Automated Ptosis Measurements From Facial Photographs
Measurements of the margin reflex distances 1 and 2 are crucial for the surgical planning of ptosis repair and blepharoplasty. Facial photographs annotated with automated measurements of eyelid position could provide objective, accurate, and reproducible documentation of these features. To describe...
Saved in:
Published in | JAMA ophthalmology Vol. 134; no. 2; p. 146 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
United States
01.02.2016
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | Measurements of the margin reflex distances 1 and 2 are crucial for the surgical planning of ptosis repair and blepharoplasty. Facial photographs annotated with automated measurements of eyelid position could provide objective, accurate, and reproducible documentation of these features.
To describe a software algorithm for determining the margin reflex distances 1 and 2 from facial photographs and to evaluate its agreement with manual measurements of the margin reflex distances 1 and 2.
Observational study at a single-surgeon oculoplastic private practice among 55 eyes of 28 adult volunteers. The study dates were July 30, 2014, to September 12, 2014. The dates of our analysis were October 12, 2014, to June 18, 2015.
Agreement between manual and automated measurements of the margin reflex distances 1 and 2.
Among 55 eyes of 28 participants, automated margin reflex distance 1 measurements were strongly correlated with manual measurements (r = 0.97; 95% CI, r = 0.95 to r = 0.98; P < .001). The bias of automated margin reflex distance 1 measurements was 0.03 mm (95% CI, -0.06 to 0.12 mm), with 95% confidence limits of -0.66 and 0.71 mm. Automated margin reflex distance 2 measurements were strongly correlated with manual measurements (r = 0.96; 95% CI, r = 0.93 to r = 0.98; P < .001). The bias of automated margin reflex distance 2 measurements was 0.13 mm (95% CI, 0.03-0.22 mm), with 95% confidence limits of -0.54 and 0.80 mm.
Automated ptosis measurements produced by our software algorithm compare favorably with manually performed clinical measurements. An automated, photography-based system could provide an archival and highly reproducible means for obtaining the margin reflex distances 1 and 2 and other facial morphometric data. |
---|---|
AbstractList | Measurements of the margin reflex distances 1 and 2 are crucial for the surgical planning of ptosis repair and blepharoplasty. Facial photographs annotated with automated measurements of eyelid position could provide objective, accurate, and reproducible documentation of these features.
To describe a software algorithm for determining the margin reflex distances 1 and 2 from facial photographs and to evaluate its agreement with manual measurements of the margin reflex distances 1 and 2.
Observational study at a single-surgeon oculoplastic private practice among 55 eyes of 28 adult volunteers. The study dates were July 30, 2014, to September 12, 2014. The dates of our analysis were October 12, 2014, to June 18, 2015.
Agreement between manual and automated measurements of the margin reflex distances 1 and 2.
Among 55 eyes of 28 participants, automated margin reflex distance 1 measurements were strongly correlated with manual measurements (r = 0.97; 95% CI, r = 0.95 to r = 0.98; P < .001). The bias of automated margin reflex distance 1 measurements was 0.03 mm (95% CI, -0.06 to 0.12 mm), with 95% confidence limits of -0.66 and 0.71 mm. Automated margin reflex distance 2 measurements were strongly correlated with manual measurements (r = 0.96; 95% CI, r = 0.93 to r = 0.98; P < .001). The bias of automated margin reflex distance 2 measurements was 0.13 mm (95% CI, 0.03-0.22 mm), with 95% confidence limits of -0.54 and 0.80 mm.
Automated ptosis measurements produced by our software algorithm compare favorably with manually performed clinical measurements. An automated, photography-based system could provide an archival and highly reproducible means for obtaining the margin reflex distances 1 and 2 and other facial morphometric data. |
Author | Bodnar, Zachary M Holds, John B Neimkin, Michael |
Author_xml | – sequence: 1 givenname: Zachary M surname: Bodnar fullname: Bodnar, Zachary M organization: Department of Ophthalmology, Saint Louis University, St Louis, Missouri – sequence: 2 givenname: Michael surname: Neimkin fullname: Neimkin, Michael organization: Department of Ophthalmology and Visual Sciences, Washington University in St Louis, St Louis, Missouri – sequence: 3 givenname: John B surname: Holds fullname: Holds, John B organization: Department of Ophthalmology, Saint Louis University, St Louis, Missouri |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/26605967$$D View this record in MEDLINE/PubMed |
BookMark | eNo1jstOwzAUBS0EoqX0F5B_IMHXr6TLqiKAVEQX7bq6dhySKo6j2Fnw91QCzmY0m9F5ILdDGBwhFFgOjMHzBT2GsU0t9j70OWegcqlB3pAlB11mGgqxIOsYL-y6kjEp1D1ZcK2Z2uhiSdR2TsFjcjU9pBC7SD8cxnly3g0p0moKnlZoO-zpoQ0pfE04tvGR3DXYR7f-44qcqpfj7i3bf76-77b7DEUpU8a5kVIZMFgqaJyoreNSQG2UlY0tpK0Lzq8GG-OMZkYLJ7XGwqCxpdScr8jTb3ecjXf1eZw6j9P3-f8__wG7fkye |
CitedBy_id | crossref_primary_10_1016_j_ajo_2021_05_007 crossref_primary_10_1111_aos_13437 crossref_primary_10_1007_s10792_023_02899_5 crossref_primary_10_1097_IOP_0000000000001059 crossref_primary_10_1097_GOX_0000000000003089 crossref_primary_10_1177_11206721211049057 crossref_primary_10_2196_32444 crossref_primary_10_1007_s44162_023_00020_z crossref_primary_10_1097_SCS_0000000000003558 crossref_primary_10_1080_02713683_2019_1619779 crossref_primary_10_3390_jcm12237466 crossref_primary_10_1080_07853890_2021_2009127 crossref_primary_10_1159_000531224 crossref_primary_10_1186_s12880_024_01280_x crossref_primary_10_54461_JAcupotomy_2024_8_1_38 crossref_primary_10_1016_j_jaapos_2021_05_020 crossref_primary_10_1097_IOP_0000000000002117 crossref_primary_10_3390_jpm12020283 crossref_primary_10_1080_02713683_2021_1908569 crossref_primary_10_1016_j_imed_2022_08_003 crossref_primary_10_1038_s41598_024_51838_6 crossref_primary_10_1186_s12886_021_01923_5 crossref_primary_10_1097_WNO_0000000000001451 crossref_primary_10_1177_11206721241249773 crossref_primary_10_1016_j_disamonth_2020_101026 crossref_primary_10_1111_jocd_14361 crossref_primary_10_1097_PRS_0000000000009329 crossref_primary_10_1093_asj_sjad070 crossref_primary_10_1007_s10792_021_02110_7 |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1001/jamaophthalmol.2015.4614 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 2168-6173 |
ExternalDocumentID | 26605967 |
Genre | Journal Article Comparative Study Observational Study |
GroupedDBID | 0R~ 4.4 53G AAWTL ABJNI ACGFS ACNCT ACPRK ADBBV AENEX AFOSN AHMBA ALMA_UNASSIGNED_HOLDINGS AMJDE ANMPU BCGUY BRYMA C45 CGR CUY CVF EBD EBS ECM EIF EJD EMOBN EX3 H13 NPM OB3 OBH OGROG OHH OVD PQQKQ RAJ SV3 TEORI WOW |
ID | FETCH-LOGICAL-a384t-22b445b1ba851fe3dce2431db5c4fc74cd722db519beb60b63e466a7babc84622 |
IngestDate | Sat Sep 28 08:02:52 EDT 2024 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 2 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-a384t-22b445b1ba851fe3dce2431db5c4fc74cd722db519beb60b63e466a7babc84622 |
OpenAccessLink | https://jamanetwork.com/journals/jamaophthalmology/articlepdf/2473361/eoi150097.pdf |
PMID | 26605967 |
ParticipantIDs | pubmed_primary_26605967 |
PublicationCentury | 2000 |
PublicationDate | 2016-02-01 |
PublicationDateYYYYMMDD | 2016-02-01 |
PublicationDate_xml | – month: 02 year: 2016 text: 2016-02-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | JAMA ophthalmology |
PublicationTitleAlternate | JAMA Ophthalmol |
PublicationYear | 2016 |
SSID | ssj0000800435 |
Score | 2.3755865 |
Snippet | Measurements of the margin reflex distances 1 and 2 are crucial for the surgical planning of ptosis repair and blepharoplasty. Facial photographs annotated... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 146 |
SubjectTerms | Adult Aged Aged, 80 and over Algorithms Blepharoptosis - diagnosis Blinking Diagnostic Techniques, Ophthalmological Face Female Humans Male Middle Aged Photography - methods Reproducibility of Results Software Young Adult |
Title | Automated Ptosis Measurements From Facial Photographs |
URI | https://www.ncbi.nlm.nih.gov/pubmed/26605967 |
Volume | 134 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LS8NAEF6qgngR32_JwVuJmM1mNz1WUVRo6aGCeJGdzYYqtik0Peivdza7bdJa8XEJyS4s2XzJ5JvhmxlCzgKAMFVU-YHm6KCINPaB8RRdlUQGkRIgihIbrTa_fWD3j9FjrXZXUS2NczhXHwvzSv6DKo4hriZL9g_IThfFATxHfPGICOPxVxg3x3mGjBM5YyfPTGWRVhnxGyEnzfr1G1nExDu9LLfFqUczdBRNbj0b9vKefOvPBNgvs2RgtddP0mRmvZdh07Z-6bsmXlXRvc1vSEYTga_r5-wiCsFUhGx-CIXloQGPTe5gOGMmXdDxpeKuWqPngohfjHHZBKDciBHTReeM28zRCkbDfgES8gXTEEj8PDtXJnsytUSWRGwMXtuFbV4dLUZe6JRck6pTi-7KFId2K805GgXh6G6QdecpeE0L-yap6cEWWW05LcQ2iaboexZ9r4q-Z9D3LPpeBf0d8nBz3b269V0TDF-GMct9SoGxCAKQyI1THSZKUyR9CUSKpUowlQhK8SpogAZ-ATzUjHMpQIJCbknpLlkeZAO9TzwpJDI2dEGDRowsOokTGTc05QKUUCmkB2TPbvh5aCudPE8exeG3M0dkrXyFjslKip-WPkGelsNpgcEnp3c9xw |
link.rule.ids | 783 |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Automated+Ptosis+Measurements+From+Facial+Photographs&rft.jtitle=JAMA+ophthalmology&rft.au=Bodnar%2C+Zachary+M&rft.au=Neimkin%2C+Michael&rft.au=Holds%2C+John+B&rft.date=2016-02-01&rft.eissn=2168-6173&rft.volume=134&rft.issue=2&rft.spage=146&rft_id=info:doi/10.1001%2Fjamaophthalmol.2015.4614&rft_id=info%3Apmid%2F26605967&rft_id=info%3Apmid%2F26605967&rft.externalDocID=26605967 |