A genetic algorithm based multi-objective shape optimization scheme for cementless femoral implant
The shape and geometry of femoral implant influence implant-induced periprosthetic bone resorption and implant-bone interface stresses, which are potential causes of aseptic loosening in cementless total hip arthroplasty (THA). Development of a shape optimization scheme is necessary to achieve a tra...
Saved in:
Published in | Journal of biomechanical engineering Vol. 137; no. 3 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
United States
01.03.2015
|
Subjects | |
Online Access | Get more information |
ISSN | 1528-8951 |
DOI | 10.1115/1.4029061 |
Cover
Loading…
Abstract | The shape and geometry of femoral implant influence implant-induced periprosthetic bone resorption and implant-bone interface stresses, which are potential causes of aseptic loosening in cementless total hip arthroplasty (THA). Development of a shape optimization scheme is necessary to achieve a trade-off between these two conflicting objectives. The objective of this study was to develop a novel multi-objective custom-based shape optimization scheme for cementless femoral implant by integrating finite element (FE) analysis and a multi-objective genetic algorithm (GA). The FE model of a proximal femur was based on a subject-specific CT-scan dataset. Eighteen parameters describing the nature of four key sections of the implant were identified as design variables. Two objective functions, one based on implant-bone interface failure criterion, and the other based on resorbed proximal bone mass fraction (BMF), were formulated. The results predicted by the two objective functions were found to be contradictory; a reduction in the proximal bone resorption was accompanied by a greater chance of interface failure. The resorbed proximal BMF was found to be between 23% and 27% for the trade-off geometries as compared to ∼39% for a generic implant. Moreover, the overall chances of interface failure have been minimized for the optimal designs, compared to the generic implant. The adaptive bone remodeling was also found to be minimal for the optimally designed implants and, further with remodeling, the chances of interface debonding increased only marginally. |
---|---|
AbstractList | The shape and geometry of femoral implant influence implant-induced periprosthetic bone resorption and implant-bone interface stresses, which are potential causes of aseptic loosening in cementless total hip arthroplasty (THA). Development of a shape optimization scheme is necessary to achieve a trade-off between these two conflicting objectives. The objective of this study was to develop a novel multi-objective custom-based shape optimization scheme for cementless femoral implant by integrating finite element (FE) analysis and a multi-objective genetic algorithm (GA). The FE model of a proximal femur was based on a subject-specific CT-scan dataset. Eighteen parameters describing the nature of four key sections of the implant were identified as design variables. Two objective functions, one based on implant-bone interface failure criterion, and the other based on resorbed proximal bone mass fraction (BMF), were formulated. The results predicted by the two objective functions were found to be contradictory; a reduction in the proximal bone resorption was accompanied by a greater chance of interface failure. The resorbed proximal BMF was found to be between 23% and 27% for the trade-off geometries as compared to ∼39% for a generic implant. Moreover, the overall chances of interface failure have been minimized for the optimal designs, compared to the generic implant. The adaptive bone remodeling was also found to be minimal for the optimally designed implants and, further with remodeling, the chances of interface debonding increased only marginally. |
Author | Kumar Pratihar, Dilip Gupta, Sanjay Chanda, Souptick |
Author_xml | – sequence: 1 givenname: Souptick surname: Chanda fullname: Chanda, Souptick – sequence: 2 givenname: Sanjay surname: Gupta fullname: Gupta, Sanjay – sequence: 3 givenname: Dilip surname: Kumar Pratihar fullname: Kumar Pratihar, Dilip |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/25392855$$D View this record in MEDLINE/PubMed |
BookMark | eNo1j81KxDAURoMozo8ufAHJC3TMTZM2XQ6DfzDgRtfDTXo7k6FpSpMR9OlV1NV3NufAt2DnQxyIsRsQKwDQd7BSQjaigjM2By1NYRoNM7ZI6SgEgFHiks2kLhtptJ4zu-Z7Gih7x7Hfx8nnQ-AWE7U8nPrsi2iP5LJ_J54OOBKPY_bBf2L2ceDJHSgQ7-LE3TcMuaeUeEchTthzH8Yeh3zFLjrsE13_7ZK9Pdy_bp6K7cvj82a9LbCsIRe2JDCN6pqKytKSarDETlbOUmVVXQvt0Ija6NYRVca1qBQhaCtI4I8il-z2tzuebKB2N04-4PSx-z8rvwCJ_Fd5 |
CitedBy_id | crossref_primary_10_1177_0954411919890998 crossref_primary_10_1016_j_medengphy_2024_104159 crossref_primary_10_1080_10255842_2025_2466225 crossref_primary_10_1002_cnm_3637 crossref_primary_10_1039_D3TB01469J crossref_primary_10_1080_10255842_2019_1661387 crossref_primary_10_1007_s40032_020_00611_5 crossref_primary_10_1016_j_jmbbm_2021_104903 crossref_primary_10_1115_1_4035368 crossref_primary_10_1016_j_asoc_2015_10_020 crossref_primary_10_1115_1_4035481 crossref_primary_10_1038_s41598_018_36503_z crossref_primary_10_1016_j_compbiomed_2020_103937 crossref_primary_10_1080_10255842_2023_2301676 crossref_primary_10_3390_ma16030974 crossref_primary_10_3390_ma17215305 crossref_primary_10_1007_s00158_015_1382_1 crossref_primary_10_1115_1_4031938 crossref_primary_10_3390_jcm12226962 crossref_primary_10_1007_s10237_021_01436_6 crossref_primary_10_1016_j_compbiomed_2016_06_016 crossref_primary_10_1177_09544119241244537 crossref_primary_10_1016_j_arth_2015_07_036 crossref_primary_10_1016_j_jmbbm_2017_10_019 crossref_primary_10_1002_cnm_3191 |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1115/1.4029061 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Medicine Engineering Forestry |
EISSN | 1528-8951 |
ExternalDocumentID | 25392855 |
Genre | Journal Article |
GroupedDBID | --- -~X .DC .GJ 29J 4.4 53G 5AI 5GY 6TJ AAYJJ ABJNI ACBEA ACGFO ACGFS ACKMT ACXMS ADPDT AI. ALEEW ALMA_UNASSIGNED_HOLDINGS CGR CS3 CUY CVF EBS ECM EIF EJD F5P H~9 L7B NPM P2P RAI RNS RXW TAE TN5 UCJ UKR VH1 VXZ WHG ZE2 |
ID | FETCH-LOGICAL-a371t-b3e1894f96e33be49a3af26cbe6b47705ca80785dcee68cda44ea15b0e0a6e332 |
IngestDate | Wed Feb 19 01:53:01 EST 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 3 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-a371t-b3e1894f96e33be49a3af26cbe6b47705ca80785dcee68cda44ea15b0e0a6e332 |
PMID | 25392855 |
ParticipantIDs | pubmed_primary_25392855 |
PublicationCentury | 2000 |
PublicationDate | 2015-Mar |
PublicationDateYYYYMMDD | 2015-03-01 |
PublicationDate_xml | – month: 03 year: 2015 text: 2015-Mar |
PublicationDecade | 2010 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Journal of biomechanical engineering |
PublicationTitleAlternate | J Biomech Eng |
PublicationYear | 2015 |
SSID | ssj0011840 |
Score | 2.267205 |
Snippet | The shape and geometry of femoral implant influence implant-induced periprosthetic bone resorption and implant-bone interface stresses, which are potential... |
SourceID | pubmed |
SourceType | Index Database |
SubjectTerms | Algorithms Femur - diagnostic imaging Finite Element Analysis Prostheses and Implants Prosthesis Design - methods Tomography, X-Ray Computed |
Title | A genetic algorithm based multi-objective shape optimization scheme for cementless femoral implant |
URI | https://www.ncbi.nlm.nih.gov/pubmed/25392855 |
Volume | 137 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Nb9NAEF3RIiF6qEqBflG0B26Rg9def-wxamkjJDi1Um_V7npMqGI7UtNLf31ndjexiSgCLmvHKyeW3_NkZzzzhrFPBpJYGllEcamKSBphI61wUEWWV4IE46xLkP2eT6_l15vspk8dctUlSzO2j7-tK_kfVPEY4kpVsv-A7PpL8QDuI744IsI4_hXGE2qADE5ydf6jQzd_1ozob6nyeYJRZ-68PRvdz_QCRh3ahyYUXo7QrYXGS35bFyOck9GrKfOWhDiaxVy3vwTuB2tXV7RPNcMOYug1DQfZAujru9Bq94C_atcFQZf40U_o9q7P4HGp3qSetPw58znf5xTpGQYlRNZnZY0hGNKkjEoVxGRXltbruwRKpc9YcBK7EGP0a1XsddoHSC4aB2WS4bKu9Pq-f57dENNeTW2xLXQrqE8qBXfCSydydoP4FF7F5_U1kGB0OG_D-XCLkKs9thsQ4BNPhTfsBbT7bGegKbnPXlGzVergh7vfQuLEW2YmPFCFr6nCHVX4BlW4owofUoV7qnCkCu-pwgNVeKDKO3Z98eXqbBqF9hqRTguxjEwKolSyVjmkqQGpdKrrJLcGcnx4izizmpoRZBWuo_LSVlpK0CIzMcSaTknes-22a-GQcXTkIdMlOr_onkoBuBVlUSuRVmArWR2xA3_bbhdeQ-V2dUOPn505Ya97Zn1gL2t8aOEUV4BL89Hh9gRyemAF |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=A+genetic+algorithm+based+multi-objective+shape+optimization+scheme+for+cementless+femoral+implant&rft.jtitle=Journal+of+biomechanical+engineering&rft.au=Chanda%2C+Souptick&rft.au=Gupta%2C+Sanjay&rft.au=Kumar+Pratihar%2C+Dilip&rft.date=2015-03-01&rft.eissn=1528-8951&rft.volume=137&rft.issue=3&rft_id=info:doi/10.1115%2F1.4029061&rft_id=info%3Apmid%2F25392855&rft_id=info%3Apmid%2F25392855&rft.externalDocID=25392855 |