2243 – ident: ref23/cit23 doi: 10.1021/ac030419i – ident: ref22/cit22 doi: 10.1074/mcp.M900527-MCP200 – ident: ref35/cit35 doi: 10.1021/jf960115f – ident: ref15/cit15 doi: 10.1021/ac025659x – ident: ref20/cit20 doi: 10.1021/acs.analchem.6b02074 – ident: ref28/cit28 doi: 10.1371/journal.pone.0066292 – ident: ref4/cit4 doi: 10.1021/ac60328a035 – ident: ref18/cit18 doi: 10.1039/b602614a – ident: ref12/cit12 doi: 10.1021/ac702216q – ident: ref25/cit25 doi: 10.1002/anie.201311053 – ident: ref24/cit24 doi: 10.1021/acs.analchem.6b02166 – ident: ref32/cit32 doi: 10.1021/acs.analchem.6b02152 – volume-title: Time-Resolved Mass Spectrometry: From Concept to Applications year: 2016 ident: ref10/cit10 doi: 10.1002/9781118887332 – ident: ref1/cit1 doi: 10.1039/c3cs35389c – ident: ref8/cit8 doi: 10.1126/science.1119426 – ident: ref36/cit36 doi: 10.1002/rcm.862 |
SSID | ssj0011016 |
Score | 2.3931315 |
Snippet | Various ionization methods in mass spectrometry (MS) are available for the analysis of analytes with different properties. Nonetheless, the use of a single... |
SourceID | proquest pubmed crossref acs |
SourceType | Aggregation Database Index Database Enrichment Source Publisher |
StartPage | 13458 |
SubjectTerms | Analytical chemistry Aromatic compounds atmospheric pressure Biomolecules Bradykinin bromides Carbon carbon fibers Chemistry detection limit Electric contacts electric power Feasibility studies Fluids Gases Ionization Ions liquids Mass spectrometry Mass spectroscopy Peptides Polarity Proteins Quantitative analysis Sensitivity analysis Sesame oil Solid phases Solids Spectroscopy Vapors Volatile compounds Volatiles |
Title | Carbon Fiber Ionization Mass Spectrometry for the Analysis of Analytes in Vapor, Liquid, and Solid Phases |
URI | http://dx.doi.org/10.1021/acs.analchem.7b03736 https://www.ncbi.nlm.nih.gov/pubmed/29155550 https://www.proquest.com/docview/1982174228 https://www.proquest.com/docview/1966994567 https://www.proquest.com/docview/2067285687 |
Volume | 89 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV3JTsMwEB2xHIAD-1I2GYkLEi6J02Y5ooqqIDaJRdwix3FEREmAphe-npkmLgVUAbcosSN7PM68yXjeAOwTiZywlM0dtBa8IUTApSUUpzxd4SBATTT90L-4dDt3jbOH5sOno_g9gi_sI6l6dYlCxTk8173IcjzHnYRp4eI-JijUuhlGDcgTNRXyKKBqUuXGvIUMkup9NUhjUObA2rQX4Mrk7JSHTJ7q_SKqq_efFI5_nMgizFfAkx2XmrIEEzpbhpmWqfe2DHMj1IQrkLbkW5RnrE0nSthpbvI12QWibUZV6wsiOsCeDGEvQxjJDL8Jy5PyGlEsSzN2LxHjH7Lz9LWfxodMZjG7ybtpzK4f0YT2VuGufXLb6vCqLAOXiA4K7qgIFzdylFLoi3joAHpK0KFExHquUhoxn-36OhC6GUg0kM3Ej5PEklpp1AC_4azBVJZnegNYw6LPq3DjKCEuMimTWAa-sONY4vttXYMDlFpYbateOIiYCzukm0aUYSXKGjhmHUNV8ZtTmY3uL734sNdLye_xS_ttoyIjw6Ixe0SmVoO94WNcPgq-yEznfWrjukGAcNUb34ao9IXfRM2uwXqpfsNBCSLyR3dy8x8i2YJZQSjEFtwOtmGqeOvrHcRQRbQ72DgfNVgW1A |
linkProvider | American Chemical Society |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LT-MwEB7xOAAHFtiFLcuCkbgg4ZI4zeuIqq0KtAiJh7hFjuOICDbZJemFX89MGoeHVCFukWNb4_E48zljfwNwQCRywlI2d9Bb8J4QIZeWUJzu6QoHAWqq6Yf--MIb3vTO7ty7OXDNXRgUosSeyjqI_8ouYB9TmUTd4lD-dv3YcnzHm4dFxCOCDPukf9UGD2hDahLlUVzV3Jib0Qv5JVW-90szwGbtdAbf4LYVtz5r8tCdVHFXPX9gcvzyeNZgtYGh7GRqN-swp_MNWOqb7G8bsPKGqPA7ZH35FBc5G9D5EnZamNubbIzYm1EO-4poD7AlQxDMEFQyw3bCinT6jJiWZTm7lYj4j9go-z_JkiMm84RdFY9Zwi7v0aGWP-Bm8Oe6P-RNkgYuEStU3FExTnXsKKVwZ-LjdtBXgo4oIvLzlNKIAG0v0KHQbijRXbppkKSpJbXSaA9Bz9mEhbzI9U9gPYs-tsJL4pSYyaRMExkGwk4Sif3bugOHqLWoWWRlVMfPhR1RoVFl1KiyA46Zzkg1bOeUdOPxk1a8bfVvyvbxSf0dYylvxCKZfaJW68B--xqnj0IxMtfFhOp4XhgiePVn1yFifRG4XoB1tqZW2AoliNYfN5fbX1DJHiwNr8ejaHR6cf4LlgXhE1twO9yBheppon8juqri3XotvQCiax81 |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LT-MwEB6xILFw4LU8urBgJC5IuCROm8cRFSreQuIhxCVybEdEQAIkvfDrdyZNooJUod1b5NjWeDzOfM7Y3wDsEImcsJTNHfQWvCNEwKUlFKd7usJBgBob-qF_ceke33ZO77v3I6m-UIgce8rLID6t6lcdVwwD9j6VS9QvDuel7UWW4znuD5iiyB0Z90Hvugkg0Ka0TpZHsdX61tyYXsg3qfyzbxoDOEvH05-Hh0bk8rzJU3tQRG318YXN8b_GtABzFRxlB0P7WYQJky7Bz16dBW4JZkcIC39B0pPvUZayPp0zYSdZfYuTXSAGZ5TLviD6A2zJEAwzBJesZj1hWTx8RmzLkpTdSUT-e-w8eRskeo_JVLPr7DnR7OoRHWu-DLf9o5veMa-SNXCJmKHgjopwyiNHKYU7FA-3hZ4SdFQREaCrlEEkaLu-CYTpBhLdZjf2dRxb0iiDduF3nBWYTLPUrAHrWPTRFa6OYmIokzLWMvCFrbXE_m3Tgl3UWlgttjws4-jCDqmwVmVYqbIFTj2loapYzyn5xvM3rXjT6nXI-vFN_Y3aWkbEIpk9olhrwXbzGqePQjIyNdmA6rhuECCI9cbXIYJ94XddH-usDi2xEUoQvT9uMn__g0q2YPrqsB-en1yercOMIJhiC24HGzBZvA_MHwRZRbRZLqe_0kIhuA |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Carbon+Fiber+Ionization+Mass+Spectrometry+for+the+Analysis+of+Analytes+in+Vapor%2C+Liquid%2C+and+Solid+Phases&rft.jtitle=Analytical+chemistry+%28Washington%29&rft.au=Wu%2C+Min-Li&rft.au=Chen%2C+Te-Yu&rft.au=Chen%2C+Yen-Chun&rft.au=Chen%2C+Yu-Chie&rft.date=2017-12-19&rft.eissn=1520-6882&rft.volume=89&rft.issue=24&rft.spage=13458&rft_id=info:doi/10.1021%2Facs.analchem.7b03736&rft_id=info%3Apmid%2F29155550&rft.externalDocID=29155550 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0003-2700&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0003-2700&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0003-2700&client=summon |