Automated Ptosis Measurements From Facial Photographs

Measurements of the margin reflex distances 1 and 2 are crucial for the surgical planning of ptosis repair and blepharoplasty. Facial photographs annotated with automated measurements of eyelid position could provide objective, accurate, and reproducible documentation of these features. To describe...

Full description

Saved in:
Bibliographic Details
Published inJAMA ophthalmology Vol. 134; no. 2; p. 146
Main Authors Bodnar, Zachary M, Neimkin, Michael, Holds, John B
Format Journal Article
LanguageEnglish
Published United States 01.02.2016
Subjects
Online AccessGet more information

Cover

Loading…
Abstract Measurements of the margin reflex distances 1 and 2 are crucial for the surgical planning of ptosis repair and blepharoplasty. Facial photographs annotated with automated measurements of eyelid position could provide objective, accurate, and reproducible documentation of these features. To describe a software algorithm for determining the margin reflex distances 1 and 2 from facial photographs and to evaluate its agreement with manual measurements of the margin reflex distances 1 and 2. Observational study at a single-surgeon oculoplastic private practice among 55 eyes of 28 adult volunteers. The study dates were July 30, 2014, to September 12, 2014. The dates of our analysis were October 12, 2014, to June 18, 2015. Agreement between manual and automated measurements of the margin reflex distances 1 and 2. Among 55 eyes of 28 participants, automated margin reflex distance 1 measurements were strongly correlated with manual measurements (r = 0.97; 95% CI, r = 0.95 to r = 0.98; P < .001). The bias of automated margin reflex distance 1 measurements was 0.03 mm (95% CI, -0.06 to 0.12 mm), with 95% confidence limits of -0.66 and 0.71 mm. Automated margin reflex distance 2 measurements were strongly correlated with manual measurements (r = 0.96; 95% CI, r = 0.93 to r = 0.98; P < .001). The bias of automated margin reflex distance 2 measurements was 0.13 mm (95% CI, 0.03-0.22 mm), with 95% confidence limits of -0.54 and 0.80 mm. Automated ptosis measurements produced by our software algorithm compare favorably with manually performed clinical measurements. An automated, photography-based system could provide an archival and highly reproducible means for obtaining the margin reflex distances 1 and 2 and other facial morphometric data.
AbstractList Measurements of the margin reflex distances 1 and 2 are crucial for the surgical planning of ptosis repair and blepharoplasty. Facial photographs annotated with automated measurements of eyelid position could provide objective, accurate, and reproducible documentation of these features. To describe a software algorithm for determining the margin reflex distances 1 and 2 from facial photographs and to evaluate its agreement with manual measurements of the margin reflex distances 1 and 2. Observational study at a single-surgeon oculoplastic private practice among 55 eyes of 28 adult volunteers. The study dates were July 30, 2014, to September 12, 2014. The dates of our analysis were October 12, 2014, to June 18, 2015. Agreement between manual and automated measurements of the margin reflex distances 1 and 2. Among 55 eyes of 28 participants, automated margin reflex distance 1 measurements were strongly correlated with manual measurements (r = 0.97; 95% CI, r = 0.95 to r = 0.98; P < .001). The bias of automated margin reflex distance 1 measurements was 0.03 mm (95% CI, -0.06 to 0.12 mm), with 95% confidence limits of -0.66 and 0.71 mm. Automated margin reflex distance 2 measurements were strongly correlated with manual measurements (r = 0.96; 95% CI, r = 0.93 to r = 0.98; P < .001). The bias of automated margin reflex distance 2 measurements was 0.13 mm (95% CI, 0.03-0.22 mm), with 95% confidence limits of -0.54 and 0.80 mm. Automated ptosis measurements produced by our software algorithm compare favorably with manually performed clinical measurements. An automated, photography-based system could provide an archival and highly reproducible means for obtaining the margin reflex distances 1 and 2 and other facial morphometric data.
Author Bodnar, Zachary M
Holds, John B
Neimkin, Michael
Author_xml – sequence: 1
  givenname: Zachary M
  surname: Bodnar
  fullname: Bodnar, Zachary M
  organization: Department of Ophthalmology, Saint Louis University, St Louis, Missouri
– sequence: 2
  givenname: Michael
  surname: Neimkin
  fullname: Neimkin, Michael
  organization: Department of Ophthalmology and Visual Sciences, Washington University in St Louis, St Louis, Missouri
– sequence: 3
  givenname: John B
  surname: Holds
  fullname: Holds, John B
  organization: Department of Ophthalmology, Saint Louis University, St Louis, Missouri
BackLink https://www.ncbi.nlm.nih.gov/pubmed/26605967$$D View this record in MEDLINE/PubMed
BookMark eNo1jstOwzAUBS0EoqX0F5B_IMHXr6TLqiKAVEQX7bq6dhySKo6j2Fnw91QCzmY0m9F5ILdDGBwhFFgOjMHzBT2GsU0t9j70OWegcqlB3pAlB11mGgqxIOsYL-y6kjEp1D1ZcK2Z2uhiSdR2TsFjcjU9pBC7SD8cxnly3g0p0moKnlZoO-zpoQ0pfE04tvGR3DXYR7f-44qcqpfj7i3bf76-77b7DEUpU8a5kVIZMFgqaJyoreNSQG2UlY0tpK0Lzq8GG-OMZkYLJ7XGwqCxpdScr8jTb3ecjXf1eZw6j9P3-f8__wG7fkye
CitedBy_id crossref_primary_10_1016_j_ajo_2021_05_007
crossref_primary_10_1111_aos_13437
crossref_primary_10_1007_s10792_023_02899_5
crossref_primary_10_1097_IOP_0000000000001059
crossref_primary_10_1097_GOX_0000000000003089
crossref_primary_10_1177_11206721211049057
crossref_primary_10_2196_32444
crossref_primary_10_1007_s44162_023_00020_z
crossref_primary_10_1097_SCS_0000000000003558
crossref_primary_10_1080_02713683_2019_1619779
crossref_primary_10_3390_jcm12237466
crossref_primary_10_1080_07853890_2021_2009127
crossref_primary_10_1159_000531224
crossref_primary_10_1186_s12880_024_01280_x
crossref_primary_10_54461_JAcupotomy_2024_8_1_38
crossref_primary_10_1016_j_jaapos_2021_05_020
crossref_primary_10_1097_IOP_0000000000002117
crossref_primary_10_3390_jpm12020283
crossref_primary_10_1080_02713683_2021_1908569
crossref_primary_10_1016_j_imed_2022_08_003
crossref_primary_10_1038_s41598_024_51838_6
crossref_primary_10_1186_s12886_021_01923_5
crossref_primary_10_1097_WNO_0000000000001451
crossref_primary_10_1177_11206721241249773
crossref_primary_10_1016_j_disamonth_2020_101026
crossref_primary_10_1111_jocd_14361
crossref_primary_10_1097_PRS_0000000000009329
crossref_primary_10_1093_asj_sjad070
crossref_primary_10_1007_s10792_021_02110_7
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1001/jamaophthalmol.2015.4614
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
EISSN 2168-6173
ExternalDocumentID 26605967
Genre Journal Article
Comparative Study
Observational Study
GroupedDBID 0R~
4.4
53G
AAWTL
ABJNI
ACGFS
ACNCT
ACPRK
ADBBV
AENEX
AFOSN
AHMBA
ALMA_UNASSIGNED_HOLDINGS
AMJDE
ANMPU
BCGUY
BRYMA
C45
CGR
CUY
CVF
EBD
EBS
ECM
EIF
EJD
EMOBN
EX3
H13
NPM
OB3
OBH
OGROG
OHH
OVD
PQQKQ
RAJ
SV3
TEORI
WOW
ID FETCH-LOGICAL-a384t-22b445b1ba851fe3dce2431db5c4fc74cd722db519beb60b63e466a7babc84622
IngestDate Sat Sep 28 08:02:52 EDT 2024
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 2
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-a384t-22b445b1ba851fe3dce2431db5c4fc74cd722db519beb60b63e466a7babc84622
OpenAccessLink https://jamanetwork.com/journals/jamaophthalmology/articlepdf/2473361/eoi150097.pdf
PMID 26605967
ParticipantIDs pubmed_primary_26605967
PublicationCentury 2000
PublicationDate 2016-02-01
PublicationDateYYYYMMDD 2016-02-01
PublicationDate_xml – month: 02
  year: 2016
  text: 2016-02-01
  day: 01
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle JAMA ophthalmology
PublicationTitleAlternate JAMA Ophthalmol
PublicationYear 2016
SSID ssj0000800435
Score 2.3755865
Snippet Measurements of the margin reflex distances 1 and 2 are crucial for the surgical planning of ptosis repair and blepharoplasty. Facial photographs annotated...
SourceID pubmed
SourceType Index Database
StartPage 146
SubjectTerms Adult
Aged
Aged, 80 and over
Algorithms
Blepharoptosis - diagnosis
Blinking
Diagnostic Techniques, Ophthalmological
Face
Female
Humans
Male
Middle Aged
Photography - methods
Reproducibility of Results
Software
Young Adult
Title Automated Ptosis Measurements From Facial Photographs
URI https://www.ncbi.nlm.nih.gov/pubmed/26605967
Volume 134
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LS8NAEF6qgngR32_JwVuJmM1mNz1WUVRo6aGCeJGdzYYqtik0Peivdza7bdJa8XEJyS4s2XzJ5JvhmxlCzgKAMFVU-YHm6KCINPaB8RRdlUQGkRIgihIbrTa_fWD3j9FjrXZXUS2NczhXHwvzSv6DKo4hriZL9g_IThfFATxHfPGICOPxVxg3x3mGjBM5YyfPTGWRVhnxGyEnzfr1G1nExDu9LLfFqUczdBRNbj0b9vKefOvPBNgvs2RgtddP0mRmvZdh07Z-6bsmXlXRvc1vSEYTga_r5-wiCsFUhGx-CIXloQGPTe5gOGMmXdDxpeKuWqPngohfjHHZBKDciBHTReeM28zRCkbDfgES8gXTEEj8PDtXJnsytUSWRGwMXtuFbV4dLUZe6JRck6pTi-7KFId2K805GgXh6G6QdecpeE0L-yap6cEWWW05LcQ2iaboexZ9r4q-Z9D3LPpeBf0d8nBz3b269V0TDF-GMct9SoGxCAKQyI1THSZKUyR9CUSKpUowlQhK8SpogAZ-ATzUjHMpQIJCbknpLlkeZAO9TzwpJDI2dEGDRowsOokTGTc05QKUUCmkB2TPbvh5aCudPE8exeG3M0dkrXyFjslKip-WPkGelsNpgcEnp3c9xw
link.rule.ids 783
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Automated+Ptosis+Measurements+From+Facial+Photographs&rft.jtitle=JAMA+ophthalmology&rft.au=Bodnar%2C+Zachary+M&rft.au=Neimkin%2C+Michael&rft.au=Holds%2C+John+B&rft.date=2016-02-01&rft.eissn=2168-6173&rft.volume=134&rft.issue=2&rft.spage=146&rft_id=info:doi/10.1001%2Fjamaophthalmol.2015.4614&rft_id=info%3Apmid%2F26605967&rft_id=info%3Apmid%2F26605967&rft.externalDocID=26605967